QHW075F1-Q

QHW075F1-Q Datasheet


QHW050F1-Q, QHW075F1-Q, and QHW100F1-Q Power Modules dc-dc Converters 36 to 75 Vdc Input, Vdc Output 33 W to 66 W

Part Datasheet
QHW075F1-Q QHW075F1-Q QHW075F1-Q (pdf)
PDF Datasheet Preview
Data Sheet April 2008

QHW050F1-Q, QHW075F1-Q, and QHW100F1-Q Power Modules dc-dc Converters 36 to 75 Vdc Input, Vdc Output 33 W to 66 W

The QHW Series Power Modules use advanced, surfacemount technology and deliver high-quality, efficient, and compact dc-dc conversion.
n Distributed power architectures n Communications equipment n Computer equipment

Options
n Heat sinks available for extended operation n Auto-restart after overtemperature, overvoltage, or
overcurrent shutdown n Choice of short pin lengths n Case ground pin
n Small size mm x mm x mm in. x in. x in.
n High power density
n Extra high efficiency 85% typical
n Low output noise
n Constant frequency
n Industry-standard pinout
n Metal baseplate
n 2:1 input voltage range
n Overvoltage and overcurrent, overtemperature protection
n Negative remote on/off
n Remote sense
n Adjustable output voltage
n ISO* 9001 and ISO 14001 Certified manufacturing facilities
n UL†60950 Recognized, C22.2 No. 60950-00 Certified, and VDE § 0805 EN60950 Licensed
n CE mark meets 73/23/EEC and 93/68/EEC directives**
* ISO is a registered trademark of the International Organization for Standardization.
† UL is a registered trademark of Underwriters Laboratories, Inc. CSA is a registered trademark of Canadian Standards Associa-
tion. § VDE is a trademark of Verband Deutscher Elektrotechniker e.V. ** This product is intended for integration into end-use equipment.

All the required procedures for CE marking of end-use equipment should be followed. The CE mark is placed on selected products.

The QHW050F1-Q, QHW075F1-Q, and QHW100F1-Q Power Modules are dc-dc converters that operate over an input voltage range of 36 Vdc to 75 Vdc and provide a precisely regulated dc output. The outputs are fully isolated from the inputs, allowing versatile polarity configurations and grounding connections. The modules have maximum power ratings from 33 W to 66 W at a typical full-load efficiency of

The sealed modules offer a metal baseplate for excellent thermal performance. Threaded-through holes are provided to allow easy mounting or addition of a heat sink for high-temperature applications. The standard feature set includes remote sensing, output trim, and remote on/off for convenient flexibility in distributed power applications.

QHW050F1-Q, QHW075F1-Q, and QHW100F1-Q Power Modules dc-dc Converters 36 to 75 Vdc Input, Vdc Output 33 W to 66 W

Data Sheet April 2008

Absolute Maximum Ratings

Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are absolute stress ratings only. Functional operation of the device is not implied at these or any other conditions in excess of those given in the operations sections of the data sheet. Exposure to absolute maximum ratings for extended periods can adversely affect device reliability.

Parameter

Unit

Input Voltage Continuous Transient 100 ms

VI, trans

Operating Case Temperature See Thermal Considerations section.

Storage Temperature

Tstg

I/O Isolation Voltage for 1 minute
1500
The temperature at this location should not exceed 100 °C. The output power of the module should not exceed the rated power for the module as listed in the Ordering Information table.

Although the maximum case temperature of the power modules is 100 °C, you can limit this temperature to a lower value for extremely high reliability.

Heat Transfer Without Heat Sinks

Increasing airflow over the module enhances the heat transfer via convection. Figures 25 and 26 show the maximum power that can be dissipated by the module without exceeding the maximum case temperature versus local ambient temperature TA for natural convection through 3 m/s 600 ft./min. .

Note that the natural convection condition was measured at m/s to m/s 10 ft./min. to 20 ft./min. however, systems in which these power modules may be used typically generate natural convection airflow rates of m/s 60 ft./min. due to other heat dissipating components in the system. The use of Figure 25 is shown in the following example.

Example

What is the minimum airflow necessary for a QHW100F1-Q operating at VI = 48 V, an output current of 15 A, transverse orientation, and a maximum ambient temperature of 40 °C?

Solution

Given VI = 48 V IO = 15 A TA = 40 °C

Determine PD Use Figure 29 PD = W

Determine airflow v Use Figure 25 v = m/s 100 ft./min.

Note Top view, pin locations are for reference only. Measurements shown in millimeters and inches .
8-2104 F

Figure Case Temperature Measurement Location

Lineage Power

Data Sheet April 2008

QHW050F1-Q, QHW075F1-Q, and QHW100F1-Q Power Modules dc-dc Converters 36 to 75 Vdc Input, Vdc Output 33 W to 66 W

Thermal Considerations continued Heat Transfer Without Heat Sinks continued

POWER DISSIPATION, PD W
20 m/s 600 ft./min.
m/s 400 ft./min.
m/s 200 ft./min.
m/s 20 ft./min.

NATURAL

CONVECTION
0 10 20 30 40 50 60 70 80 90 100 LOCAL AMBIENT TEMPERATURE, TA °C
8-2321 F .a

Figure Forced Convection Power Derating with No Heat Sink Transverse Orientation

POWER DISSIPATION, PD W
m/s 600 ft./min.
m/s 400 ft./min.
m/s 200 ft./min.
m/s 20 ft./min.

NATURAL

CONVECTION
0 10 20 30 40 50 60 70 80 90 100 LOCAL AMBIENT TEMPERATURE, TA °C
8-2318 F .b

Figure Forced Convection Power Derating with No Heat Sink Longitudinal Orientation

POWER DISSIPATION, PD W

VI = 75 V

VI = 48 V
Ordering Information

Please contact your Lineage Power Account Manager or Field Application Engineer for pricing and availability.

Table Device Codes

Input Voltage 48 Vdc 48 Vdc 48 Vdc

Output Voltage Vdc

Output Power 33 W 66 W

Output Current
10 A 15 A 20 A

Remote On/Off Logic

Negative

Device Code QHW050F1-Q QHW075F1-Q QHW100F1-Q

Comcode
108741596 108741612 108741570

Optional features can be ordered using the suffixes shown in Table To order more than one option, list device codes suffixes in numerically descending order. For example, the device code for a QHW100F1-Q module with the following option is shown below:

Auto-restart after overtemperature, overvoltage, or overcurrent shutdown

QHW100F41-Q

Table Device Options

Option

Short pins mm ± mm in. in.

Case ground pin Short pins mm ± mm
in. ± in. Auto-restart after overtemperature, over-
voltage, or overcurrent shutdown

Device Code Suffix 8

Lineage Power

Data Sheet April 2008

QHW050F1-Q, QHW075F1-Q, and QHW100F1-Q Power Modules dc-dc Converters 36 to 75 Vdc Input, Vdc Output 33 W to 66 W
Ordering Information continued

Table Device Accessories Accessory
1/4 in. transverse kit heat sink, thermal pad, and screws 1/4 in. longitudinal kit heat sink, thermal pad, and screws 1/2 in. transverse kit heat sink, thermal pad, and screws 1/2 in. longitudinal kit heat sink, thermal pad, and screws
1 in. transverse kit heat sink, thermal pad, and screws 1 in. longitudinal kit heat sink, thermal pad, and screws

Dimensions are in millimeters and inches .

Comcode
848060992 848061008 848061016 848061024 848061032 848061040
1/4 IN.
± ±
1/2 IN.
1 IN.
± ±

Figure Longitudinal Heat Sink
8-2473 F
± ±
± ±
1/4 IN. 1/2 IN. 1 IN.

Figure Transverse Heat Sink
8-2472 F

Lineage Power

QHW050F1-Q, QHW075F1-Q, and QHW100F1-Q Power Modules dc-dc Converters 36 to 75 Vdc Input, Vdc Output 33 W to 66 W

Data Sheet April 2008

A sia-Pacific Head qu art ers T el +65 6 41 6 4283

World W ide Headq u arters Lin eag e Po wer Co rp oratio n 30 00 Sk yline D riv e, Mesquite, T X 75149, U SA +1-800-526-7819 Outs id e U .S.A +1- 97 2-2 84 -2626 ag ep ower.co m e-m ail tech sup lin ea gep ower.co m

Eu ro pe, M id dle-East an d Afric a He ad qu arters Tel +49 8 9 6089 286

Ind ia Head qu arters Tel +91 8 0 28411633

Lineage Power reserves the right to make changes to the produc t s or information contained herein without notice. No liability is ass umed as a res ult of their use or applic ation. No rights under any patent acc ompany the sale of any s uc h pr oduct s or information.
2008 Lineage Power Corpor ation, Mesquite, Texas All International Rights Res er ved.

April 2008 FDS01-087EPS Replaces FDS01-086EPS
More datasheets: IXFH28N60P3 | IXFQ28N60P3 | GHDR-16V-S | BM32B-GHDS-G-TF(LF)(SN) | GHDR-32V-S | BM16B-GHDS-G-TF(LF)(SN) | SKB06N60HSATMA1 | CNFMRA | TLE4279GMNTMA1 | TLE4279GNTMA1


Notice: we do not provide any warranties that information, datasheets, application notes, circuit diagrams, or software stored on this website are up-to-date or error free. The archived QHW075F1-Q Datasheet file may be downloaded here without warranties.

Datasheet ID: QHW075F1-Q 645724