NMX-350 Power Factor Corrected Multiple Output, Forced Current Sharing

Part Datasheet
NMX-354-1212EG NMX-354-1212EG NMX-354-1212EG (pdf)
Related Parts Information
NMX-354-1205 NMX-354-1205 NMX-354-1205
NMX-354-1205G NMX-354-1205G NMX-354-1205G
NMX-354-1205FG NMX-354-1205FG NMX-354-1205FG
NMX-354-1212FG NMX-354-1212FG NMX-354-1212FG
NMX-354-1212VG NMX-354-1212VG NMX-354-1212VG
NMX-354-1212G NMX-354-1212G NMX-354-1212G
NMX-354-1224VG NMX-354-1224VG NMX-354-1224VG
NMX-354-1224G NMX-354-1224G NMX-354-1224G
NMX-354-1224EVG NMX-354-1224EVG NMX-354-1224EVG
NMX-354-1205VG NMX-354-1205VG NMX-354-1205VG
PDF Datasheet Preview
NMX-350 Power Factor Corrected Multiple Output, Forced Current Sharing

Option V

FEATURES:
• Forced current sharing for N +1 redundancy
• Universal ac input
• typical power factor
• Dual converter design eliminates interaction between
logic and auxiliary outputs
• Low ripple and noise on all outputs
• Dc power good and ac power fail signals
• True remote inhibit
• Monotonic turn-on and turn-off

Option E

SPECIFICATIONS:

INPUT Ac Input 90-264 Vac continuous range, 47 to 63 Hz. Internally fused for 7 A. Power Factor typical at full load. Meets EN61000-3-2 Class A. Inrush Cold start ac current is less than 30 A at 115 Vac and 60 A at 230 Vac. Limited by thermistor. Brownout Protection Holds regulation to 85 Vac. Holdup Time 20 ms minimum after removal of power at full load. Efficiency 75% typical. Ac Power Fail Provides TTL “0” 5 ms before output voltage goes out of regulation band upon loss of ac power. OUTPUT Adjustability Outputs #1 and 2 user adjustable ±5% minimum. Output #3 tracks #2 initial accuracy Output #4 user adjustable ±5% minimum, or +5% only if voltage is V. Line & Load Reg Outputs #1, 2, and 4 hold ±1% over ac input range and 0 to 100% load change. Output #3 requires 20% minimum load on outputs #2 and 3 to hold Ripple & Noise Less than 1% p-p or 100 mV, whichever is greater. Remote Sense Output #1 Compensates for 250 mV total line drop. Open sense lead protection. Redundancy External OR-ing diodes and forced current sharing on output #1 provide “N+1” capability. Remote sense +S compensates for additional V diode voltage drop. When the current sharing terminal is connected between units, current sharing remains within 10% of the unit’s full output current rating. Temperature Coefficient Outputs #1, 2, and 4 per degree C. Stability over 8 hours after 30 minutes warm-up. Transient Response Outputs #1, 2, and 4 Output voltage returns to within 1% in less than 500 µs for a 50% load change. Peak transient does not exceed Overload Protection All outputs are protected against overload and short circuit. Automatic recovery upon removal of fault. Overvoltage Protection Outputs #1 and 2 Protects load against power supply induced overvoltage. Trip point is factory set so that output voltage cannot exceed 136% of nominal. Peak Output Current Dual current ratings define continuous and peak currents. The peak current shown can be delivered for a maximum period of 30 seconds. Remote Inhibit Contact closure to the negative sense line or a TTL level “0” turns off dc outputs. Dc Power Good Provides a TTL “1” open collector when output #1 is above V nominal.

AC INPUT

FUNCTION
115 VAC
230 VAC

CONNECTOR

TB1- L

Line

Line 1

Barrier strip

TB1- N

Neutral

Line 2
#6-32 screws

TB1- GND

Safety Ground

Safety Ground

Centers

DC OUTPUT

FUNCTION

LOCATION

Output #1

Terminal marked +V

Terminal marked -V

Output #2

J1-1,6

J1-2,7

Output #3

J1-3,8

J1-2,7

Output #4

J1-4,9

J1-5,10

NOTES Main output Rtn common