NMX-350 Power Factor Corrected Multiple Output, Forced Current Sharing
Part | Datasheet |
---|---|
![]() |
NMX-354-1224G (pdf) |
Related Parts | Information |
---|---|
![]() |
NMX-354-1205 |
![]() |
NMX-354-1205G |
![]() |
NMX-354-1205FG |
![]() |
NMX-354-1212FG |
![]() |
NMX-354-1212EG |
![]() |
NMX-354-1212VG |
![]() |
NMX-354-1212G |
![]() |
NMX-354-1224VG |
![]() |
NMX-354-1224EVG |
![]() |
NMX-354-1205VG |
PDF Datasheet Preview |
---|
NMX-350 Power Factor Corrected Multiple Output, Forced Current Sharing Option V FEATURES: • Forced current sharing for N +1 redundancy • Universal ac input • typical power factor • Dual converter design eliminates interaction between logic and auxiliary outputs • Low ripple and noise on all outputs • Dc power good and ac power fail signals • True remote inhibit • Monotonic turn-on and turn-off Option E SPECIFICATIONS: INPUT Ac Input 90-264 Vac continuous range, 47 to 63 Hz. Internally fused for 7 A. Power Factor typical at full load. Meets EN61000-3-2 Class A. Inrush Cold start ac current is less than 30 A at 115 Vac and 60 A at 230 Vac. Limited by thermistor. Brownout Protection Holds regulation to 85 Vac. Holdup Time 20 ms minimum after removal of power at full load. Efficiency 75% typical. Ac Power Fail Provides TTL “0” 5 ms before output voltage goes out of regulation band upon loss of ac power. OUTPUT Adjustability Outputs #1 and 2 user adjustable ±5% minimum. Output #3 tracks #2 initial accuracy Output #4 user adjustable ±5% minimum, or +5% only if voltage is V. Line & Load Reg Outputs #1, 2, and 4 hold ±1% over ac input range and 0 to 100% load change. Output #3 requires 20% minimum load on outputs #2 and 3 to hold Ripple & Noise Less than 1% p-p or 100 mV, whichever is greater. Remote Sense Output #1 Compensates for 250 mV total line drop. Open sense lead protection. Redundancy External OR-ing diodes and forced current sharing on output #1 provide “N+1” capability. Remote sense +S compensates for additional V diode voltage drop. When the current sharing terminal is connected between units, current sharing remains within 10% of the unit’s full output current rating. Temperature Coefficient Outputs #1, 2, and 4 per degree C. Stability over 8 hours after 30 minutes warm-up. Transient Response Outputs #1, 2, and 4 Output voltage returns to within 1% in less than 500 µs for a 50% load change. Peak transient does not exceed Overload Protection All outputs are protected against overload and short circuit. Automatic recovery upon removal of fault. Overvoltage Protection Outputs #1 and 2 Protects load against power supply induced overvoltage. Trip point is factory set so that output voltage cannot exceed 136% of nominal. Peak Output Current Dual current ratings define continuous and peak currents. The peak current shown can be delivered for a maximum period of 30 seconds. Remote Inhibit Contact closure to the negative sense line or a TTL level “0” turns off dc outputs. Dc Power Good Provides a TTL “1” open collector when output #1 is above V nominal. AC INPUT FUNCTION 115 VAC 230 VAC CONNECTOR TB1- L Line Line 1 Barrier strip TB1- N Neutral Line 2 #6-32 screws TB1- GND Safety Ground Safety Ground Centers DC OUTPUT FUNCTION LOCATION Output #1 Terminal marked +V Terminal marked -V Output #2 J1-1,6 J1-2,7 Output #3 J1-3,8 J1-2,7 Output #4 J1-4,9 J1-5,10 NOTES Main output Rtn common |
More datasheets: TS112N | TS112NTR | NMX-354-1205 | NMX-354-1205G | NMX-354-1205FG | NMX-354-1212FG | NMX-354-1212EG | NMX-354-1212VG | NMX-354-1212G | NMX-354-1224VG |
Notice: we do not provide any warranties that information, datasheets, application notes, circuit diagrams, or software stored on this website are up-to-date or error free. The archived NMX-354-1224G Datasheet file may be downloaded here without warranties.