Filters for Power Lines Low leakage current 16 to 100 A, 100 dB from 14 kHz Series/Type: B84263 Date January 2004 EPCOS AG Reproduction, publication and dissemination of this data sheet, enclosures hereto and the information contained therein without EPCOS' prior express consent is prohibited. Purchase orders are subject to the General Conditions for the Supply of Products and Services of the Electrical and Electronics Industry recommended by the ZVEI German Electrical and Electronic Manufacturers' Association , unless otherwise agreed. Filters for power lines low leakage current 16 to 100 A, 100 dB from 14 kHz B84263 2- and 4-line-filters 16 to 100 A Multi-stage Stopband attenuation 14 kHz to 40 GHz Low volume and low voltage drop Practically no leakage current flow on the grounding conductor in normal operation because of the capacitor configuration capacitive circuit to ground only through neutral Insertion loss to CISPR 17 Design The electrical components are incorporated in an RF-tight case of high-grade steel. The cables enter through glands. The RF-tight termination of the openings is produced by specially shaped lids. The conductors and equipment grounding conductor are connected by threaded bolts. The surface around the fixing holes is left as bare metal unpainted to ensure good RF contact with metal surfaces chassis, ground . Protective measures grounding The high capacitances between the lines and ground require special protective measures. If there are no product-specific requirements, protection with a secondary ground wire cross section min. 10 mm2 in accordance with EN 50178 is necessary. For this purpose the filter case have connecting bolts at each end. Resistors are incorporated in the filter to discharge capacitors after turn-off. Scope of supply Filters are supplied complete with all parts required for RF-tight installation fixing screws, flanges, RF gaskets, cable glands and installation instructions. Installation No welding is needed on the shielding wall, so any subsequent installation is quite simple. And the uniform template of the attachment points allows straightforward replacement of 2-line filters by 4-line filters for example. Accessories and special versions RF-tight flexible connector fittings are available for installation spaced away from the shielding wall. Filters with an EMP protection add-on for surge currents up to 100 kA per line are available on request. To match requirements, filters can be supplied with different kinds of EMC or shielding cable glands. Tests All filters are 100% tested and the results are archived under a filter's serial number. If required, a test report can be generated for the serial number. Filters for power lines low leakage current 16 to 100 A, 100 dB from 14 kHz Circuit diagrams 2-line filters 4-line filters B84263 Filters for power lines low leakage current 16 to 100 A, 100 dB from 14 kHz Insertion loss αe typical values at Z = 50 B84263 Asymmetrical measurement circuit to MIL-STD-220A General technical data Rated voltage 2-line filters Rated voltage 4-line filters Rated frequency Rated current Maximum admissible overcurrent Test voltage Voltage drop/phase Maximum DC resistance VR 250 V Line/line/case VR 440 250 V Line/line V Line/case fR 50/60 IR See characteristics Referred to +40 °C ambient temperature Characteristics and ordering codes IR Mechanical version 2-line filters 16 C 16 D 40 C 40 D 4-line filters 16 C 16 D 40 C 40 D 100 C 100 D Rmax < 40 < 40 < 20 < 20 < 80 < 80 < 30 < 30 <6 <6 PD Ileak Dimensional Page Approx. Ordering code drawing weight W mA/V < 18 < 2 1 < 18 < 2 < 60 < 3 < 60 < 4 B84263C0022B013 B84263D0022B013 B84263C0023B013 B84263D0023B013 < 60 < 2 5 < 60 < 2 6 < 140 < 7 < 140 < 8 < 70 < 9 < 180 < 10 10 25 11 25 12 27 13 27 14 50 15 50 B84263C1160E003 B84263D1160E003 B84263C1400E003 B84263D1400E003 B84263C1101E003 B84263D1101E003 Filters for power lines low leakage current 16 to 100 A, 100 dB from 14 kHz Dimensional drawings Dimensional drawing 1 cable glands at both ends B84263C0022B013 B84263 2 x 16 A Input end: Cable gland PG 21 mounted Shielded end: Cable gland PG 29/21 cable gland PG 29, PG 21 and reducer ring in accessory bag Paint color RAL 7035 light gray, semigloss Fixing dimensions The cable glands with cutout sealing ring are suitable for the following overall cable diameter: PG 29 PG 21 17 to 19 mm 9 to 11 mm 20 to 22 mm 12 to 14 mm 23 to 25 mm 15 to 17 mm 26 to 28 mm 18 to 20 mm RF-tight connection to shielding wall with connector fitting, see page Filters for power lines low leakage current 16 to 100 A, 100 dB from 14 kHz Dimensional drawing 2 direct connection to shielding wall B84263D0022B013 B84263 2 x 16 A Input end: Cable gland PG 21 mounted Shielded end: Cable gland PG 29/21 cable gland PG 29, PG 21 and reducer ring in accessory bag Paint color RAL 7035 light gray, semigloss Fixing dimensions The cable glands with cutout sealing ring are suitable for the following overall cable diameter: PG 29 PG 21 17 to 19 mm 9 to 11 mm 20 to 22 mm 12 to 14 mm 23 to 25 mm 15 to 17 mm Ordering code B84298A0042L*** B84298A0044L*** Hole in shielding wall 37 mm 54 mm Bare metal area on shielding wall 55 +5 mm 70 +5 mm *** add required length in cm see also chapter "Installation accessories" . RF-tight connection to shielding wall mechanical version D Cable gland Parts for RF-tight mounting in accessory bag Required hole in Bare metal area shielding wall on shielding wall PG 21 PG 29 PG 42 Suitable cable gland with long thread, RF gasket and check nut. 37 mm 55 +5 mm 54 mm 70 +5 mm |
More datasheets: 74LVQ157SCX | FQD4P25TF | FQD4P25TM | FQU4P25TU | CY7C4291-10JC | CY7C4291-10JXC | BK/AGX-V-1/8 | B84263D22B13 | B84263C23B13 | B84263D23B13 |
Notice: we do not provide any warranties that information, datasheets, application notes, circuit diagrams, or software stored on this website are up-to-date or error free. The archived B84263C22B13 Datasheet file may be downloaded here without warranties.