JAHW050A and JAHW075A Power Modules dc-dc Converters 36 Vdc to 75 Vdc Input, 5 Vdc Output 50 W to 75 W
Part | Datasheet |
---|---|
![]() |
JAHW075A1 (pdf) |
PDF Datasheet Preview |
---|
Data Sheet June 2001 JAHW050A and JAHW075A Power Modules dc-dc Converters 36 Vdc to 75 Vdc Input, 5 Vdc Output 50 W to 75 W The JAHW Series Power Modules use advanced, surfacemount technology and deliver high-quality, efficient, and compact dc-dc conversion. s Distributed power architectures s Workstations s Computer equipment s Communications equipment Options s Heat sinks available for extended operation s Choice of remote on/off logic configuration s Latching protection features s Small size mm x mm x mm in. x in. x in. s High power density s Very high efficiency 90% typical s Low output noise s Constant frequency s Industry-standard pinout s Metal baseplate s 2:1 input voltage range s Overcurrent protection hiccup mode s Remote on/off s Adjustable output voltage s Remote sense s Output overvoltage protection hiccup mode s Overtemperature protection hiccup mode s Case ground pin s ISO* 9001 Certified manufacturing facilities s Meets the voltage and current requirements for ETSI 300-132-2 and complies with and is Licensed for Basic Insulation rating per EN60950 -B version only s UL† 60950 Recognized, No. 60950-00 Certified, and VDE § 0805 IEC60950, IEC950 Licensed s CE mark meets 73/23/EEC and 93/68/EEC directives** The JAHW050A and JAHW075A Power Modules are dc-dc converters that operate over an input voltage range of 36 Vdc to 75 Vdc and provide a precisely regulated dc output. The outputs are fully isolated from the inputs, allowing versatile polarity configurations and grounding connections. The modules have maximum power ratings from 50 W to 75 W at a typical full-load efficiency of The sealed modules offer a metal baseplate for excellent thermal performance. Threaded-through holes are provided to allow easy mounting or addition of a heat sink for high-temperature applications. The standard feature set includes remote sensing, output trim, and remote on/off for convenient flexibility in distributed power applications. * ISO is a registered trademark of the International Organization for Standardization. † UL is a registered trademark of Underwriters Laboratories, Inc. CSA is a registered trademark of Canadian Standards Association. § VDE is a trademark of Verband Deutscher Elektrotechniker e.V. ** This product is intended for integration into end-use equipment. All the required procedures for CE marking of end-use equipment should be followed. The CE mark is placed on selected products. JAHW050A and JAHW075A Power Modules dc-dc Converters 36 Vdc to 75 Vdc Input, 5 Vdc Output 50 W to 75 W Data Sheet June 2001 Absolute Maximum Ratings Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are absolute stress ratings only. Functional operation of the device is not implied at these or any other conditions in excess of those given in the operations sections of the data sheet. Exposure to absolute maximum ratings for extended periods can adversely affect device reliability. Parameter Unit Input Voltage Continuous Transient 100 ms VI, trans Operating Case Temperature See Thermal Considerations section. Storage Temperature Tstg I/O Isolation Voltage for 1 minute 1500 Electrical Specifications Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature conditions. Table Input Specifications Parameter Operating Input Voltage Maximum Input Current VI = 0 V to 75 V IO = IO, max JAHW050A See Figure JAHW075A See Figure Inrush Transient Input Reflected-ripple Current, Peak-to-peak 5 Hz to 20 MHz, 12 µH source impedance see Figure Input Ripple Rejection 120 Hz Unit II, max II, max mAp-p Fusing Considerations CAUTION This power module is not internally fused. An input line fuse must always be used. This encapsulated power module can be used in a wide variety of applications, ranging from simple stand-alone operation to an integrated part of a sophisticated power architecture. To preserve maximum flexibility, internal fusing is not included however, to achieve maximum safety and system protection, always use an input line fuse. The safety agencies require a normal-blow fuse with a maximum rating of 15 A see Safety Considerations section . Based on the information provided in this data sheet on inrush energy and maximum dc input current, the same type of fuse with a lower rating can be used. Refer to the fuse manufacturer’s data for further information. Tyco Electronics Corp. The temperature at this location should not exceed 100 °C. The output power of the module should not exceed the rated power for the module as listed in the Ordering Information table. Although the maximum case temperature of the power modules is 100 °C, you can limit this temperature to a lower value for extremely high reliability. Heat Transfer Without Heat Sinks Increasing airflow over the module enhances the heat transfer via convection. Figure 21 shows the maximum power that can be dissipated by the module without exceeding the maximum case temperature versus local ambient temperature TA for natural convection through 4 m/s 800 ft./min. . Note that the natural convection condition was measured at m/s to m/s 10 ft./min. to 20 ft./min. however, systems in which these power modules may be used typically generate natural convection airflow rates of m/s 60 ft./min. due to other heat dissipating components in the system. The use of Figure 21 is shown in the following example. Example What is the minimum airflow necessary for a JAHW075A operating at VI = 55 V, an output current of 15 A, and a maximum ambient temperature of 55 °C? Solution Given VI = 55 V IO = 15 A TA = 55 °C Determine PD Use Figure PD = 8 W Determine airflow v Use Figure v = m/s 100 ft./min. POWER DISSIPATION, PD W m/s 800 ft./min. m/s 600 ft./min. m/s 400 ft./min. m/s 200 ft./min. m/s 20 ft./min. NATURAL CONVECTION 0 10 20 30 40 50 60 70 80 90 100 LOCAL AMBIENT TEMPERATURE, TA °C 8-2236 F Figure JAHW050A and JAHW075A Forced Convection Power Derating with No Heat Sink Either Orientation POWER DISSIPATION, PD W VI = 75 V VI = 48 V VI = 36 V 2345678 OUTPUT CURRENT, IO A 8-2243 F Figure JAHW050A Power Dissipation vs. Output Current at 25 °C Tyco Electronics Corp. Data Sheet June 2001 JAHW050A and JAHW075A Power Modules dc-dc Converters 36 Vdc to 75 Vdc Input, 5 Vdc Output 50 W to 75 W POWER DISSIPATION, PD W CASE-TO-AMBIENT THERMAL RESISTANCE, °C/W Thermal Considerations continued Heat Transfer Without Heat Sinks continued VI = 75 V VI = 48 V VI = 36 V 3 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 OUTPUT CURRENT, IO A 8-2238 F Figure JAHW075A Power Dissipation vs. Output Current at 25 °C Heat Transfer with Heat Sinks The power modules have through-threaded, M3 x mounting holes, which enable heat sinks or cold plates to attach to the module. The mounting torque must not exceed N-m 5 in.-lb. . Thermal derating with heat sinks is expressed by using the overall thermal resistance of the module. Total module thermal resistance is defined as the maximum case temperature rise max divided by the module power dissipation PD : The location to measure case temperature TC is shown in Figure Case-to-ambient thermal resistance vs. airflow is shown, for various heat sink configurations and heights, in Figure These curves were obtained by experimental testing of heat sinks, which are offered in the product catalog. 1/2 IN. HEAT SINK Ordering Information Table Device Codes Input Voltage 48 V 48 V 48 V 48 V Output Voltage Output Power 50 W 75 W 50 W 75 W Remote On/Off Logic Negative Positive Device Code JAHW050A1 JAHW075A1 JAHW050A JAHW075A Comcode 108289430 108219312 Optional features can be ordered using the suffixes shown in Table The suffixes follow the last letter of the device code and are placed in descending order. For example, the device codes for a JAHW075A module with the following options are shown below: Positive logic JAHW075A Negative logic JAHW075A1 Table Device Options Option Negative remote on/off logic Positive remote on/off logic Approved for Basic Insulation Latching Protection Device Code Suffix Tyco Electronics Corp. JAHW050A and JAHW075A Power Modules dc-dc Converters 36 Vdc to 75 Vdc Input, 5 Vdc Output 50 W to 75 W Ordering Information continued Table Device Accessories Accessory 1/4 in. transverse kit heat sink, thermal pad, and screws 1/4 in. longitudinal kit heat sink, thermal pad, and screws 1/2 in. transverse kit heat sink, thermal pad, and screws 1/2 in. longitudinal kit heat sink, thermal pad, and screws 1 in. transverse kit heat sink, thermal pad, and screws 1 in. longitudinal kit heat sink, thermal pad, and screws 1/2 in. transverse kit heat sink, thermal pad, and screws 1/2 in. longitudinal kit heat sink, thermal pad, and screws Dimensions are in millimeters and inches . Comcode 407243989 407243997 407244706 407244714 407244722 407244730 407244748 407244755 Data Sheet June 2001 1/4 IN. 1/2 IN. 1 IN. 61 1/2 IN. 1/4 IN. 1/2 IN. 1 IN. 1/2 IN. 8-2832 F Figure Longitudinal Heat Sink Figure Transverse Heat Sink 8-2833 F Tyco Electronics Power Systems, Inc. 3000 Skyline Drive, Mesquite, TX 75149, USA +1-800-526-7819 FAX +1-888-315-5182 Outside U.S.A. +1-972-284-2626, FAX +1-972-284-2900 Tyco Electronics Corporation reserves the right to make changes to the product s or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product s or information. 2001 Tyco Electronics Power Systems, Inc., Mesquite, Texas All International Rights Reserved. Printed in U.S.A. June 2001 FDS01-063EPS Replaces DS00-232EPS & DS99-024EPS Printed on Recycled Paper |
More datasheets: LR6 G6/BF2X3 | LR6 G6/BF2X2 | LR6 G6/BF2 | LR6 G6/BF4 | LR6 G6/BL2X2 | LR6 G6/BF3 | DBM13W3PNMK52 | DEM9PLK87 | SCAN182373ASSC | SCAN182373ASSCX |
Notice: we do not provide any warranties that information, datasheets, application notes, circuit diagrams, or software stored on this website are up-to-date or error free. The archived JAHW075A1 Datasheet file may be downloaded here without warranties.