GLC40-28

GLC40-28 Datasheet


GLC40 Commercial

Part Datasheet
GLC40-28 GLC40-28 GLC40-28 (pdf)
Related Parts Information
GLC40-24 GLC40-24 GLC40-24
GLC40-15 GLC40-15 GLC40-15
GLC40-3.3 GLC40-3.3 GLC40-3.3
GLC40-48 GLC40-48 GLC40-48
GLC40-5 GLC40-5 GLC40-5
GLC40B GLC40B GLC40B
GLC40D GLC40D GLC40D
GLC40A GLC40A GLC40A
GLC40-12 GLC40-12 GLC40-12
GLC40AG GLC40AG GLC40AG
GLC40-48G GLC40-48G GLC40-48G
GLC40-5G GLC40-5G GLC40-5G
GLC40-28G GLC40-28G GLC40-28G
GLC40-24G GLC40-24G GLC40-24G
GLC40-12G GLC40-12G GLC40-12G
GLC40DG GLC40DG GLC40DG
GLC40BG GLC40BG GLC40BG
GLC40-15G GLC40-15G GLC40-15G
GLC40-3.3G GLC40-3.3G GLC40-3.3G
PDF Datasheet Preview
GLC40 Commercial
40 WATT GLOBAL PERFORMANCE LOW COST SWITCHERS

GLOBAL PERFORMANCE SWITCHERS

Features:
• Cost-effective power source
• Universal input 90-264 Vac
• 2-year warranty
• Single and multiple outputs
• Overload and overvoltage protection
• Built-in EMI filter
• UL1950, CSA-C22.2 No. 234 Level 3,

IEC950 and EN60950
• Operation at no-load single output models
• RoHS Compliant with G suffix
• marked to LVD

SPECIFICATIONS

Ac Input 90-264 Vac, 47-63 Hz single phase.

Input Current Maximum input current at 120 Vac, 60 Hz with full rated output load not to exceed A.

Output Power Normal continuous output power is 40 W for unrestricted natural convection cooling, 45 W peak for 60 seconds. During peak load conditions output regulation may exceed total regulation and noise limits.

Output Regulation for multiple-output models measured by ±40% load change from 60% rated load with all other outputs at 60% full rated load and a line voltage change from low line to high line. Initial set tolerance is measured with all outputs at 60% of full rated load. Output voltage V1 requires 1 A load for proper regulation of multiple output models. Regulation for single-output models measured by changing from 5% to 50% load or 50% load to full load in either direction.

Power Limit Factory set to begin power limiting at approximately 55 W. Fully protected against short circuit and output overload. Short circuit protection is cycling type power limit.

Output Noise rms, 1% pk-pk, 20 MHz bandwidth, mode. Measured with noise probe terminals of the power supply.

Transient Response Main Output 500 us typical response time for return to within of final value for a 50% load step change, A/us. Maximum voltage deviation is Startup/ shutdown overshoot less than

Overvoltage Protection Built in on V1 with firing point set per table. OVP firing reduces output #1 and #2 to less than 50% of nominal voltage in 50 ms.

Voltage Setting Factory set on standard units with fixed resistors for added reliability. V unit has voltage adjustment pot.

Efficiency 70% typical depending on model.

Turn-on Time Less than 1 second at 120 Vac, 25°C inversely proportional to input voltage and thermistor temperature .

Input Protection Internal ac fuse provided on all units. Designed to blow only if a catastrophic failure occurs in the unit. Fuse does not blow on overload or short circuit.

Inrush Current Inrush limited by internal thermistors. Inrush at 240 Vac, averaged over the first ac half-cycle under cold start conditions will not exceed 37 A.

Temperature Coefficient 0.03%/°C typical on all outputs.

EMI/EMC Compliance All models include built-in EMI filtering to meet the following emissions requirements:

EMI SPECIFICATIONS

COMPLIANCE LEVEL

Conducted Emissions Static Discharge RF Field Susceptibility Fast Transients/Bursts Surge Susceptibility

EN55022 Class A FCC Class A EN61000-4-2, 6 kV contact, 8 kV air EN61000-4-3, 3 V/meter EN61000-4-4, 2 kV, 5 kHz EN61000-4-5, 1 kV diff., 2 kV com.

Safety All GLC40 models are approved to UL1950, CSA-C22.2 No. 234 Level 3, IEC950 and EN60950. Class I input.

All specifications are typical at nominal input, full load at 25OC unless otherwise stated

Commercial Model GLC40AG

GLC40BG

GLC40DG

GLC40-3.3G GLC40-5G GLC40-9G GLC40-12G GLC40-13.8G GLC40-15G GLC40-24G GLC40-28G

Output No. 1 2 3 1 2 3 1 2 3 1

Output + V + 12 V - 12 V + V + 15 V - 15 V +5 V +24 V -12 V
5V 9V 12 V 15 V 24 V 28 V

GLC40 MECHANICAL SPECIFICATIONS

Output Minimum 1A 0A 1A 0A 1A 0A

Output Maximum 3A 2A A 3A A 3A 1A A 8A A

V 1 OVP Set + ± V
+ ± V
+ ± V
More datasheets: EP9312-IB | BCM8155FAIFB | CPDVR105V0USP-HF | 76000843 | AS1151 | AS1150 | AS1150-T | AS1151-T | GLC40-24 | GLC40-15


Notice: we do not provide any warranties that information, datasheets, application notes, circuit diagrams, or software stored on this website are up-to-date or error free. The archived GLC40-28 Datasheet file may be downloaded here without warranties.

Datasheet ID: GLC40-28 506300