Data Sheet March 2008

JC050C, JC075C, JC100C Power Modules dc-dc Converters 18 Vdc to 36 Vdc Input, 15 Vdc Output 50 W to 100 W

The JC050C, JC075C, JC100C Power Modules use advanced, surface-mount technology and deliver high-quality, efficient, compact dc-dc conversion.
n Distributed power architectures n Workstations n EDP equipment n Telecommunications n Wireless

Options
n Choice of remote on/off logic configuration n Heat sink available for extended operation
n Small size mm x mm x mm in. x in. x in.
n High power density n High efficiency 88% typical n Low output noise n Constant frequency n Industry-standard pinout n Metal baseplate n 2:1 input voltage range n Overtemperature protection 100 W only n Remote sense n Remote on/off n Adjustable output voltage n Case ground pin n UL* Recognized, CSA† Certified, VDE Licensed
* UL is a registered trademark of Underwriters Laboratories, Inc. † CSA is a registered trademark of Canadian Standards Assn.

The JC050C, JC075C, JC100C Power Modules are dc-dc converters that operate over an input voltage range of 18 Vdc to 36 Vdc and provide a precisely regulated dc output. The outputs are fully isolated from the inputs, allowing versatile polarity configurations and grounding connections. The modules have maximum power ratings from 50 W to 100 W at typical full-load efficiency of

The sealed modules offer metal baseplate for excellent thermal performance. Threaded-through holes are provided to allow easy mounting or addition of a heat sink for high-temperature applications. The standard feature set includes remote sensing, output trim, and remote on/off for convenient flexibility in distributed power applications.

JC050C, JC075C, JC100C Power Modules dc-dc Converters 18 Vdc to 36 Vdc Input, 15 Vdc Output 50 W to 100 W

Data Sheet March 2008

Absolute Maximum Ratings

Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are absolute stress ratings only. Functional operation of the device is not implied at these or any other conditions in excess of those given in the operations sections of the data sheet. Exposure to absolute maximum ratings for extended periods can adversely affect device reliability.

Parameter

Unit

Input Voltage Continuous

I/O Isolation Voltage
1500

Operating Case Temperature See Thermal Considerations section.

Storage Temperature

Tstg

Electrical Specifications

Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature conditions.

Table Input Specifications

Parameter Operating Input Voltage Maximum Input Current

VI = 0 V to 36 V IO = IO, max JC050C See Figure 1 JC075C JC100C See Figure

Inrush Transient Input Reflected-ripple Current, Peak-to-peak
5 Hz to 20 MHz, 12 µH source impedance see Figure Input Ripple Rejection 120 Hz

Unit

II, max

II, max

II, max
mAp-p

Fusing Considerations

CAUTION This power module is not internally fused. An input line fuse must always be used.

This encapsulated power module can be used in a wide variety of applications, ranging from simple stand-alone operation to an integrated part of a sophisticated power architecture. To preserve maximum flexibility, internal fusing is not included however, to achieve maximum safety and system protection, always use an input line fuse. The safety agencies require a normal-blow, dc fuse with a maximum rating of 20 A see Safety Considerations section . Based on the information provided in this data sheet on inrush energy and maximum dc input current, the same type of fuse with a lower rating can be used. Refer to the fuse manufacturer’s data for further information.

Lineage Power

Data Sheet March 2008

JC050C, JC075C, JC100C Power Modules dc-dc Converters 18 Vdc to 36 Vdc Input, 15 Vdc Output 50 W to 100 W
The temperature at this location should not exceed 100 °C. The output power of the module should not exceed the rated power for the module as listed in the Ordering Information table.

Lineage Power

Data Sheet March 2008

JC050C, JC075C, JC100C Power Modules dc-dc Converters 18 Vdc to 36 Vdc Input, 15 Vdc Output 50 W to 100 W

Thermal Considerations continued

Introduction continued

Although the maximum case temperature of the power modules is 100 °C, you can limit this temperature to a lower value for extremely high reliability.

For additional information on these modules, refer to the Thermal Management JC-, JFC-, JW-, and JFW-Series 50 W to 150 W Board-Mounted Power Modules Technical Note TN97-008EPS .

Heat Transfer Without Heat Sinks

Increasing airflow over the module enhances the heat transfer via convection. Figure 21 shows the maximum power that can be dissipated by the module without exceeding the maximum case temperature versus local ambient temperature TA for natural convection through 4 m/s 800 ft./min. .

Note that the natural convection condition was measured at m/s to m/s 10 ft./min. to 20 ft./min. however, systems in which these power modules may be used typically generate natural convection airflow rates of m/s 60 ft./min. due to other heat dissipating components in the system. The use of Figure 21 is shown in the following example.

Example

What is the minimum airflow necessary for a JC100C operating at nominal line, an output current of 6 A, and a maximum ambient temperature of 40 °C?

Solution

Given VI = 28 V IO = 6 A TA = 40 °C

Determine PD Use Figure

PD = W

Determine airflow v Use Figure
v = m/s 300 ft./min.

POWER DISSIPATION, PD W
m/s 800 ft./min.
m/s 700 ft./min.
m/s 600 ft./min.
m/s 500 ft./min.
m/s 400 ft./min.
m/s 300 ft./min.
m/s 200 ft./min. m/s 100 ft./min.
m/s NAT. CONV.
20 ft./min.
0 10 20 30 40 50 60 70 80 90 100

LOCAL AMBIENT TEMPERATURE, TA
8-1150 C .a

Figure Forced Convection Power Derating with No Heat Sink Either Orientation

POWER DISSIPATION, PD W

VI = 18 V

VI = 28 V

VI = 36 V

OUTPUT CURRENT, IO A

Figure JC050C Power Dissipation vs. Output Current
8-1583 C

Lineage Power
Ordering Information

Input Voltage
28 V 28 V 28 V 28 V 28 V 28 V

Output Voltage V

Output Power 50 W 75 W 100 W 50 W 75 W 100 W

Remote On/ Off Logic negative positive

Device Code JC050C1 JC075C1 JC100C1 JC050C JC075C JC100C

Comcode
107314676 TBD
107314692 107309874

TBD 107309965

Lineage Power

JC050C, JC075C, JC100C Power Modules dc-dc Converters 18 Vdc to 36 Vdc Input, 15 Vdc Output 50 W to 100 W

Data Sheet March 2008

Asia-Pacific Headquart ers Tel +65 6 41 6 4283

World Wide Headquarters Lineage Power Corporation 30 00 Skyline Drive, Mesquite, TX 75149, USA +1-800-526-7819 Outsid e U.S.A +1- 97 2-2 84 -2626 agepower.com e-m ail gepower.com

Europe, Middle-East and Afric a He adquarters Tel +49 8 9 6089 286

India Headquarters Tel +91 8 0 28411633

Lineage Power reserves the right to make changes to the produc t s or information contained herein without notice. No liability is ass umed as a res ult of their use or application. No rights under any patent accompany the sale of any such pr oduct s or information.
2008 Lineage Power Corpor ation, Mesquite, Texas All International Rights Reser ved.

March 2008 DS97-552EPS
More datasheets: 76650-0042 | RAPID-NIEK V0004 | 0201BN180J500NGT | DCME27C2SN | TRX10GDL0610C3 | MIKROE-2706 | 62471-001LF | 62471-001 | MKJ1A6W6-7PB | JC050C1


Notice: we do not provide any warranties that information, datasheets, application notes, circuit diagrams, or software stored on this website are up-to-date or error free. The archived JC100C1 Datasheet file may be downloaded here without warranties.

Datasheet ID: JC100C1 645676