GPC50FG

GPC50FG Datasheet


GPC50 Commercial

Part Datasheet
GPC50FG GPC50FG GPC50FG (pdf)
Related Parts Information
GPC50A GPC50A GPC50A
GPC50F GPC50F GPC50F
GPC50BG GPC50BG GPC50BG
GPC50AG GPC50AG GPC50AG
PDF Datasheet Preview
GLOBAL PERFORMANCE SWITCHERS

GPC50 Commercial
50 WATT GLOBAL PERFORMANCE SWITCHERS

Summary:
• Wide-range ac input 85-264 Vac
• 2-year warranty
• Approved to UL1950, IEC950 and CSA22.2-234 L3
• Meets FCC and CISPR22 Class B conducted emissions requirements
• Triple outputs
• RoHS Compliant Model Availalbe G suffix
• marked to LVD

SPECIFICATIONS

Ac Input 85-264 Vac, 47-63 Hz single phase.

Input Current Maximum input current at 120 Vac, 60 Hz with full rated output load A

Hold-Up Time 20 ms minimum from loss of ac input at full load, nominal line 115 Vac .

Output Power 50 W continuous, 60 W peak. Peak ratings are for 60 s maximum duration, 10% duty cycle. During peak load condition, output regulation may exceed total regulation limits.

Overload Protection Fully protected against short circuit and output overload. Short circuit protection is cycling type power limit on outputs 1 & 2 foldback type on output Recovery after fault is automatic. See output ratings chart for additional notes or conditions.

Overvoltage Protection. Crowbar provided on V1.

Efficiency 65% at full rated load, nominal input voltage, depending on model and load distribution.

Turn-on Time Less than 1 second at 120 Vac, 25°C inversely proportional to input voltage and thermistor temperature .

Input Protection Internal ac fuse provided. Designed to blow only if a catastrophic failure occurs in the unit.

Inrush Current Inrush is limited by internal thermistors. Inrush at 240 Vac under cold start conditions will not exceed 34 A.

Temperature Coefficient 0.03%/°C typical on all outputs.

Environmental Designed for 0 to 50°C operation at full rated output power derate output current and total output power by per °C above 50°C. See Environmental and Packaging Specifications on next page.

Output Noise rms, 1% pk-pk, 20 MHz bandwidth, differential mode. Measured with noise probe directly across output terminals of the power supply.

Transient Response Main us typical response time for return to within of final value for a 50% load step change. A/us. Maximum voltage deviation is Startup/ shutdown overshoot less than

Voltage Adjustment Built-in potentiometer adjusts voltage ±5% on outputs 1 &

EMI/EMC Compliance All models include built-in EMI filtering to meet the following emissions requirements:

EMI SPECIFICATIONS

Conducted Emissions Static Discharge RF Field Susceptibility Fast Transients/Bursts Surge Susceptibility

COMPLIANCE LEVEL

EN55022 Class B FCC Class B EN61000-4-2, 6 kV contact, 8 kV air EN61000-4-3, 3 V/meter EN61000-4-4, 2 kV, 5 kH EN61000-4-5, 1 kV diff., 2 kV com.

Leakage Current mA 254 Vac 60 Hz input.

Safety Approved to UL1950, CSA22.2 No. 234 Level 3, IEC950 and EN60950 UL file #E135803 commercial CSA #LR46516 all models. All DC outputs are SELV under normal and single fault conditions.

All specifications are typical at nominal input, full load at 25OC unless otherwise stated

Commercial Model GPC50A

GPC50F

Output No. 1 2 3 1 2 3

Output +5 V +12 V -12 V +5 V +12 V -12 V

Output Minimum

A 0A A 0A

Output Maximum
5A 2A A 5A A

Output Peak 7A 3A 1A 7A A 1A

Noise P-P 50 mV 120 mV 120 mV 50 mV 120 mV 120 mV

Total Regulation A
2% 5% 3% 2% 3% 3%
More datasheets: G2-DB01-ST | G2-DB02-TT | G2-DB02-ST | PSE1000PFC | MSA-0870 | FMG1G100US60H | GPC50A | GPC50F | GPC50BG | GPC50AG


Notice: we do not provide any warranties that information, datasheets, application notes, circuit diagrams, or software stored on this website are up-to-date or error free. The archived GPC50FG Datasheet file may be downloaded here without warranties.

Datasheet ID: GPC50FG 506320