90MT.KB 110MT.KB Units
Part | Datasheet |
---|---|
![]() |
110MT160KB (pdf) |
Related Parts | Information |
---|---|
![]() |
90MT160KB |
![]() |
90MT120KB |
![]() |
90MT80KB |
![]() |
90MT100KB |
![]() |
110MT80KB |
![]() |
110MT100KB |
![]() |
110MT120KB |
![]() |
110MT140KB |
![]() |
90MT140KB |
PDF Datasheet Preview |
---|
THREE PHASE BRIDGE MT..KB SERIES Power Modules Package fully compatible with the industry standard INT-Apak power modules series High thermal conductivity package, electrically insulated case Outstanding number of power encapsulated components Excellent power volume ratio, outline for easy connections to power transistor and IGBT modules 4000 VRMS isolating voltage UL E78996 approved A range of extremely compact, encapsulated three phase bridge rectifiers offering efficient and reliable operation. They are intended for use in general purpose and heavy duty applications. Major Ratings and Characteristics Parameters 90MT.KB 110MT.KB Units IFSM VRRM TSTG TJ TC 50Hz 60Hz 50Hz 60Hz range 90 120 110 150 90 61 90 57 1000 3000 4500 2700 4100 30000 45000 800 to 1600 - 40 to 150 - 40 to 150 A °C A A2s V °C °C 90 A 110 A 90-110MT..KB Series ELECTRICAL SPECIFICATIONS Voltage Ratings Voltage Type number Code 1000 90-110MT..KB 1200 1400 1600 V 900 1100 1300 1500 1700 IRRM max. TJ max. Forward Conduction Parameter 90MT.KB 110MT.KB Units Conditions Ordering Information Table Device Code 11 0 MT 160 K B 1 2 34 1 - Current rating code 9 = 90 A Avg 11 = 110 A Avg 2 - Three phase diodes bridge 3 - Essential part number 4 - Voltage code x 10 = VRRM See Voltage Ratings Table 5 - Generation II Outline Table without optional barriers All dimensions in millimeters inches NOTE To order the Optional Hardware see Bulletin I27900 90-110MT..KB Series Outline Table with optional barriers All dimensions in millimeters inches Maximum Allowable Case Temperature °C Instantaneous Forward Current A 150 90MT..KB Series 120° Rect 75 100 125 Total Output Current A Fig. 1 - Current Ratings Characteristics 1000 TJ = 25°C TJ = 150°C 10 90MT..KB Series Per Junction Instantaneous Forward Voltage V Fig. 2 - Forward Voltage Drop Characteristics Maximum Total Power Loss W 90-110MT..KB Series - Delta R = K/W R thSA 90MT..KB Series 350 TJ = 150°C 120° Rect K/W K/W 1 K/W 0 20 40 60 80 100 1020 25 50 75 100 125 150 Total Output Current A Maximum Allowable Ambient Temperature °C Fig. 3 - Total Power Loss Characteristics Peak Half Sine Wave Forward Current A 700 At Any Rated Load Condition And With 650 Rated V RRM Applied Following Surge. Initial TJ = 150°C 60 Hz s 50 Hz s 250 90MT..KB Series 200 1 Number Of Equal Amplitude Half Cycle Current Pulses N |
More datasheets: LFL026108 | KU80960CA16 | 90MT160KB | 90MT120KB | 90MT80KB | 90MT100KB | 110MT80KB | 110MT100KB | 110MT120KB | 110MT140KB |
Notice: we do not provide any warranties that information, datasheets, application notes, circuit diagrams, or software stored on this website are up-to-date or error free. The archived 110MT160KB Datasheet file may be downloaded here without warranties.