CL4424
Part | Datasheet |
---|---|
![]() |
CL4424-RS232 (pdf) |
PDF Datasheet Preview |
---|
CL4424 Industrial 2.4GHz ConnexLink User’s Manual Version 11160 THOMPSON AVENUE LENEXA, KS 66215 800 492-2320 Document Information Copyright Information All brands and product names in this publication are registered trademarks or trademarks of their respective holders. This material is preliminary Information furnished by AEROCOMM in this specification is believed to be accurate. Devices sold by AEROCOMM are covered by the warranty and patent indemnification provisions appearing in its Terms of Sale only. AEROCOMM makes no warranty, express, statutory, and implied or by description, regarding the information set forth herein. AEROCOMM reserves the right to change specifications at any time and without notice. AEROCOMM products are intended for use in normal commercial applications. Applications requiring extended temperature range or unusual environmental requirements such as military, medical life-support or life-sustaining equipment are specifically not recommended without additional testing for such application. Limited Warranty For a period of one 1 year from the date of purchase, AEROCOMM warrants the transceiver against defects in materials and workmanship. AEROCOMM will not honor this warranty and this warranty will be automatically void if there has been any: 1 Tampering, signs of tampering, or opening the transceiver’s case. 2 Use of AC power adapters and cables other than those originally supplied with the transceivers. 3 Repair or attempt to repair by anyone other than an AEROCOMM authorized technician. This warranty does not cover and AEROCOMM will not be liable for, any damage or failure caused by misuse, abuse, acts of God, accidents, electrical irregularity, or other causes beyond AEROCOMM control, or claim by other than the original purchaser. 6/21/2005 FCC Information FCC Notice WARNING This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any interference received, including interference that may cause undesired operation. RF Exposure/Installation Instructions WARNING To satisfy FCC RF exposure requirements for mobile transmitting devices, this equipment must be professionally installed such that the end user is prevented from replacing the antenna with a non-approved antenna. The end user should also be prevented from being within 20cm of the antenna during normal use with the exception of hands, feet, wrists and ankles. The preceding statement must be included as a CAUTION statement in manuals for OEM products to alert users on FCC RF Exposure compliance. Caution Any change or modification not expressly approved by AeroComm could void the user’s authority to operate the equipment. 6/21/2005 Table of Contents USER’S MANUAL 1 CL4424 RF 5 OVERVIEW 5 CL4424 6 CL4424 INTERFACE 7 INTERFACING PROTOCOL 10 11 RS-485 2-WIRE HALF DUPLEX 13 HARDWARE FLOW CONTROL 14 NETWORK 15 POINT-TO-POINT 15 POINT-TO-MULTIPOINT 15 CL4424 CONFIGURATION UTILITY 16 16 CL4424 SETTINGS 16 ConnexLink 17 Optional Settings 18 PC Settings 18 Additional 18 PROGRAMMING THE CL4424 19 TROUBLESHOOTING 20 Figures Figure 1- RS-232/RS-485 CL4424 Front 7 Figure 2- RS-232 CL4424 Back View 8 Figure 3- RS-485 CL4424 Back View 8 Figure 4- CL4424 Mechanical 9 Figure 5- RS-232 Male/Female Connector Pin out 11 Figure 6- DCE to DTE 11 Figure 7- DCE to DCE Interface 13 Figure 8- Point-to-Point 15 Figure 9- Multiple Networks of Point-to-Multipoint CL4424s 15 Tables Table 1 DTE, DCE and Null Modem Signal 10 6/21/2005 CL4424 User’s Manual CL4424 RF Transceiver CL4424 transceivers support RS-232/ RS-485 2-wire Half Duplex protocols. In a cabled environment, the RS-485 protocol can tolerate high noise and push signals over long cable lengths. RS-485 cabling can also communicate as far as 4000 feet 1200m and offer multi-drop capability where up to 32 nodes can be connected. RS-232 cabling is suitable for distances less than 100 feet 30.5m and only supports point-to-point communications. CL4424 transceivers offer performance improvements over a standard cabled link. Distance and multipoint communications are greatly enhanced. A selection of RS-232/RS-485 can be made when ordering the CL4424s. Figure 1- RS-232/RS-485 CL4424 Front View Status LEDs RPSMA Antenna Connector Pwr Link Rx Tx CL4424 Status LEDs Color Green On indicates that the unit is powered up. On indicates the Client unit s and Server unit are in range of one Link another. Link LED remains activated on Server units. Client units activate the Link LED when in range of the Server unit. Green When flashing, LED indicates CL4424 unit is receiving data. When and flashing, LED indicates CL4424 unit is sending data. 6/21/2005 CL4424 User’s Manual RS-232 Pin Assignments Figure 2- RS-232 CL4424 Back View DB9 Male Connector Power Connector Input / Pin Description Output RS-485 2-wire Half Duplex Terminal Block Pin Assignments Figure 3- RS-485 CL4424 Back View Terminal Block Power Connector 1 VCC 6 mA max 2 485- 485B 3 No Connect 4 No Connect 5 485+ 485A 6 GND Note Standard power is applied through the power connector. Alternative power is available via the terminal block pins. 6/21/2005 CL4424 User’s Manual CL4424 Mechanical Diagram 9 Pin Male D-Connector Power Jack w/ dia. pin and opening, pin is PWR. J3 J4 Figure 4- CL4424 Mechanical Diagram Side View Label Recess, 3.5w x 2.0h dia. mounting holes 4 places Status LEDs Pwr Link Rx Tx |
More datasheets: KSC2001OBU | KSC2001YBU | KSC2001YTA | KSC2001GTA | APTM60A23FT1G | KPTC6F22-55SD | DAMAY15SA101 | IDT74LVC16823APAG8 | MDM-51PH023P | MDM-37SH003K |
Notice: we do not provide any warranties that information, datasheets, application notes, circuit diagrams, or software stored on this website are up-to-date or error free. The archived CL4424-RS232 Datasheet file may be downloaded here without warranties.