EVM-915-250
Part | Datasheet |
---|---|
![]() |
EVM-915-250-BZR (pdf) |
Related Parts | Information |
---|---|
![]() |
EVM-915-250-BZS |
PDF Datasheet Preview |
---|
EVM-915-250 Data Guide Table of Contents 1 Description 2 Ordering Information 2 Electrical Specifications 4 Pin Assignments 5 Pin Descriptions 6 PCB Footprint 7 Schematic Diagram 8 Usage Guidelines for FCC Compliance 8 Antenna Selection 8 Module Modification 8 End Product Labeling Requirements 9 Additional FCC Testing Requirements 10 FCC Statements of Modular Compliance 11 Customer FCC Warning Requirements EVM-915-250 Data Guide Preliminary The EVM-915-250 evaluation module supports developments with the TRM- 915-R250 embedded radio module. The EVM-915-250 module combines a state-of-the art low power wireless transceiver with a powerful multipoint- Figure 1 EVM-915-250-FCx to-multipoint protocol controller to form a complete wireless communication solution. With a simple UART interface, a 130dB link budget and very low power operation modes. The module is excellent for Automatic Meter Reading AMR , fleet management, RFID, gas and oil sensing, Home Automation, and many other cable replacement applications requiring long range and long battery life. The module can operate as a transparent wire replacement solution. It can also operate in a peer-to-peer networked mode that supports node addressing and assured delivery. The module is designed to be totally transparent. Data is validated using an internally generated CRC-16 and encoded using a proprietary Frequency Hopping Spread Spectrum algorithm. Multiple modules can operate on the same channel because of the built-in carrier-sense-multiple-access CSMA protocol. Ordering Information Ordering Information Product Part No. Description Radiotronix Part No. TRM-915-R250 Evaluation Module, EVM-915-250-FCR Right Angle RP-SMA Connector, Wi.232FHSS-250-FCC-RA-R FCC Approved TRM-915-R250 Evaluation Module, EVM-915-250-FCS Straight RP-SMA Connector, Wi.232FHSS-250-FCC-ST-R FCC Approved TRM-915-R250 Evaluation Module, EVM-915-250-BZR Right Angle RP-SMA Connector, Wi.232FHSS-250B-RA-R Brazil Anatel Approved TRM-915-R250 Evaluation Module, EVM-915-250-BZS Straight RP-SMA Connector, Wi.232FHSS-250B-ST-R Brazil Anatel Approved TRM-915-R250 Evaluation Module, EVM-915-250-CFR Right Angle SP-SMA Connector, Wi.232FHSS-250-FCC-CFTC-RA-R Mexico CoFeTel Approved TRM-915-R250 Evaluation Module, EVM-915-250-CFS Straight RP-SMA Connector, Wi.232FHSS-250-FCC-CFTC-ST-R Mexico CoFeTel Approved Figure 2 Ordering Information Electrical Specifications Electrical Specifications Parameter Power Supply Operating Voltage Supply Current Receive Transmit, Po = 8dBm Transmit, Po = 23.5dBm Digital Interface Output Logic Low Logic High Designation Min. Typ. Max. Units Notes 12 VDC 25 mA 60 mA 200 mA Preliminary Draft Electrical Specifications Continuation Parameter Designation Min. Typ. Max. Units Notes Input Logic Low Logic High Environmental 0.7*VCC 0.3*VCC Operating Temperature Range Figure 3 Electrical Specifications ! Warning Linx radio frequency “RF” products may be used to control machinery or devices remotely, including machinery or devices that can cause death, bodily injuries, and/or property damage if improperly or inadvertently triggered, particularly in industrial settings or other applications implicating life-safety concerns. No Linx Technologies product is intended for use in any application without redundancies where the safety of life or property is at risk. The customers and users of devices and machinery controlled with RF products must understand and must use all appropriate safety procedures in connection with the devices, including without limitation, using appropriate safety procedures to prevent inadvertent triggering by the user of the device and using appropriate security codes to prevent triggering of the remote controlled machine or device by users of other remote controllers. All RF products are susceptible to RF interface that can prevent communication. Do not use any Linx product over the limits in this data guide. Excessive voltage or extended operation at the maximum voltage could cause product failure. Exceeding the reflow temperature profile could cause product failure which is not immediately evident. Do not make any physical or electrical modifications to any Linx product. This will void the warranty and regulatory and UL certifications and may cause product failure which is not immediately evident. Preliminary Draft Pin Assignments Figure 3 Pin Assignments Preliminary Draft Pin Descriptions Pin Descriptions Pin No. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 Name Vcc RXD0 TXD0 CTS0 COMMAND N/C N/C N/C N/C N/C GND N/C N/C N/C N/C PD5-EX RSSI AD0-CMD_RSP AD1-BE Description 4V to 12V Supply Voltage Serial Port Receive Data Serial Port Transmit Data Serial Port Clear To Send Command No Electrical Connection No Electrical Connection No Electrical Connection No Electrical Connection No Electrical Connection Analog Ground Analog Ground Analog Ground Analog Ground No Electrical Connection No Electrical Connection No Electrical Connection No Electrical Connection Exception Received Signal Strength Indicator Command Response Buffer Empty Analog Ground Analog Ground Figure 4 Pin Descriptions Preliminary Draft PCB Footprint Schematic Diagram Figure 5 PCB Footprint Preliminary Draft Figure 6 Schematic |
More datasheets: RD1-4320 | VW2X30-16IO1 | VW2X30-12IO1 | VW2X30-14IO1 | VW2X30-08IO1 | PTFA181001E V4 T500 | PTFA181001FV4XWSA1 | PTFA181001EV4R250XTMA1 | PTFA181001EV4XWSA1 | PTFA181001FV4R250FTMA1 |
Notice: we do not provide any warranties that information, datasheets, application notes, circuit diagrams, or software stored on this website are up-to-date or error free. The archived EVM-915-250-BZR Datasheet file may be downloaded here without warranties.