JC100A

JC100A Datasheet


JC050A, JC075A, JC100A Power Modules dc-dc Converters 18 Vdc to 36 Vdc Input, 5 Vdc Output 50 W to 100 W

Part Datasheet
JC100A JC100A JC100A (pdf)
Related Parts Information
JC100A1 JC100A1 JC100A1
JC050A1 JC050A1 JC050A1
JC050A JC050A JC050A
PDF Datasheet Preview
Data Sheet March 2008

JC050A, JC075A, JC100A Power Modules dc-dc Converters 18 Vdc to 36 Vdc Input, 5 Vdc Output 50 W to 100 W

The JC050A, JC075A, JC100A Power Modules use advanced, surface-mount technology and deliver high-quality, efficient, compact dc-dc conversion.
n Distributed power architectures n Workstations n EDP equipment n Telecommunications

Options
n Choice of remote on/off logic configuration n Heat sink available for extended operation
n Small size mm x mm x mm in. x in. x in.
n High power density n High efficiency 85% typical n Low output noise n Constant frequency n Industry-standard pinout n Metal baseplate n 2:1 input voltage range n Overtemperature protection 100 W only n Remote sense n Remote on/off n Adjustable output voltage n Case ground pin n UL* Recognized, CSA† Certified, VDE Licensed
* UL is a registered trademark of Underwriters Laboratories, Inc. † CSA is a registered trademark of Canadian Standards Assn.

The JC050A, JC075A, JC100A Power Modules are dc-dc converters that operate over an input voltage range of 18 Vdc to 36 Vdc and provide a precisely regulated dc output. The outputs are fully isolated from the inputs, allowing versatile polarity configurations and grounding connections. The modules have maximum power ratings from 50 W to 100 W at typical full-load efficiency of

The sealed modules offer metal baseplate for excellent thermal performance. Threaded-through holes are provided to allow easy mounting or addition of a heat sink for high-temperature applications. The standard feature set includes remote sensing, output trim, and remote on/off for convenient flexibility in distributed power applications.

JC050A, JC075A, JC100A Power Modules dc-dc Converters 18 Vdc to 36 Vdc Input, 5 Vdc Output 50 W to 100 W

Data Sheet March 2008

Absolute Maximum Ratings

Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are absolute stress ratings only. Functional operation of the device is not implied at these or any other conditions in excess of those given in the operations sections of the data sheet. Exposure to absolute maximum ratings for extended periods can adversely affect device reliability.

Parameter

Unit

Input Voltage Continuous

I/O Isolation Voltage
1500

Operating Case Temperature See Thermal Considerations section.

Storage Temperature

Tstg

Electrical Specifications

Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature conditions.

Table Input Specifications

Parameter Operating Input Voltage Maximum Input Current

VI = 0 V to 36 V IO = IO, max JC050A See Figure 1 JC075A See Figure 2 JC100A See Figure

Inrush Transient Input Reflected-ripple Current, Peak-to-peak
5 Hz to 20 MHz, 12 µH source impedance see Figure Input Ripple Rejection 120 Hz

Unit

II, max

II, max

II, max
mAp-p

Fusing Considerations

CAUTION This power module is not internally fused. An input line fuse must always be used.

This encapsulated power module can be used in a wide variety of applications, ranging from simple stand-alone operation to an integrated part of a sophisticated power architecture. To preserve maximum flexibility, internal fusing is not included however, to achieve maximum safety and system protection, always use an input line fuse. The safety agencies require a normal-blow, dc fuse with a maximum rating of 20 A see Safety Considerations section . Based on the information provided in this data sheet on inrush energy and maximum dc input current, the same type of fuse with a lower rating can be used. Refer to the fuse manufacturer’s data for further information.

Lineage Power

Data Sheet March 2008

JC050A, JC075A, JC100A Power Modules dc-dc Converters 18 Vdc to 36 Vdc Input, 5 Vdc Output 50 W to 100 W
The temperature at this location should not exceed 100 °C. The output power of the module should not exceed the rated power for the module as listed in the Ordering Information table.

Although the maximum case temperature of the power modules is 100 °C, you can limit this temperature to a lower value for extremely high reliability.

For additional information on these modules, refer to the Thermal Management JC-, JFC-, JW-, and JFW-Series 50 W to 150 W Board-Mounted Power Modules Technical Note TN97-008EPS .

Lineage Power

JC050A, JC075A, JC100A Power Modules dc-dc Converters 18 Vdc to 36 Vdc Input, 5 Vdc Output 50 W to 100 W

Data Sheet March 2008

Thermal considerations continued

Heat Transfer Without Heat Sinks

Increasing airflow over the module enhances the heat transfer via convection. Figure 24 shows the maximum power that can be dissipated by the module without exceeding the maximum case temperature versus local ambient temperature TA for natural convection through 4 m/s 800 ft./min. .

Note that the natural convection condition was measured at m/s to m/s 10 ft./min. to 20 ft./min. however, systems in which these power modules may be used typically generate natural convection airflow rates of m/s 60 ft./min. due to other heat dissipating components in the system. The use of Figure 24 is shown in the following example.

POWER DISSIPATION, DP W
12 11

VI = 36 V

VI = 27 V 8

VI = 18 V
4 12345678

OUTPUT CURRENT, IO A

Figure JC050A Power Dissipation vs. Output Current
8-2220

Example What is the minimum airflow necessary for a JC100A operating at nominal line, an output current of 20 A, and a maximum ambient temperature of 40 °C?

Solution Given VI = 28 V

IO = 20 A TA = 40 °C Determine PD Use Figure PD = W Determine airflow v Use Figure v = m/s 540 ft./min.

POWER DISSIPATION, PD W
m/ s800 ft./min
m/ s700 ft./min
m/ s600 ft./min
m /5s00 ft./min
m /4s00 ft./min
m/ s300 ft./min
m/ s200 ft./min
m/ s100 ft./min
m/s NAT. CONV.
20 ft./min.
0 10 20 30 40 50 60 70 80 90 100

LOCAL AMBIENT TEMPERATURE, TA
8-1150 C .a

Figure Forced Convection Power Derating with No Heat Sink Either Orientation

POWER DISSIPATION, PD W
20 18

VI = 18 V

VI = 28 V
Ordering Information

Input Voltage
28 V 28 V 28 V 28 V 28 V 28 V

Output Voltage

Output Power 50 W 75 W 100 W 50 W 75 W 100 W

Remote On/ Off Logic negative positive

Device Code JC050A1 JC075A1 JC100A1 JC050A JC075A JC100A
8-1945

Comcode 107201634 107309999 107201675 107309858 107430340 107309924

A sia-Pacific Head qu art ers T el +65 6 41 6 4283

Wor ld W ide Headq u arters Lin eag e Po wer Co rp oratio n 30 00 Sk yline D riv e, Mes quite, T X 75149, U SA +1-800-526-7819 Outs id e U .S.A +1- 97 2-2 84 -2626 ag ep ower.co m e-m ail tech sup lin ea gep ower.co m

Eu ro pe, M id dle-East an d Afric a He ad qu arters T el +49 8 9 6089 286

Ind ia Head qu arters T el +91 8 0 28411633

Lineage Power reserves the right to m ake changes to the produc t s or information contained herein without notice. No liability is ass umed as a res ult of their use or applic ation. No rights under any patent acc ompany the sale of any s uc h pr oduct s or information.
2008 Lineage Power Corpor ation, M esquite, Texas All International Rights Res er ved.

March 2008 DS97-551EPS
More datasheets: PM125SH-560M | PM125SH-561M | PM125SH-680M | PM125SH-681M | PM125SH-820M | PM125SH-331M | IPB04N03LAT | IPB04N03LA | IPB04N03LA G | MAXQ1851-KIT#


Notice: we do not provide any warranties that information, datasheets, application notes, circuit diagrams, or software stored on this website are up-to-date or error free. The archived JC100A Datasheet file may be downloaded here without warranties.

Datasheet ID: JC100A 645674