DC025 Triple Output-Series Power Modules 18 Vdc to 36 Vdc Input 25 W
Part | Datasheet |
---|---|
![]() |
DC025ACL-M (pdf) |
Related Parts | Information |
---|---|
![]() |
DC025ABK-M |
PDF Datasheet Preview |
---|
DC025 Triple Output-Series Power Modules 18 Vdc to 36 Vdc Input 25 W Data Sheet April 2009 Absolute Maximum Ratings Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are absolute stress ratings only. Functional operation of the device is not implied at these or any other conditions in excess of those given in the operations sections of the data sheet. Exposure to absolute maximum ratings for extended periods can adversely affect device reliability. Parameter Input Voltage Continuous I/O Isolation Voltage: dc Transient 1 minute Operating Case Temperature Storage Temperature Tstg Max 50 500 850 100 125 Unit V V °C °C Electrical Specifications Unless otherwise indicated, specifications apply to all modules over all operating input voltage, resistive load, and temperature conditions. Table Input Specifications Parameter Operating Input Voltage Maximum Input Current VI = 0 V to 36 V IO = IO, max see Figure Inrush Transient Input Reflected-ripple Current, Peak-to-peak 5 Hz to 20 MHz, 12 µH source impedance TC = 25 °C see Figure 18 and Design Considerations section. Input Ripple Rejection 120 Hz Unit II, max mAp-p Fusing Considerations CAUTION This power module is not internally fused. An input line fuse must always be used. This encapsulated power module can be used in a wide variety of applications, ranging from simple stand-alone operation to an integrated part of a sophisticated power architecture. To preserve maximum flexibility, internal fusing is not included however, to achieve maximum safety and system protection, always use an input line fuse. The safety agencies require a normal-blow, dc fuse with a maximum rating of 5 A in series with the ungrounded input lead. Based on the information provided in this data sheet on inrush energy and maximum dc input current, the same type of fuse with a lower rating can be used. Refer to the fuse manufacturer’s data for further information. Lineage Power Data Sheet April 2009 DC025 Triple Output-Series Power Modules 18 Vdc to 36 Vdc Input 25 W Electrical Specifications continued Table Output Specifications Parameter Output Voltage Over all operating input voltage, resistive load, and temperature conditions until end of life. See Figure Output Voltage Set Point VI = 28 V TC = 25 °C IO1 = A, IO2 = IO3 = A Output Regulation Line VI = 18 V to 36 V Load See Figures IO1 = IO, min to IO, max, IO2 = IO3 = IO, min Temperature See Figures TC = °C to +100 °C Output Ripple and Noise See Figure RMS Peak-to-peak 5 Hz to 20 MHz Output Current At IO < IO, min, the modules may exceed output ripple specifications. Output Current-limit Inception VO = 90% of VO, nom and minimum load on other outputs. See Figures Output Short-circuit Current VO = 1 V and minimum load on other outputs. Efficiency VI = 28 V TC = 25 °C see Figures 13, 14, and IO1 = A, IO2 = IO3 = A IO1 = A, IO2 = IO3 = A Device Symbol DC025ABK-M VO1 VO2 VO3 DC025ACL-M VO1 VO2 VO3 |
More datasheets: 05HV24B105K | 10HV24B104K | 10HV20B102K | 10HV20B103K | SPD11N10 | SPU11N10 | MDP-OMAP3430-11-256512R | MDP-OMAP3430-10-256512R | DCME17H5SNK126 | DC025ABK-M |
Notice: we do not provide any warranties that information, datasheets, application notes, circuit diagrams, or software stored on this website are up-to-date or error free. The archived DC025ACL-M Datasheet file may be downloaded here without warranties.