ECT300KIT

ECT300KIT Datasheet


ECT 300 Perpetuum Kit Ultra Low Voltage DC/DC Converter for Thermal Energy Harvesting

Part Datasheet
ECT300KIT ECT300KIT ECT300KIT (pdf)
PDF Datasheet Preview
USER MANUAL V1.0

ECT 300 Perpetuum Kit Ultra Low Voltage DC/DC Converter for Thermal Energy Harvesting

Covered by at least following patents W098/36395 | DE 10025561 | DE 10062028 | DE 10150128 DE 10155125 | DE 10063305 | DE 10301678 | DE29712270.3 W O00/043802 | DE | EP 1389358 | US 7,005,778 B2 EP 1550202 | US 7,019,241 B2 | DE | DE | DE 10256940 | DE 10315765 | DE 10315765

Further patents pending:

EnOcean GmbH Kolpingring 18a 82041 Oberhaching Germany

Phone 34 689-0 Fax 34 689-50

Subject to modification EDK 300 User Manual November 6, 2009 5:03 PM Page 1/8

USER MANUAL

ECT 300 PERPETUUM KIT

Major Changes

Initial version

Updated MK

Published by EnOcean GmbH, Kolpingring 18a, 82041 Oberhaching, Germany phone +49 89 6734 6890

EnOcean GmbH, All Rights Reserved

Important notes!

This information describes the type of component and shall not be considered as assured characteristics. No responsibility is assumed for possible omissions or inaccuracies. Circuitry and specifications are subject to change without notice. For the latest product specifications, refer to the EnOcean website:

As far as patents or other rights of third parties are concerned, liability is only assumed for modules, not for the described applications, processes and circuits.

EnOcean does not assume responsibility for use of modules described and limits its liability to the replacement of modules determined to be defective due to workmanship. Devices or systems containing RF components must meet the essential requirements of the local legal authorities.

The modules must not be used in any relation with equipment that supports, directly or indirectly, human health or life or with applications that can result in danger for people, animals or real value.

Components of the modules are considered and should be disposed of as hazardous waste. Local government regulations are to be observed. Packing Please use the recycling operators known to you. By agreement we will take packing material back if it is sorted. You must bear the costs of transport. For packing material that is returned to us unsorted or that we are not obliged to accept, we shall have to invoice you for any costs incurred.

This evaluation kit and its components are intended for use for evaluation, demonstration or engineering development purposes only. It is not considered to be a finished end product fit for consumer use. Persons handling this developer kit must have electronics expertise and observe good engineering practice standards. As such, the goods being provided are not intended to be complete in terms of required design, marketing, and/or manufacturing related protective considerations, including product safety and environmental measures typically found in end products that incorporate such electronic components or circuit board. EnOcean does not reliable consequences for any HW or SW changes/modifications of the developer board done by the developer.

Observe precautions! Electrostatic sensitive devices!
2009 EnOcean |

EDK300 / EDK300C User Manual | Page 2/8

USER MANUAL

ECT 300 PERPETUUM KIT

TABLE OF CONTENT
Content and ordering information

Technical Data

Usage with EnOcean’s EDK 300 C
2009 EnOcean |

EDK300 / EDK300C User Manual | Page 3/8

USER MANUAL ECT 300 PERPETUUM KIT
1 General Description

Basic Functionality

ECT 300 Perpetuum Kit is intended to evaluate EnOcean’s latest thermal energy harvester solution. ECT 300 is able to power wireless sensor nodes from only a few Kelvin temperature differentials.

ECT 300 Perpetuum Kit is designed as accessory for EnOcean’s self-powered sensor developer kit EDK In combination with this kit a complete thermal powered radio sensor application can be evaluated and programmed.

Typical application:

A typical thermo-driven sensor consists of a sensor element e.g. temperature sensor , a small Peltier element, a heat sink, the new DC/DC converter and a radio module e.g. STM300 . Powered by the temperature differential STM 300 will wake up on a regular basis, e.g. every 10s, acquire sensor values and transmit them via a radio signal over a distance of up to 300m. Typical application areas are home and building automation, automated meter reading, and condition monitoring.

Heat sink Peltier

ECT 300 DC/DC

Sensor + EnOcean

Radio Modul
2 Content and ordering information
1x ECT 300 modul 1x Peltier element with heat sink
1x Peltier element w/o heat sink 1x Thermal compound

Ultra Low Voltage DC/DC Converter Engineering Sample TEC2L-15-15-5.6/73CS combined with SK 426 Fischer Elektronik TEC2L-15-15-5.6/73CS EURECA WLP 004 Fischer Elektronik

Type ECT 300 Perpetuum Kit
Ordering Code S3004-P300

Frequency -
2009 EnOcean |

EDK300 / EDK300C User Manual | Page 4/8

USER MANUAL ECT 300 PERPETUUM KIT
3 Technical Data

ECT 300 DC/DC converter module Physical dimensions Typical supply voltage VIN Max. supply voltage VIN Typical source impedance Typical output voltage VOUT Average efficiency

ECT 300 Dimensions and pin out
20x12x5mm 0.02V 0.50V
1.0V < 2Ohm
3.4V ~30%
987654321
12 mm
8 x mm 20 mm

Pin Name

VIN1

Voltage input External generator connected to this pin

Not connected

Not connected

VIN2

Voltage input External generator connected to this pin

VOutAC AC output for internal use only

Not connected

VOUT

Output voltage of the power converter module

Not connected

GND Ground
2009 EnOcean |

EDK300 / EDK300C User Manual | Page 5/8

USER MANUAL ECT 300 PERPETUUM KIT

Following diagram shows a typical ECT 300 performance in combination with Peltier element TEC2L-15-15-5.6 and heat sink SK Performance will be affected by variance of components and environment air flow etc. .

Pout / uW
1400 1200 1000
800 600 400 200

ECT100perpetuum Stepcode BA
inferior heat sink
de lta T / K

Peltier Element

Type Temperature coefficient Internal resistance Thermal conductivity

Heat Sink

Type Thermal resistance
More datasheets: ATA6660-TAP | ATA6660-TAQ | ATA6660-TAQY 19 | ATA6660-TAPY 19 | ATA6660-TAQY | AK3220X-1.8 | EA8938 | ACT8938 | 0402ESDA-MLPT | 0402ESDB-MLP1


Notice: we do not provide any warranties that information, datasheets, application notes, circuit diagrams, or software stored on this website are up-to-date or error free. The archived ECT300KIT Datasheet file may be downloaded here without warranties.