Jul.1.2017 Copyright 2017 HIROSE ELECTRIC CO., LTD. All Rights Reserved.
1.85mm coaxial connectors based on IEC Specifications
1.85mm Series
1.85mm coaxial connector based on IEC Specifications

IEC 61169-32

Compatible with the frequency range of up to 67GHz

RoHS-compatible

Compliant with all RoHS Directives.

Optical transmission devices, Measuring for data transmission, Radio communication equipment, Measuring instruments etc.

Product

Ratings

Nominal characteristic impedance

Rated frequency

Operating Temperature Range

DC to 65GHz

Storage Temperature Range
-55ç to +105ç 95% RH or less -55ç to +50ç 95% RH or less

Items Contact resistance Insulation resistance

Specifications

Center Less than External Less than
min.

Conditions Measured at less than 100mA Measured at 250V DC

Withstanding voltage No flashover or breakdown
300V AC for one minute

Voltage standing wave ratio

Mating Cycles

Vibration resistance

Shock resistance

Moisture resistance of temperature/humidity cycle

Temperature cycle Salt spray

V.S.W.R. Less than

Contact resistance at center Less than External Less than No broken, cracked, or loose parts No electrical discontinuity for more than 1µs. No broken, cracked, or loose parts No electrical discontinuity for more than 1µs. No broken, cracked, or loose parts Insulation resistance More than in a high humidity environment Insulation resistance More than in a dry environment No broken, cracked or loose parts

No broken, cracked or loose parts

No considerable corrosion

DC to 65GHz
500 cycles

Frequency 10 to 2000Hz, half amplitude 0.75mm, Acceleration 196m/s2, 12 cycles in each of 3 axis directions Acceleration 980m/s2, duration 6ms, Wave form half-sine wave, 3 times in each of 3 directions

Left for 10 cycles 240 hours in an environment with the temperature ranging from -10 to 65°C and the humidity ranging from 90 to

Temperature 5 cycles for a series of time periods _55ç for 30 minutes 3 minutes +105ç for 30 minutes 3 minutes Continuous 48 hour cycle in 5% salt water solution
*Measurement of voltage standing wave ratio V.S.W.R. The specified values of the voltage standing wave ratio V.S.W.R. noted above, are taken with the test set up shown in the figure below: