4184N/17X

4184N/17X Datasheet


Part Datasheet
4184N/17X 4184N/17X 4184N/17X (pdf)
PDF Datasheet Preview
product specification 9694300322

Customer specification Avnet Europe Version Created technical project manager Kammerer, Andreas, 570

INDEX
1 General 2 Mechanics 2
2 CONNECTIONS 3 Operating Data 4 OPERATING DATA - ELECTRICAL INTERFACE - INPUT 4 ELECTRICAL OPERATING DATA 4 OPERATING DATA - ELECTRICAL INTERFACE -OUTPUT 4 ELECTRICAL FEATURES 5 AERODYNAMIC 6 SOUND DATA 6 4 Environment 6 CLIMATIC REQUIREMENTS* 7 5 Safety 7 ELECTRICAL SAFETY 7

Special features according to QMH and company standard have the following definitions "A" Product features or process parameters which influence the safety of a product or the compliance of legal requirements. Must not necessary verified and documented Standards and legal requirements must be considered. "FK" Product features or process parameters which influence the fit and function of a product or which have to be controlled or documented for some other reasons e.g. Customer requirements .
page 1 of 7
product specification 9694300322

General

Fan type Rotational direction looking at rotor Airflow direction Bearing system Lubrication Mounting position Tolerance
clockwise

Air intake over struts

Ball bearing
see sectional drawing of the bearing

Mechanics

General

Width Height Depth Diameter Weight Housing material Impeller material Max. torque when mounted across both mounting flanges Screw size
119,0 mm 119,0 mm 38,0 mm 0,0 mm 0,390 kg Metal Plastic wire outlet corner 170 Ncm remaining corners 300 Ncm ISO 4762 - M3 degreased, without an additional brace and without washer
page 2 of 7

Connections

Electrical connection Length of lead wire Tolerance

Length of tube

Tolerance

Wire gauge AWG Insulation diameter Plug Contact
product specification 9694300322

Plug 310 mm
+- 10,0 mm
22 1,70 mm see drawing see drawing

Wire 3

Colour white

Operation Alarm

The auxiliary shown on the schematic diagram which are required for the intended use are not part of our delivery.
page 3 of 7
product specification 9694300322

Operating Data

Operating Data - Electrical Interface - Input

Control input

None

Electrical Operating Data

Measurement conditions:

Normal air density = 1,2 kg/m3 Temperature 23°C +/- 3°C Motor axis horizontal;warm-up time before measuring 5 minutes unless otherwise specified .In the intake and outlet area there may not be any solid obstruction within 0,5 m.
More datasheets: XEB09-BISA | XEB09-BCS | XEB09-C | 333-2SUGC/S400-A5 | 90018T | 74ACTQ841SPC | 74ACTQ841SCX | 74ACTQ841SC | FJNS4212RTA | FJNS4212RBU


Notice: we do not provide any warranties that information, datasheets, application notes, circuit diagrams, or software stored on this website are up-to-date or error free. The archived 4184N/17X Datasheet file may be downloaded here without warranties.

Datasheet ID: 4184N/17X 510474