HV-P-SF085 measurement system D.U.T. details
Part | Datasheet |
---|---|
![]() |
HV-AT(20)-PJ (pdf) |
Related Parts | Information |
---|---|
![]() |
HV-AT(3)-PJ |
![]() |
HV-AT(6)-PJ |
![]() |
HV-AT(0)-PJ |
![]() |
HV-AT(10)-PJ |
PDF Datasheet Preview |
---|
Jul.1.2017 Copyright 2017 HIROSE ELECTRIC CO., LTD. All Rights Reserved. 1.85mm coaxial connectors based on IEC Specifications 1.85mm Series 1.85mm coaxial connector based on IEC Specifications IEC 61169-32 Compatible with the frequency range of up to 67GHz RoHS-compatible Compliant with all RoHS Directives. Optical transmission devices, Measuring for data transmission, Radio communication equipment, Measuring instruments etc. Product Ratings Nominal characteristic impedance Rated frequency Operating Temperature Range DC to 65GHz Storage Temperature Range -55ç to +105ç 95% RH or less -55ç to +50ç 95% RH or less Items Contact resistance Insulation resistance Specifications Center Less than External Less than min. Conditions Measured at less than 100mA Measured at 250V DC Withstanding voltage No flashover or breakdown 300V AC for one minute Voltage standing wave ratio Mating Cycles Vibration resistance Shock resistance Moisture resistance of temperature/humidity cycle Temperature cycle Salt spray V.S.W.R. Less than Contact resistance at center Less than External Less than No broken, cracked, or loose parts No electrical discontinuity for more than 1µs. No broken, cracked, or loose parts No electrical discontinuity for more than 1µs. No broken, cracked, or loose parts Insulation resistance More than in a high humidity environment Insulation resistance More than in a dry environment No broken, cracked or loose parts No broken, cracked or loose parts No considerable corrosion DC to 65GHz 500 cycles Frequency 10 to 2000Hz, half amplitude 0.75mm, Acceleration 196m/s2, 12 cycles in each of 3 axis directions Acceleration 980m/s2, duration 6ms, Wave form half-sine wave, 3 times in each of 3 directions Left for 10 cycles 240 hours in an environment with the temperature ranging from -10 to 65°C and the humidity ranging from 90 to Temperature 5 cycles for a series of time periods _55ç for 30 minutes 3 minutes +105ç for 30 minutes 3 minutes Continuous 48 hour cycle in 5% salt water solution *Measurement of voltage standing wave ratio V.S.W.R. The specified values of the voltage standing wave ratio V.S.W.R. noted above, are taken with the test set up shown in the figure below: Network Analyzer |
More datasheets: JN5139/Z01,518 | DDMMZ43X2SN | DR202I | MDM-25PH003M3 | MAX20070GTJ/V+ | MAX20070GTJ/V+T | CA3102R20-17SXF80 | HV-AT(3)-PJ | HV-AT(6)-PJ | HV-AT(0)-PJ |
Notice: we do not provide any warranties that information, datasheets, application notes, circuit diagrams, or software stored on this website are up-to-date or error free. The archived HV-AT(20)-PJ Datasheet file may be downloaded here without warranties.