LTS 25-NP

LTS 25-NP Datasheet


Current Transducer LTS 25-NP

Part Datasheet
LTS 25-NP LTS 25-NP LTS 25-NP (pdf)
PDF Datasheet Preview
Current Transducer LTS 25-NP

For the electronic measurement of currents DC, AC, pulsed, mixed, with a galvanic isolation between the primary circuit high power and the secondary circuit electronic circuit .

IPN = 25 At

Electrical data
16054

IPN IPM VOUT

Primary nominal current rms

Primary current, measuring range

Output voltage Analog IP = 0

Sensitivity

N S Number of secondary turns ± %

R L Load resistance

RIM Internal measuring resistance ± %

TCRIM Temperature coefficient of R IM

VC Supply voltage ± 5 %

Current consumption VC = 5 V

Accuracy - Dynamic performance data
0 ± 80
± 0.625•IP/IPN V
mV/A
2000
ppm/K
28+IS2 + VOUT/RL m A
• Closed loop compensated multirange current transducer using the Hall effect
• Unipolar voltage supply
• Isolated plastic case recognized
according to UL 94-V0
• Compact design for PCB mounting
• Incorporated measuring resistance
• Extended measuring range.

Advantages

Accuracy I , T = 25°C

Accuracy with R IM IPN , TA = 25°C Linearity error

TCVOUT Temperature coefficient of VOUT IP = 0 - 10°C + 8 5°C - 40°C - 10°C

TCG Temperature coefficient of G
- 40°C + 85°C

Magnetic offset voltage I = 0,
after an overload of 3 x IPN
5xI PN
10 x IPN
tra t
di/dt

Reaction time 10 % of IPN Response time to 90 % of I step
di/dt accurately followed

BW Frequency bandwidth 0 - dB