NLP65-9908

NLP65-9908 Datasheet


NLP65 Medical Series

Part Datasheet
NLP65-9908 NLP65-9908 NLP65-9908 (pdf)
Related Parts Information
NLP65-9929 NLP65-9929 NLP65-9929
NLP65-9924 NLP65-9924 NLP65-9924
NLP65-9920 NLP65-9920 NLP65-9920
NLP65-9915 NLP65-9915 NLP65-9915
NLP65-9912 NLP65-9912 NLP65-9912
PDF Datasheet Preview
NLP65 Medical Series

Single, dual and triple output

LOW POWER AC/DC POWER SUPPLIES 65W AC/DC Universal Input Switch Mode Power Supplies
• 85VAC to 264VAC universal input range
• Harmonic current correction as standard
• Maximum component height inches
• UL, CSA and VDE safety approvals
• Overvoltage and short circuit protection
• 5 x 3 x inch x 32mm footprint

The NLP65 Medical series is a 65W universal input AC/DC power supply with input harmonic current correction as standard. This compact design, packed in a 5 x 3 inch card with a maximum component height of inches, is ideal for use in a variety of medical, laboratory and dental applications such as centrifuges, incubators and infusion pumps. The NLP65 Medical series comprises of eight models in single, dual and triple output configurations. Providing 65 Watts of continuous output power with free air convection, the NLP65 Medical series will deliver 75 Watts output power with 20CFM of air. The series, with full medical safety approval to EN60601 and UL2601, is CE marked, greatly accelerating design-in time and reducing system compliance costs.

All specifications are typical at nominal input, full load at 25°C unless otherwise stated
2 YEAR WARRANTY

SPECIFICATIONS

OUTPUT SPECIFICATIONS

Output power

Natural convection

Total regulation

Rise time

At turn-on

Transient response

Main output 25% step at 0.1A/µs

Temperature coefficient

Overvoltage protection Main outputs

Short circuit protection Cyclic operation

INPUT SPECIFICATIONS

Input voltage range See Note 2

Universal input

Input frequency range

Input surge current cold start
120VAC 230VAC

Safety ground leakage current
264VAC, 60Hz

Input current
120VAC 230VAC

Input fuse
65W max. See table 1.0s, max. max. dev., 1ms recovery
to ±0.02%/°C 125%, ±10%
85 to 264VAC
47Hz to 63Hz 17A max. 32A max. 95µA
1.05A rms 0.51A rms 250VAC F 3.15A

EMC CHARACTERISTICS

Conducted emissions Radiated emissions ESD air ESD contact Surge Fast transients Radiated immunity Conducted immunity

EN55022, FCC part 15 EN55022, FCC part 15 EN61000-4-2, level 3 EN61000-4-2, level 4 EN61000-4-5, level 3 EN61000-4-4, level 3 EN61000-4-3, level 3 EN61000-4-6, level 3

Level A Level A Perf. criteria 1 Perf. criteria 1 Perf. criteria 1 Perf. criteria 1 Perf. criteria 2 Perf. criteria 2

GENERAL SPECIFICATIONS

Hold-up time