B84263C23B13

B84263C23B13 Datasheet


B84263

Part Datasheet
B84263C23B13 B84263C23B13 B84263C23B13 (pdf)
Related Parts Information
B84263D22B13 B84263D22B13 B84263D22B13
B84263D23B13 B84263D23B13 B84263D23B13
B84263C22B13 B84263C22B13 B84263C22B13
PDF Datasheet Preview
Filters for Power Lines Low leakage current
16 to 100 A, 100 dB from 14 kHz

Series/Type:

B84263

Date January 2004

EPCOS AG Reproduction, publication and dissemination of this data sheet, enclosures hereto and the information contained therein without EPCOS' prior express consent is prohibited. Purchase orders are subject to the General Conditions for the Supply of Products and Services of the Electrical and Electronics Industry recommended by the ZVEI German Electrical and Electronic Manufacturers' Association , unless otherwise agreed.

Filters for power lines low leakage current 16 to 100 A, 100 dB from 14 kHz

B84263
2- and 4-line-filters 16 to 100 A Multi-stage Stopband attenuation 14 kHz to 40 GHz

Low volume and low voltage drop Practically no leakage current flow on the grounding conductor in normal operation because of the capacitor configuration capacitive circuit to ground only through neutral Insertion loss to CISPR 17

Design

The electrical components are incorporated in an RF-tight case of high-grade steel. The cables enter through glands. The RF-tight termination of the openings is produced by specially shaped lids. The conductors and equipment grounding conductor are connected by threaded bolts. The surface around the fixing holes is left as bare metal unpainted to ensure good RF contact with metal surfaces chassis, ground .

Protective measures grounding

The high capacitances between the lines and ground require special protective measures. If there are no product-specific requirements, protection with a secondary ground wire cross section min. 10 mm2 in accordance with EN 50178 is necessary. For this purpose the filter case have connecting bolts at each end. Resistors are incorporated in the filter to discharge capacitors after turn-off.

Scope of supply

Filters are supplied complete with all parts required for RF-tight installation fixing screws, flanges, RF gaskets, cable glands and installation instructions.

Installation

No welding is needed on the shielding wall, so any subsequent installation is quite simple. And the uniform template of the attachment points allows straightforward replacement of 2-line filters by 4-line filters for example.

Accessories and special versions

RF-tight flexible connector fittings are available for installation spaced away from the shielding wall. Filters with an EMP protection add-on for surge currents up to 100 kA per line are available on request. To match requirements, filters can be supplied with different kinds of EMC or shielding cable glands.

Tests

All filters are 100% tested and the results are archived under a filter's serial number. If required, a test report can be generated for the serial number.

Filters for power lines low leakage current 16 to 100 A, 100 dB from 14 kHz Circuit diagrams 2-line filters
4-line filters

B84263

Filters for power lines low leakage current 16 to 100 A, 100 dB from 14 kHz

Insertion loss αe typical values at Z = 50

B84263

Asymmetrical measurement circuit to MIL-STD-220A

General technical data

Rated voltage 2-line filters Rated voltage 4-line filters Rated frequency Rated current

Maximum admissible overcurrent

Test voltage

Voltage drop/phase Maximum DC resistance

VR 250

V Line/line/case

VR 440 250

V Line/line V Line/case
fR 50/60

IR See characteristics Referred to +40 °C ambient
temperature
Characteristics and ordering codes

IR Mechanical version
2-line filters 16 C 16 D 40 C 40 D
4-line filters 16 C 16 D 40 C 40 D
100 C 100 D

Rmax
< 40 < 40 < 20 < 20
< 80 < 80 < 30 < 30 <6 <6
PD Ileak Dimensional Page Approx. Ordering code
drawing
weight

W mA/V
< 18 < 2 1 < 18 < 2 < 60 < 3 < 60 < 4

B84263C0022B013 B84263D0022B013 B84263C0023B013 B84263D0023B013
< 60 < 2 5 < 60 < 2 6 < 140 < 7 < 140 < 8 < 70 < 9 < 180 < 10
10 25 11 25 12 27 13 27 14 50 15 50

B84263C1160E003 B84263D1160E003 B84263C1400E003 B84263D1400E003 B84263C1101E003 B84263D1101E003

Filters for power lines low leakage current 16 to 100 A, 100 dB from 14 kHz

Dimensional drawings Dimensional drawing 1 cable glands at both ends B84263C0022B013

B84263 2 x 16 A

Input end:

Cable gland PG 21 mounted

Shielded end:

Cable gland PG 29/21
cable gland PG 29, PG 21 and reducer ring in accessory bag

Paint color RAL 7035 light gray, semigloss

Fixing dimensions

The cable glands with cutout sealing ring are suitable for the following overall cable diameter:

PG 29 PG 21
17 to 19 mm 9 to 11 mm
20 to 22 mm 12 to 14 mm
23 to 25 mm 15 to 17 mm
26 to 28 mm 18 to 20 mm

RF-tight connection to shielding wall with connector fitting, see page

Filters for power lines low leakage current 16 to 100 A, 100 dB from 14 kHz

Dimensional drawing 2 direct connection to shielding wall B84263D0022B013

B84263 2 x 16 A

Input end:

Cable gland PG 21 mounted

Shielded end:

Cable gland PG 29/21
cable gland PG 29, PG 21 and reducer ring in accessory bag

Paint color RAL 7035 light gray, semigloss

Fixing dimensions

The cable glands with cutout sealing ring are suitable for the following overall cable diameter:

PG 29 PG 21
17 to 19 mm 9 to 11 mm
20 to 22 mm 12 to 14 mm
23 to 25 mm 15 to 17 mm
Ordering code

B84298A0042L*** B84298A0044L***

Hole in shielding wall 37 mm 54 mm

Bare metal area on shielding wall 55 +5 mm 70 +5 mm
*** add required length in cm see also chapter "Installation accessories" .

RF-tight connection to shielding wall mechanical version D

Cable gland

Parts for RF-tight mounting in accessory bag Required hole in Bare metal area
shielding wall
on shielding wall

PG 21 PG 29 PG 42

Suitable cable gland with long thread, RF gasket and check nut.
37 mm 55 +5 mm 54 mm 70 +5 mm
More datasheets: 74LVQ157SJ | 74LVQ157SJX | 74LVQ157SCX | FQD4P25TF | FQD4P25TM | FQU4P25TU | CY7C4291-10JC | CY7C4291-10JXC | BK/AGX-V-1/8 | B84263D22B13


Notice: we do not provide any warranties that information, datasheets, application notes, circuit diagrams, or software stored on this website are up-to-date or error free. The archived B84263C23B13 Datasheet file may be downloaded here without warranties.

Datasheet ID: B84263C23B13 511702