TXM-315-LC LOT CTxxxx
Part | Datasheet |
---|---|
![]() |
TXM-418-LC (pdf) |
Related Parts | Information |
---|---|
![]() |
RXM-315-LC-S |
![]() |
RXM-418-LC-S |
![]() |
TXM-315-LC |
![]() |
TXM-433-LC |
PDF Datasheet Preview |
---|
LC Series Transmitter Module Data Guide ! Warning Some customers may want Linx radio frequency “RF” products to control machinery or devices remotely, including machinery or devices that can cause death, bodily injuries, and/or property damage if improperly or inadvertently triggered, particularly in industrial settings or other applications implicating life-safety concerns “Life and Property Safety Situations” . NO OEM LINX REMOTE CONTROL OR FUNCTION MODULE SHOULD EVER BE USED IN LIFE AND PROPERTY SAFETY SITUATIONS. No OEM Linx Remote Control or Function Module should be modified for Life and Property Safety Situations. Such modification cannot provide sufficient safety and will void the product’s regulatory certification and warranty. Customers may use our non-Function Modules, Antenna and Connectors as part of other systems in Life Safety Situations, but only with necessary and industry appropriate redundancies and in compliance with applicable safety standards, including without limitation, ANSI and NFPA standards. It is solely the responsibility of any Linx customer who uses one or more of these products to incorporate appropriate redundancies and safety standards for the Life and Property Safety Situation application. Do not use this or any Linx product to trigger an action directly from the data line or RSSI lines without a protocol or encoder/ decoder to validate the data. Without validation, any signal from another unrelated transmitter in the environment received by the module could inadvertently trigger the action. All RF products are susceptible to RF interference that can prevent communication. RF products without frequency agility or hopping implemented are more subject to interference. This module does have a frequency hopping protocol built in, but the developer should still be aware of the risk of interference. Do not use any Linx product over the limits in this data guide. Excessive voltage or extended operation at the maximum voltage could cause product failure. Exceeding the reflow temperature profile could cause product failure which is not immediately evident. Do not make any physical or electrical modifications to any Linx product. This will void the warranty and regulatory and UL certifications and may cause product failure which is not immediately evident. Table of Contents Description Features Applications Ordering Information Absolute Maximum Ratings Electrical Specifications Typical Performance Graphs Pin Assignments Pin Descriptions Module Description Theory of Operation The Data Input Adjusting the Output Power Transferring Data Power Supply Requirements Typical Applications ESD Concerns Antenna Considerations Helpful Application Notes from Linx Protocol Guidelines Interference Considerations Pad Layout Board Layout Guidelines Microstrip Details Production Guidelines Hand Assembly Automated Assembly General Antenna Rules Common Antenna Styles Regulatory Considerations LC Series Transmitter Module Data Guide The LC Series is ideally suited for volume use in OEM applications such as remote control, security, identification and periodic data transfer. Housed in a compact surface-mount package, the LC in mm TXM-315-LC LOT CTxxxx in mm Series transmitter utilizes a highly-optimized SAW in Max. architecture to achieve an unmatched blend of performance, size, efficiency and cost. When paired with a matching LR Series receiver, a Figure 1 Package Dimensions highly reliable wireless link is formed, capable of transferring serial data at distances of up to 3,000 feet. No external RF components are required except an antenna , making design and integration straightforward, even for engineers without previous RF experience. • Low cost 5,000bps • No external RF components • Wide supply range to required 5.2VDC • Ultra-low power consumption • Direct serial interface • Compact surface-mount package • Low harmonics • Stable SAW-based architecture • No production tuning • Supports data ranges to • Remote control • Keyless entry • Garage/gate openers • Lighting control • Medical monitoring/call systems • • Remote industrial monitoring • Periodic data transfer Home/industrial automation Fire/security alarms Remote status/position sensing Long-range RFID Wire elimination Ordering Information Ordering Information TXM-315-LC 315MHz Transmitter TXM-418-LC 418MHz Transmitter TXM-433-LC 433MHz Transmitter EVAL-***-LC LC Series Basic Evaluation Kit *** = 315, 418 Standard , 433MHz Transmitters are supplied in tubes of 50 pcs. Figure 2 Ordering Information Absolute Maximum Ratings Absolute Maximum Ratings Supply Voltage Vcc Any Input or Output Pin Operating Temperature −30 VDC ºC Storage Temperature −45 Soldering Temperature +260ºC for 10 seconds Exceeding any of the limits of this section may lead to permanent damage to the device. Furthermore, extended operation at these maximum ratings may reduce the life of this device. Figure 3 Absolute Maximum Ratings Warning This product incorporates numerous static-sensitive components. Always wear an ESD wrist strap and observe proper ESD handling procedures when working with this device. Failure to observe this precaution may result in module damage or failure. Electrical Specifications LC Series Transmitter Specifications Parameter Symbol Min. Power Supply Operating Voltage Supply Current Power Down Current Transmitter Section lPDN Transmit Frequency TXM-315-LC TXM-418-LC TXM-433-LC Center Frequency Accuracy Output Power Harmonic Emissions Data Rate Data Input Logic Low Logic High Antenna Port RF Output Impedance ROUT Timing Transmitter Turn-On Time Transmitter Turn-Off Time Environmental Operating Temperature Range Typ. Max. Units Notes mA 1,4 315 418 5,000 bps µSec |
More datasheets: APT10SCE120B | DEMG9SNA197 | MV8R03 | MV8R01 | MAX14592EEWE+T | HFE7060-200I | RXM-315-LC-S | RXM-418-LC-S | TXM-315-LC | TXM-433-LC |
Notice: we do not provide any warranties that information, datasheets, application notes, circuit diagrams, or software stored on this website are up-to-date or error free. The archived TXM-418-LC Datasheet file may be downloaded here without warranties.