NLP65 Medical Series
Part | Datasheet |
---|---|
![]() |
NLP65-9912 (pdf) |
Related Parts | Information |
---|---|
![]() |
NLP65-9908 |
![]() |
NLP65-9929 |
![]() |
NLP65-9924 |
![]() |
NLP65-9920 |
![]() |
NLP65-9915 |
PDF Datasheet Preview |
---|
NLP65 Medical Series Single, dual and triple output LOW POWER AC/DC POWER SUPPLIES 65W AC/DC Universal Input Switch Mode Power Supplies • 85VAC to 264VAC universal input range • Harmonic current correction as standard • Maximum component height inches • UL, CSA and VDE safety approvals • Overvoltage and short circuit protection • 5 x 3 x inch x 32mm footprint The NLP65 Medical series is a 65W universal input AC/DC power supply with input harmonic current correction as standard. This compact design, packed in a 5 x 3 inch card with a maximum component height of inches, is ideal for use in a variety of medical, laboratory and dental applications such as centrifuges, incubators and infusion pumps. The NLP65 Medical series comprises of eight models in single, dual and triple output configurations. Providing 65 Watts of continuous output power with free air convection, the NLP65 Medical series will deliver 75 Watts output power with 20CFM of air. The series, with full medical safety approval to EN60601 and UL2601, is CE marked, greatly accelerating design-in time and reducing system compliance costs. All specifications are typical at nominal input, full load at 25°C unless otherwise stated 2 YEAR WARRANTY SPECIFICATIONS OUTPUT SPECIFICATIONS Output power Natural convection Total regulation Rise time At turn-on Transient response Main output 25% step at 0.1A/µs Temperature coefficient Overvoltage protection Main outputs Short circuit protection Cyclic operation INPUT SPECIFICATIONS Input voltage range See Note 2 Universal input Input frequency range Input surge current cold start 120VAC 230VAC Safety ground leakage current 264VAC, 60Hz Input current 120VAC 230VAC Input fuse 65W max. See table 1.0s, max. max. dev., 1ms recovery to ±0.02%/°C 125%, ±10% 85 to 264VAC 47Hz to 63Hz 17A max. 32A max. 95µA 1.05A rms 0.51A rms 250VAC F 3.15A EMC CHARACTERISTICS Conducted emissions Radiated emissions ESD air ESD contact Surge Fast transients Radiated immunity Conducted immunity EN55022, FCC part 15 EN55022, FCC part 15 EN61000-4-2, level 3 EN61000-4-2, level 4 EN61000-4-5, level 3 EN61000-4-4, level 3 EN61000-4-3, level 3 EN61000-4-6, level 3 Level A Level A Perf. criteria 1 Perf. criteria 1 Perf. criteria 1 Perf. criteria 1 Perf. criteria 2 Perf. criteria 2 GENERAL SPECIFICATIONS Hold-up time |
More datasheets: PWM0819 WH005 | 3312V | FDV304P_NB8U003 | FDV304P | FDV304P-D87Z | NLP65-9908 | NLP65-9929 | NLP65-9924 | NLP65-9920 | NLP65-9915 |
Notice: we do not provide any warranties that information, datasheets, application notes, circuit diagrams, or software stored on this website are up-to-date or error free. The archived NLP65-9912 Datasheet file may be downloaded here without warranties.