POWR-BLOKS Distribution/Splicer Blocks and Covers SPECIFICATIONS Voltage Rating 600V Amperage Based on NEC Table 310-16, using 75°C copper wire Material Phenolic rated at 150°C and Thermoplastic rated at 125°C LD1400 and LS1300 series only Connector Standard Highly conductive aluminum, tin plated Copper Highly conductive copper, tin plated Flammability Rating 94V-0 Approvals UL Recognized File No. E171395 CSA Certified File No. LR700111 ORDERING INFORMATION POWR-BLOKS power distribution and splicer blocks offer a safe, convenient way of splicing cables, providing a fixed junction tap-off point, or splitting primary power into secondary circuits. Blocks have one or two primary inputs, with up to twelve secondary outputs per pole. The number of poles available ranges from one to four. Distribution Block Example Part No. L D 2570 -3 Splicer Block Example Part No. L S 3126 -2 Littelfuse Distribution Block Series No. of Poles Littelfuse Splicer Block Series No. of Poles Typical applications include heating, air conditioning and refrigeration systems, elevator systems, material handling equipment, control panels, motor controls, switchgear, and anywhere power needs to be distributed to more than one load. CONNECTORS Box lug connectors are designed for use with a single, solid or class B or C stranded conductor. Use of more than one conductor per connector opening or use of extra-flexible, fine stranded conductors, such as welding cable, voids the UL Listing, and may cause overheating. Manufacturers of cable terminations can furnish crimp-on sleeves for fine stranded conductors which permit these conductors to be used with box lugs. AMPERE RATINGS The ampere rating per pole for power distribution blocks is based on the line ampacity of 75° C insulated conductors per NEC Table If 60° C insulated conductors are used, load must not exceed the ampacity of 60° C conductors. Use of conductors rated in excess of 75° C is permitted for example 90° C , however, load must not exceed the ampacity of 75° C conductors. Distribution Block Covers Power Distribution Block Covers provide protection against accidental shorting between poles caused by loose wires, tools or other conductive material. They also protect personnel from accidentally contacting energized connectors. SPECIFICATIONS Material clear plexiglas . FEATURES Two thread-cutting screws are furnished for each cover. Covers are slotted for easy installation. Covers available for all Power Distribution Blocks ...see below. Power Distribution/Splicer Block Cover Selection Guide & Dimensions Littelfuse Part Number LPBC0-2 LPBC0-3 LPBC2-1 LPBC2-2 LPBC2-3 LPBC3-1 LPBC3-2 LPBC3-3 LPBC4-1 LPBC4-2 LPBC4-3 LPBC5-1 LPBC5-2 LPBC5-3 For use with Power Distribution Block No. LX0XXX-2 LX0XXX-3 LX2XXX-1 LX2XXX-2 LX2XXX-3 LX3XXX-1 LX3XXX-2 LX3XXX-3 LX4XXX-1 LX4XXX-2 LX4XXX-3 LX5XXX-1 LX5XXX-2 LX5XXX-3 POWR-BLOKS Distribution/Splicer Blocks and Covers Distribution Block Selection Guide Mat’l Connector Configuration Line Load Amp Rating Number per Pole of Poles Line Wire Range |
More datasheets: PTFA212401F V4 | PTFA212401E V4 | PTFA212401E V4 R250 | PTFA212401F V4 R250 | ETST667 | SPB160N04S2L03DTMA1 | 0LD55523Z | 0LD04013Z | 0LD14003Z | 0LD55863Z |
Notice: we do not provide any warranties that information, datasheets, application notes, circuit diagrams, or software stored on this website are up-to-date or error free. The archived 0LD35553Z Datasheet file may be downloaded here without warranties.