POWR-BLOKS Distribution/Splicer Blocks and Covers

SPECIFICATIONS Voltage Rating 600V Amperage Based on NEC Table 310-16,
using 75°C copper wire Material Phenolic rated at 150°C and Thermoplastic rated
at 125°C LD1400 and LS1300 series only Connector Standard Highly conductive aluminum, tin plated

Copper Highly conductive copper, tin plated Flammability Rating 94V-0 Approvals UL Recognized File No. E171395

CSA Certified File No. LR700111
ORDERING INFORMATION

POWR-BLOKS power distribution and splicer blocks offer a safe, convenient way of splicing cables, providing a fixed junction tap-off point, or splitting primary power into secondary circuits. Blocks have one or two primary inputs, with up to twelve secondary outputs per pole. The number of poles available ranges from one to four.

Distribution Block Example Part No.

L D 2570 -3

Splicer Block Example Part No.

L S 3126 -2

Littelfuse Distribution

Block Series No. of Poles Littelfuse Splicer Block Series No. of Poles

Typical applications include heating, air conditioning and refrigeration systems, elevator systems, material handling equipment, control panels, motor controls, switchgear, and anywhere power needs to be distributed to more than one load.

CONNECTORS

Box lug connectors are designed for use with a single, solid or class B or C stranded conductor. Use of more than one conductor per connector opening or use of extra-flexible, fine stranded conductors, such as welding cable, voids the UL Listing, and may cause overheating. Manufacturers of cable terminations can furnish crimp-on sleeves for fine stranded conductors which permit these conductors to be used with box lugs.

AMPERE RATINGS

The ampere rating per pole for power distribution blocks is based on the line ampacity of 75° C insulated conductors per NEC Table If 60° C insulated conductors are used, load must not exceed the ampacity of 60° C conductors. Use of conductors rated in excess of 75° C is permitted for example 90° C , however, load must not exceed the ampacity of 75° C conductors.

Distribution Block Covers

Power Distribution Block Covers provide protection against accidental shorting between poles caused by loose wires, tools or other conductive material. They also protect personnel from accidentally contacting energized connectors.

SPECIFICATIONS Material clear plexiglas .

FEATURES Two thread-cutting screws are furnished for each cover. Covers are slotted for easy installation. Covers available for all Power Distribution Blocks ...see below.

Power Distribution/Splicer Block Cover Selection Guide & Dimensions

Littelfuse Part

Number

LPBC0-2 LPBC0-3

LPBC2-1 LPBC2-2 LPBC2-3

LPBC3-1 LPBC3-2 LPBC3-3

LPBC4-1 LPBC4-2 LPBC4-3

LPBC5-1 LPBC5-2 LPBC5-3

For use with Power Distribution

Block No.

LX0XXX-2 LX0XXX-3

LX2XXX-1 LX2XXX-2 LX2XXX-3

LX3XXX-1 LX3XXX-2 LX3XXX-3

LX4XXX-1 LX4XXX-2 LX4XXX-3

LX5XXX-1 LX5XXX-2 LX5XXX-3

POWR-BLOKS Distribution/Splicer Blocks and Covers

Distribution Block Selection Guide

Mat’l

Connector Configuration

Line

Load

Amp Rating Number per Pole of Poles

Line

Wire Range
More datasheets: ETST667 | SPB160N04S2L03DTMA1 | 0LD55523Z | 0LD04013Z | 0LD14003Z | 0LD55863Z | 0LD35553Z | 0LD55793Z | 0LD35523Z | 0LD35533Z