F0494A

F0494A Datasheet


L-15PL012D-C-2 F0491A 12VDC Continuous

Part Datasheet
F0494A F0494A F0494A (pdf)
Related Parts Information
F0492A F0492A F0492A
F0491A F0491A F0491A
F0493A F0493A F0493A
PDF Datasheet Preview
2110 Queensway Searcy, AR 72143 Phone 501-268-6877 Website:

Model L-15 DC Solenoid Tubular, Pull Type

Pontiac Coil - Arkansas is an ISO 9001:2000 Certified Company
*Resistance values are ± 10% at 25°C

Model Code Part No. Voltage Duty Cycle

Power W Resistance Current A

L-15PL012D-C-2 F0491A 12VDC Continuous

L-15PL012D-I-2 F0492A 12VDC Intermittent

L-15PL024D-C-2 F0493A 24VDC Continuous

L-15PL024D-I-2 F0494A 24VDC Intermittent

Definition of Duty Cycles:

Continuous = indefinite activation Intermittent = 1 minute ON and 3 minutes OFF Pulse = 100msec. ON and 900 msec. OFF

Special order options 6 to 48Volts, DC only push-type configuration. Consult factory for other modifications.

Stroke in. Sealed
1-1/4

Cont. Duty force 200 oz. 128 oz. 64 oz.
38 oz.
24 oz.
13 oz.
5 oz.
3 oz.

Int. Duty force
245 oz. 184 oz. 138 oz. 110 oz. 80 oz. 48 oz. 28 oz. 16 oz.

Typical force values when operated at 100% rated voltage at 25°C. Derating required for lower voltage and higher temperature.

Solenoid supplied with 1-1/8" hex panel nut 1-27 UNS 2B thread

Solenoid shown energized, with plunger seated

Insulation Materials UL Construction, Class B 130°C Copper magnet wire insulation rated 155°C class F

Voltage Breakdown Strength 1500 VAC RMS Life Expectancy 10 million operations
More datasheets: BDNF800A | BDNF4004 | Z8F08A28100KIT | Z8F08A28100KITG | KT0007 | 12128 | 8819/10 | AT-41435G | F0492A | F0491A


Notice: we do not provide any warranties that information, datasheets, application notes, circuit diagrams, or software stored on this website are up-to-date or error free. The archived F0494A Datasheet file may be downloaded here without warranties.

Datasheet ID: F0494A 515735