Features Fast and reliable response Suitable for reflow soldering only Compliant to RoHS directive 2002/95/EC UL approval to UL1434 for B59601A* and B59604* file number E69802
Part | Datasheet |
---|---|
![]() |
B59604A85A62 (pdf) |
Related Parts | Information |
---|---|
![]() |
B59604A90A62 |
PDF Datasheet Preview |
---|
PTC thermistors as limit temperature sensors SMD, EIA case sizes 0603 and 0805, standard series Series/Type Date: November 2010 EPCOS AG Reproduction, publication and dissemination of this publication, enclosures hereto and the information contained therein without EPCOS' prior express consent is prohibited. Limit temperature sensors, EIA sizes 0603 and 0805 Standard series Applications DC/DC converters Home appliances Dimmers Electronic ballasts Over-temperature protection of power components Secondary protection of battery packs SMPS Notebooks Sensors Features Fast and reliable response Suitable for reflow soldering only Compliant to RoHS directive 2002/95/EC UL approval to UL1434 for B59601A* and B59604* file number E69802 free tinned terminations Lead- Options Other Tsense or resistance values on request Delivery mode Blister tape case size 0805 or cardboard tape case size 0603 , 180-mm reel with 8-mm tape, taping to IEC 60286-3 Packing unit pcs. General technical data Max. operating voltage Minimum operating temperature Maximum operating temperature V Vmax V Vmax Vmax Tmin Tmax 125 °C or Tsense,1 +25 °C °C whichever is higher Electrical specifications and ordering codes Case size 0603 RR V Vmax Tsense,1 °C Tsense,1 +10 °C EIA case size 0603, standard types ±50 75 ±5 ±50 85 ±5 ±50 95 ±5 ±50 105 ±5 ±50 115 ±5 ±50 125 ±5 ±50 135 ±5 Ordering code B59601A0075A062 B59601A0085A062 B59601A0095A062 B59601A0105A062 B59601A0115A062 B59601A0125A062 B59601A0135A062 Please read Cautions and warnings and Important notes at the end of this document. Page 2 of 26 Sensors Limit temperature sensors, EIA sizes 0603 and 0805 EIA case size 0603, tight temperature tolerance types ±50 75 ±3 B59601A0075B062 ±50 85 ±3 B59601A0085B062 ±50 95 ±3 B59601A0095B062 ±50 105 ±3 B59601A0105B062 ±50 115 ±3 B59601A0115B062 ±50 125 ±3 B59601A0125B062 ±50 135 ±3 B59601A0135B062 Note: In order to limit self heating effects the electrical power during measurement should be below 4 mW for case size Please read Cautions and warnings and Important notes at the end of this document. Page 3 of 26 Sensors Limit temperature sensors, EIA sizes 0603 and 0805 Electrical specifications and ordering codes Case size 0603 and 0805 RR V Vmax Tsense °C Tsense,1 5°C Tsense,1 +5°C Tsense,1 +15°C Ordering code EIA case size 0603, high ohmic types 10000 ±50 120 4700 4700 10000 ±50 130 4700 4700 B59604A0085A062 B59604A0090A062 EIA case size 0603, tight resistance tolerance types ±15 70 ±15 55 ±15 85 ±15 105 B59602A0055B062 B59603A0055A062 B59603A0085A062 B59603A0105A062 EIA case size 0805, standard types ±50 70 B59701A0070A062 ±50 90 B59701A0090A062 ±50 100 B59701A0100A062 ±50 110 B59701A0110A062 ±50 120 B59701A0120A062 ±50 130 B59701A0130A062 ±50 140 B59701A0140A062 Note: In order to limit self heating effects the electrical power during measurement should be below 4 mW for case size 0603 and below 6 mW for case size Please read Cautions and warnings and Important notes at the end of this document. Page 4 of 26 Sensors Limit temperature sensors, EIA sizes 0603 and 0805 Standard series 1 R Tsense,1 +25 °C Dimensional drawings in mm EIA case size 0603 Surface-mount devices * To be replaced by a number in ordering codes, type designations etc. + To be replaced by a letter All dimensions are given in mm. The commas used in numerical values denote decimal points. Important notes The following applies to all products named in this publication: Page 24 of 26 Sensors Limit temperature sensors, EIA sizes 0603 and 0805 Some parts of this publication contain statements about the suitability of our products for certain areas of application. These statements are based on our knowledge of typical requirements that are often placed on our products in the areas of application concerned. We nevertheless expressly point out that such statements cannot be regarded as binding statements about the suitability of our products for a particular customer application. As a rule, EPCOS is either unfamiliar with individual customer applications or less familiar with them than the customers themselves. For these reasons, it is always ultimately incumbent on the customer to check and decide whether an EPCOS product with the properties described in the product specification is suitable for use in a particular customer application. We also point out that in individual cases, a malfunction of electronic components or failure before the end of their usual service life cannot be completely ruled out in the current state of the art, even if they are operated as specified. In customer applications requiring a very high level of operational safety and especially in customer applications in which the malfunction or failure of an electronic component could endanger human life or health e.g. in accident prevention or lifesaving systems , it must therefore be ensured by means of suitable design of the customer application or other action taken by the customer e.g. installation of protective circuitry or redundancy that no injury or damage is sustained by third parties in the event of malfunction or failure of an electronic component. The warnings, cautions and product-specific notes must be observed. In order to satisfy certain technical requirements, some of the products described in this publication may contain substances subject to restrictions in certain jurisdictions e.g. because they are classed as hazardous . Useful information on this will be found in our Material Data Sheets on the Internet Should you have any more detailed questions, please contact our sales offices. We constantly strive to improve our products. Consequently, the products described in this publication may change from time to time. The same is true of the corresponding product specifications. Please check therefore to what extent product descriptions and specifications contained in this publication are still applicable before or when you place an order. We also reserve the right to discontinue production and delivery of products. Consequently, we cannot guarantee that all products named in this publication will always be available. The aforementioned does not apply in the case of individual agreements deviating from the foregoing for customer-specific products. Unless otherwise agreed in individual contracts, all orders are subject to the current version of the "General Terms of Delivery for Products and Services in the Electrical Industry" published by the German Electrical and Electronics Industry Association ZVEI . The trade names EPCOS, BAOKE, Alu-X, CeraDiode, CSMP, CSSP, CTVS, DeltaCap, DigiSiMic, DSSP, FormFit, MiniBlue, MiniCell, MKK, MKD, MLSC, MotorCap, PCC, PhaseCap, PhaseCube, PhaseMod, PhiCap, SIFERRIT, SIFI, SIKOREL, SilverCap, SIMDAD, SiMic, SIMID, SineFormer, SIOV, SIP5D, SIP5K, ThermoFuse, WindCap are trademarks registered or pending in Europe and in other countries. Further information will be found on the Internet at Please read Cautions and warnings and Important notes at the end of this document. Page 25 of 26 |
More datasheets: CD4010CN | 1766 | B88069X5581T502 | 3561 | 30 PSI-G-DO-MIL | 30 INCH-D-DO-MIL | 20 INCH-D-DO-MIL | 100 PSI-G-DO-MIL | T0051317899N | B59604A90A62 |
Notice: we do not provide any warranties that information, datasheets, application notes, circuit diagrams, or software stored on this website are up-to-date or error free. The archived B59604A85A62 Datasheet file may be downloaded here without warranties.