AS13985F28_EK_ST

AS13985F28_EK_ST Datasheet


AS13985 - Evaluation Board

Part Datasheet
AS13985F28_EK_ST AS13985F28_EK_ST AS13985F28_EK_ST (pdf)
Related Parts Information
AS13985F30_EK_ST AS13985F30_EK_ST AS13985F30_EK_ST
AS13985F29_EK_ST AS13985F29_EK_ST AS13985F29_EK_ST
AS13985F27_EK_ST AS13985F27_EK_ST AS13985F27_EK_ST
AS13985F26_EK_ST AS13985F26_EK_ST AS13985F26_EK_ST
AS13985F18_EK_ST AS13985F18_EK_ST AS13985F18_EK_ST
AS13985F12_EK_ST AS13985F12_EK_ST AS13985F12_EK_ST
AS13985F33_EK_ST AS13985F33_EK_ST AS13985F33_EK_ST
PDF Datasheet Preview
AS13985 - Evaluation Board

Application Note

AS13985

Evaluation Board Application Note

AS13985 - Evaluation Board

Application Note

Board Description

Figure 1 Board Description - Connector

Figure 2 Board Description Measurement Points

Connector Description

Label

Jumper

Vin GND

Power Supply Connectors for Vin and Ground.

Vin / GND

EN Enable Jumper

Vout

Power Output Connector

Out, GND

Power Output and Ground Connector

Measurement Points

Info
+2.5V to +5.5V
1/ON = The AS13985 is on.
0/OFF = The AS13985 is off and the current into Vin is typ . Regulated Output Voltage Additional Connectors to apply a load

Label

F G H I J

Jumper

EN Vin GND Vout U1GND

Enable Pin Connector1 Power Supply Connectors for Vin and Ground.

Power Output Connector IQ Quiescent Current Connector2

Info

Measurement Points

Operational sequence

If not present get the datasheet for the AS13985 from Drive the IC on the evaluation board only with the recommended settings and values as described in the datasheet.

Connect a +2.5V to +5.5V power supply Vin “A” and GND “B” .

Perform measurements at the measurement points.

Have fun using the Evaluation Board. If there are questions do not hesitate to contact us. See contact information at the end of the application note.
1 If the EN measurement point F is used as a connector, be sure that the EN jumper C is completely removed. Otherwise the supply source could
be damage through a short circuit. 2 For normal operation jumper J has to be always set. For the measurement of the quiescent current remove the jumper and connect an analyzer
here.
More datasheets: 335104-13-0300 | 335104-13-0200 | 335104-13-0100 | 335104-13-0050 | 335104-13-0250 | FDU8878 | FDD8878 | 624 | AS13985F30_EK_ST | AS13985F29_EK_ST


Notice: we do not provide any warranties that information, datasheets, application notes, circuit diagrams, or software stored on this website are up-to-date or error free. The archived AS13985F28_EK_ST Datasheet file may be downloaded here without warranties.

Datasheet ID: AS13985F28_EK_ST 519629