110MT140KB

110MT140KB Datasheet


90MT.KB 110MT.KB Units

Part Datasheet
110MT140KB 110MT140KB 110MT140KB (pdf)
Related Parts Information
90MT160KB 90MT160KB 90MT160KB
90MT120KB 90MT120KB 90MT120KB
90MT80KB 90MT80KB 90MT80KB
90MT100KB 90MT100KB 90MT100KB
110MT80KB 110MT80KB 110MT80KB
110MT100KB 110MT100KB 110MT100KB
110MT120KB 110MT120KB 110MT120KB
110MT160KB 110MT160KB 110MT160KB
90MT140KB 90MT140KB 90MT140KB
PDF Datasheet Preview
THREE PHASE BRIDGE

MT..KB SERIES

Power Modules

Package fully compatible with the industry standard INT-Apak power modules series High thermal conductivity package, electrically insulated case Outstanding number of power encapsulated components Excellent power volume ratio, outline for easy connections to power transistor and IGBT modules 4000 VRMS isolating voltage UL E78996 approved

A range of extremely compact, encapsulated three phase bridge rectifiers offering efficient and reliable operation. They are intended for use in general purpose and heavy duty applications.

Major Ratings and Characteristics

Parameters
90MT.KB 110MT.KB Units

IFSM

VRRM TSTG TJ

TC 50Hz 60Hz 50Hz 60Hz
range
90 120 110 150
90 61
90 57
1000
3000
4500
2700
4100
30000
45000
800 to 1600
- 40 to 150
- 40 to 150

A °C A A2s V °C °C
90 A 110 A
90-110MT..KB Series

ELECTRICAL SPECIFICATIONS

Voltage Ratings

Voltage Type number Code
1000
90-110MT..KB
1200 1400 1600

V 900
1100
1300 1500 1700

IRRM max. TJ max.

Forward Conduction

Parameter
90MT.KB 110MT.KB Units Conditions
Ordering Information Table

Device Code
11 0 MT 160 K B
1 2 34
1 - Current rating code 9 = 90 A Avg 11 = 110 A Avg
2 - Three phase diodes bridge 3 - Essential part number 4 - Voltage code x 10 = VRRM See Voltage Ratings Table 5 - Generation II

Outline Table without optional barriers

All dimensions in millimeters inches

NOTE To order the Optional Hardware see Bulletin I27900
90-110MT..KB Series

Outline Table with optional barriers

All dimensions in millimeters inches

Maximum Allowable Case Temperature °C Instantaneous Forward Current A
150 90MT..KB Series
120° Rect
75 100 125

Total Output Current A

Fig. 1 - Current Ratings Characteristics
1000

TJ = 25°C TJ = 150°C 10
90MT..KB Series Per Junction

Instantaneous Forward Voltage V

Fig. 2 - Forward Voltage Drop Characteristics

Maximum Total Power Loss W
90-110MT..KB Series
- Delta R = K/W R thSA
90MT..KB Series 350 TJ = 150°C
120° Rect

K/W K/W 1 K/W
0 20 40 60 80 100 1020 25 50 75 100 125 150

Total Output Current A

Maximum Allowable Ambient Temperature °C

Fig. 3 - Total Power Loss Characteristics

Peak Half Sine Wave Forward Current A
700 At Any Rated Load Condition And With
650 Rated V RRM Applied Following Surge.

Initial TJ = 150°C 60 Hz s
50 Hz s
250 90MT..KB Series
200 1

Number Of Equal Amplitude Half Cycle Current Pulses N
More datasheets: 1727040044 | LFL026108 | KU80960CA16 | 90MT160KB | 90MT120KB | 90MT80KB | 90MT100KB | 110MT80KB | 110MT100KB | 110MT120KB


Notice: we do not provide any warranties that information, datasheets, application notes, circuit diagrams, or software stored on this website are up-to-date or error free. The archived 110MT140KB Datasheet file may be downloaded here without warranties.

Datasheet ID: 110MT140KB 638963