MW010-Series Power Modules 36 Vdc to 75 Vdc Inputs 10 W
Part | Datasheet |
---|---|
![]() |
MW010B1 (pdf) |
Related Parts | Information |
---|---|
![]() |
MW010B |
![]() |
MW010BK |
![]() |
MW010A1 |
![]() |
MW010A |
![]() |
MW010C |
PDF Datasheet Preview |
---|
Data Sheet April 2008 MW010-Series Power Modules 36 Vdc to 75 Vdc Inputs 10 W n Telecommunications n Distributed power architecture n Electronic data processing The MW010-Series Power Modules are encapsulated in nonconductive cases measuring mm long, mm wide, and mm high in. x in. x in. . n Small size mm x mm x mm in. x in. x in. n Wide input voltage range 36 Vdc to 75 Vdc n Output current limiting, unlimited duration n Output overvoltage clamp n Load regulation max. MW010A, B, C n Line regulation max. MW010A, B, C n Input undervoltage lockout n Input-to-output isolation n No external filtering required n Operating ambient temperature range: °C to +85 °C n Meets FCC Class A requirements for radiated emissions n High reliability n UL* Recognized, CSA† Certified, and VDE Licensed n CE mark meets 73/23/EEC and 93/68/EEC Options n Remote on/off n Standard long pin mm ± mm in. ± in. The MW010A, B, C, BK, and CL Power Modules are dc-dc converters that operate over an input voltage range of to and provide precisely regulated dc outputs. The outputs are fully isolated from the inputs, allowing versatile polarity configurations and grounding connections. The modules have maximum power ratings of 10 W at a typical full-load efficiency of 83% 80% for the MW010A . The modules are encapsulated in nonconductive cases that mount on PC boards. In a natural convection environment, the modules are rated to full load at 85 °C with no heat sinking or external filtering. For applications requiring remote on/off, the MW010A1, B1, C1, BK1, and CL1 Power Modules are available. These modules are equivalent to the previously described modules, except for the addition of the remote on/off and associated terminal. * UL is a registered trademark of Underwriters Laboratories, Inc. † CSA is a registered trademark of Canadian Standards Associa- tion. This product is intended for integration into end-use equipment. All the required procedures for CE marking of end-use equipment should be followed. The CE mark is placed on selected products. MW010-Series Power Modules 36 Vdc to 75 Vdc Inputs 10 W Data Sheet April 2008 Absolute Maximum Ratings Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are absolute stress ratings only. Functional operation of the device is not implied at these or any other conditions in excess of those given in the operations sections of the data sheet. Exposure to absolute maximum ratings for extended periods can adversely affect device reliability. Parameter Unit Input Voltage Continuous Transient 2 ms VI, trans I/O Isolation Voltage Operating Ambient Temperature 60 ft./min. natural convec- tion Storage Temperature Tstg Electrical Specifications Unless otherwise indicated, specifications apply to all devices over all operating input voltage, resistive load, and temperature conditions. Table Input Specifications Parameter Operating Input Voltage Maximum Input Current VI = 0 V to 75 V IO = IO, max see Figure Inrush Transient Input Reflected-ripple Current, Peak-to-peak 5 Hz to 20 MHz, 12 µH source impedance TA = 25 °C see Figure 19 and Design Considerations section. Input Ripple Rejection 120 Hz Unit II, max Remote On/Off optional VI = 0 V to 75 V open collector or equivalent compatible signal referenced to terminal see Feature Descriptions, Design Considerations, and Ordering Information sections. Logic On Logic Off Module Specifications On/Off Low On/Off Voltage Logic Low Logic High Ion/off = 0 Ion/off Von/off Von/off Open Collector Switch Specifications: Leakage Current During Logic High Ion/off Von/off = 18 V Output Low Voltage During Logic Low Von/off Ion/off = 1 mA Turn-on Time MW010A, B, C IO = IO, max VO ± 1% of steady state MW010BK, CL see Figures 16, 17, and Undervoltage Lockout: Module On Module Off VUVLO VUVLO Output Overvoltage Clamp MW010A VO, clamp MW010B VO, clamp MW010C VO, clamp MW010BK VO1, clamp VO2, clamp MW010CL VO1, clamp VO2, clamp Typ Max Unit µA V Lineage Power MW010-Series Power Modules 36 Vdc to 75 Vdc Inputs 10 W Data Sheet April 2008 Characteristic Curves II, max = 625 mA INPUT CURRENT, II A INPUT VOLTAGE, VI V The remote on/off option can be ordered using a code of “1” see Ordering Information section . To turn the power module on and off, the user must supply a switch to control the voltage between the on/off terminal and the terminal Von/off . The switch can be an open collector or equivalent see Figure A logic low is Von/off = 0 V to V, during which the module is on. The maximum Ion/off during a logic low is 1 mA. The switch should maintain a logic low voltage while sinking 1 mA. During a logic high, the maximum Von/off generated by the power module is 18 V. The maximum allowable leakage current of the switch at Von/off = 18 V is 50 µA. Note A PWB trace between the on/off terminal and the terminal can be used to override the remote on/off. CAUTION: To avoid damaging the module or external circuitry, the pin must be connected to the V source before or simultaneously to connecting the on/off pin to the V source either directly or through the external on/off circuitry . Either the user-supplied switch or the override jumper should be wired into the circuit via individual traces not common with the power current path. Connect the switch or jumper at the power module terminals see Figure the switch connection in this way prevents noise from falsely triggering the remote on/off. Top view VI + Ion/off COMMON CONNECTION POINT Von/off ON/OFF 8-598 C Figure Remote On/Off Wiring Lineage Power Data Sheet April 2008 MW010-Series Power Modules 36 Vdc to 75 Vdc Inputs 10 W Safety Considerations For safety-agency approval of the system in which the power module is used, the power module must be installed in compliance with the spacing and separation requirements of the end-use safety agency standard, i.e., UL-1950, CSA EN60950. For the converter output to be considered meeting the requirements for safety extra-low voltage SELV , one of the following must be true: n All inputs are SELV and floating, with all outputs also floating. n All inputs are SELV and grounded, with all outputs also grounded. n Any non-SELV input must be provided with reinforced insulation from any other hazardous voltages, including the ac mains, and must have an SELV reliability test performed on it in combination with the converters. Inputs must meet SELV requirement. If the input meets extra-low voltage ELV requirements, then the converter’s output is considered ELV. The input to these units is to be provided with a maximum 5 A normal-blow fuse in the ungrounded lead. Design Considerations Input Filtering An internal aluminum electrolytic capacitor is used for filtering therefore, input ripple increases as temperature decreases. There is approximately two times more ripple at 0 °C than at 25 °C and eight times more ripple at °C than at 25 °C. The power module functions properly down to with no additional filtering. If needed, an external capacitor across the input with an impedance of at over the desired temperature range can be added to limit the input ripple current to the typical level given in the Input Specifications table. CAUTION: Lineage Power MW010-Series Power Modules 36 Vdc to 75 Vdc Inputs 10 W Outline Diagrams Dimensions are in millimeters and inches . Tolerances, unless otherwise indicated x.x ± mm in. , x.xx ± mm in. Single-Output Module MW010A, B, C Top View Data Sheet April 2008 Side View Bottom View 8-515 C .a Lineage Power Data Sheet April 2008 MW010-Series Power Modules 36 Vdc to 75 Vdc Inputs 10 W Outline Diagrams continued Ordering Information Input Voltage V Output Voltage V Device Code MW010A MW010B MW010C MW010BK MW010CL Comcode 106233950 106233976 106233992 106467293 106467327 Optional features maybe ordered using device code suffixes shown below. To order more than one option, list suffixes in numerical descending order followed by the suffix if desired. Option Remote On/Off Standard Long Pin mm ± mm in. ± in. Device Code Suffix 1 Please contact your Microelectronics Group Account Manager or Application Engineer for pricing and availability of options. A sia-Pacific Head qu art ers T el +65 6 41 6 4283 World W ide Headq u arters Lin eag e Po wer Co rp oratio n 30 00 Sk yline D riv e, Mes quite, T X 75149, U SA +1-800-526-7819 Outs id e U .S.A +1- 97 2-2 84 -2626 ag ep ower.co m e-m ail tech sup lin ea gep ower .co m Eu ro pe, M id dle-East an d Afric a He ad qu arters Tel +49 8 9 6089 286 Ind ia Head qu arters Tel +91 8 0 28411633 Lineage Power reserves the right to make changes to the produc t s or information contained herein without notice. No liability is ass umed as a res ult of their use or applic ation. No rights under any patent acc ompany the sale of any s uc h pr oduct s or information. 2008 Lineage Power Corpor ation, Mesquite, Texas All International Rights Res er ved. April 2008 DS96-215EPS Replaces DS96-214EPS |
More datasheets: 82-22-5924 | 82-22-5923 | DDMV-36X4S-N-A197 | BUZ31 H3045A | 366330038 | 1N4370ADO41 | BSO200N03S | DAMV-7C2S-N-K126 | MAX24287EVKIT | DCMM8W8SA197 |
Notice: we do not provide any warranties that information, datasheets, application notes, circuit diagrams, or software stored on this website are up-to-date or error free. The archived MW010B1 Datasheet file may be downloaded here without warranties.