B599*0 January 2016
Part | Datasheet |
---|---|
![]() |
B59940C0120A070 (pdf) |
PDF Datasheet Preview |
---|
PTC thermistors for overcurrent protection Leaded disks, coated, 63 V Series/Type Date: B599*0 January 2016 EPCOS AG Reproduction, publication and dissemination of this publication, enclosures hereto and the information contained therein without EPCOS' prior express consent is prohibited. EPCOS AG is a TDK Group Company. Overcurrent protection Leaded disks, coated, 63 V C910 C990 Applications Overcurrent protection Short circuit protection Features Lead-free terminals Wide range of rated currents 30 mA up to 1 A Marking Type, manufacturer's logo, reference temperature in °C and date code YYWW except B59980C0130C* and B59990C* UL approval for Tref = 120 °C and 130 °C to UL 1434 with Vmax = 65 V and VR = 63 V file number E69802 UL approval for Tref = 80 °C to UL 1434 with Vmax = 63 V and VR = 50 V file number E69802 VDE approval for selected types license number 104843 IECQ certificate for selected types file number 101-QA-2 RoHS-compatible Options Thermistors with diameter w mm are also available on tape to IEC 60286-2 Delivery mode Cardboard strips standard Cardboard tape reeled or in Ammo pack on request Dimensional drawing Dimensions mm Type Tref °C C910 130 C930 120 C930 130 C940 120 C950 80 C950 120 C950 130 C960 80 C960 120 C960 130 C970 80 C970 120 C970 130 C980 80 C980 120 C980 130 C990 80 C990 120 wmax hmax lmin 35 25 35 25 35 25 Please read Cautions and warnings and Important notes at the end of this document. Page 2 of 16 Overcurrent protection Leaded disks, coated, 63 V C910 C990 General technical data Max. operating voltage Rated voltage Switching cycles Tolerance of RR Tolerance of RR Operating temperature range Operating temperature range Operating temperature range TA = 60 °C Vmax VR N Tref = 80 °C or 120 °C Tref = 130 °C V = Vmax, Tref = 80 °C V = Vmax, Tref = 120 °C/130 °C Top V DC or V AC V DC or V AC ±25 ±20 °C °C Electrical specifications and ordering codes Type IR IS C910 1000 1500 C930 700 1400 C930 700 1100 C940 450 900 C950 320 640 C950 320 500 C960 250 500 C960 250 380 C950 170 350 C970 150 300 C970 150 240 C960 130 265 C970 90 190 C980 85 170 C980 85 130 C980 50 110 C990 50 100 C990 30 60 ISmax V = Vmax Ir typ. V = Vmax mA Tref RR typ. Rmin Approvals IECQ 130 X 120 X 130 X 120 X 120 X 130 X 120 X 130 X 120 X 130 20 X 120 25 X 130 62 X 80 25 X 120 55 X 80 55 X Ordering code B59910C0130A070 B59930C0120A070 B59930C0130A070 B59940C0120A070 B59950C0120A070 B59950C0130A070 B59960C0120A070 B59960C0130A070 B59950C0080A070 B59970C0120A070 B59970C0130A070 B59960C0080A070 B59970C0080A070 B59980C0120A070 B59980C0130A070 B59980C0080A070 B59990C0120A070 B59990C0080A070 Please read Cautions and warnings and Important notes at the end of this document. Page 3 of 16 Overcurrent protection Leaded disks, coated, 63 V C910 C990 Reliability data Test Electrical endurance, cycling Electrical endurance, constant Damp heat Standard IEC 60738-1 IEC 60738-1 IEC 60738-1 Rapid change of temperature Vibration IEC 60738-1 IEC 60738-1 Shock Climatic sequence IEC 60738-1 IEC 60738-1 Test conditions Room temperature, ISmax Vmax Number of cycles 100 Storage at Vmax and Top,max Vmax Test duration 1000 h Temperature of air 40 °C Relative humidity of air 93% Duration 56 days Test according to IEC 60068-2-78 T1 = Top,min 0 V , T2 = Top,max 0 V Number of cycles 5 Test duration 30 min Test according to IEC 60068-2-14, test Na Frequency range 10 to 55 Hz Displacement amplitude mm Test duration 3 x 2 h Test according to IEC 60068-2-6, test Fc Acceleration 400 m/s2 Pulse duration 6 ms 6 x 5000 pulses Dry heat T = Top,max 0 V Test duration 16 h Damp heat first cycle Cold T = Top,min 0 V Test duration 2 h Damp heat 5 cycles Tests performed according to IEC 60068-2-30 < 25% < 25% < 10% < 10% < 5% < 10% Please read Cautions and warnings and Important notes at the end of this document. Page 4 of 16 Overcurrent protection Leaded disks, coated, 63 V Characteristics typical for Tref = 80 °C PTC resistance RPTC versus PTC temperature TPTC measured at low signal voltage C910 C990 PTC current IPTC versus PTC voltage VPTC measured at 25 °C in still air Switching time tS versus switching current IS measured at 25 °C in still air Rated current IR versus ambient temperature TA measured in still air Please read Cautions and warnings and Important notes at the end of this document. Page 5 of 16 Overcurrent protection Leaded disks, coated, 63 V Characteristics typical for Tref = 80 °C PTC resistance RPTC versus PTC temperature TPTC measured at low signal voltage C910 C990 PTC current IPTC versus PTC voltage VPTC measured at 25 °C in still air Switching time tS versus switching current IS measured at 25 °C in still air Display of ordering codes for EPCOS products The ordering code for one and the same EPCOS product can be represented differently in data sheets, data books, other publications, on the EPCOS website, or in order-related documents such as shipping notes, order confirmations and product labels. The varying representations of the ordering codes are due to different processes employed and do not affect the specifications of the respective products. Detailed information can be found on the Internet under Please read Cautions and warnings and Important notes at the end of this document. Page 12 of 16 Overcurrent protection Leaded disks, coated, 63 V Symbols and terms Symbol A C Cth f I Imax IR Ires IPTC Ir,oil Ir,air IRMS IS ISmax LCT N Nc Nf P P25 Pel Pdiss RG Rmin RR RP RPTC Rref RS R25,match Term Area Capacitance Heat capacity Frequency Current Maximum current Rated current Residual current PTC current Residual currrent Residual currrent in oil for level sensors Residual currrent in air for level sensors Root-mean-square value of current Switching current Maximum switching current Lower category temperature Number integer Operating cycles at Vmax, charging of capacitor Switching cycles at Vmax, failure mode Power Maximum power at 25 °C Electrical power Dissipation power Generator internal resistance Minimum resistance Rated resistance rated temperature TR Tolerance of RR Parallel resistance PTC resistance Reference resistance Series resistance at 25 °C Resistance matching per reel/ packing unit at 25 °C Tolerance of R25 C910 C990 Please read Cautions and warnings and Important notes at the end of this document. Page 13 of 16 Overcurrent protection Leaded disks, coated, 63 V C910 C990 T TA TC tE TR Tsense Top TPTC tR Tref TRmin tS Tsurf UCT V or Vel Vc max VF,max VRMS VBD Vins Vlink,max Vmax,dyn Vmeas,max VR VPTC α λ Temperature Time Ambient temperature Thermal threshold time Ferroelectric Curie temperature Settling time for level sensors Rated temperature 25 °C or otherwise specified in the data sheet Sensing temperature Operating temperature PTC temperature Response time Reference temperature at minimum resistance Switching time Surface temperature Upper category temperature Voltage with subscript only for distinction from volume Maximum DC charge voltage of the surge generator Maximum voltage applied at fault conditions in protection mode Root-mean-square value of voltage Breakdown voltage Insulation test voltage Maximum link voltage Maximum operating voltage Maximum dynamic short-time operating voltage Measuring voltage Maximum measuring voltage Rated voltage drop across a PTC thermistor Temperature coefficient Tolerance, change Dissipation factor Thermal cooling time constant Failure rate Lead spacing in mm Please read Cautions and warnings and Important notes at the end of this document. Page 14 of 16 Important notes The following applies to all products named in this publication Some parts of this publication contain statements about the suitability of our products for certain areas of application. These statements are based on our knowledge of typical requirements that are often placed on our products in the areas of application concerned. We nevertheless expressly point out that such statements cannot be regarded as binding statements about the suitability of our products for a particular customer application. As a rule, EPCOS is either unfamiliar with individual customer applications or less familiar with them than the customers themselves. For these reasons, it is always ultimately incumbent on the customer to check and decide whether an EPCOS product with the properties described in the product specification is suitable for use in a particular customer application. We also point out that in individual cases, a malfunction of electronic components or failure before the end of their usual service life cannot be completely ruled out in the current state of the art, even if they are operated as specified. In customer applications requiring a very high level of operational safety and especially in customer applications in which the malfunction or failure of an electronic component could endanger human life or health e.g. in accident prevention or lifesaving systems , it must therefore be ensured by means of suitable design of the customer application or other action taken by the customer e.g. installation of protective circuitry or redundancy that no injury or damage is sustained by third parties in the event of malfunction or failure of an electronic component. The warnings, cautions and product-specific notes must be observed. In order to satisfy certain technical requirements, some of the products described in this publication may contain substances subject to restrictions in certain jurisdictions e.g. because they are classed as hazardous . Useful information on this will be found in our Material Data Sheets on the Internet Should you have any more detailed questions, please contact our sales offices. We constantly strive to improve our products. Consequently, the products described in this publication may change from time to time. The same is true of the corresponding product specifications. Please check therefore to what extent product descriptions and specifications contained in this publication are still applicable before or when you place an order. We also reserve the right to discontinue production and delivery of products. Consequently, we cannot guarantee that all products named in this publication will always be available. The aforementioned does not apply in the case of individual agreements deviating from the foregoing for customer-specific products. Unless otherwise agreed in individual contracts, all orders are subject to the current version of the "General Terms of Delivery for Products and Services in the Electrical Industry" published by the German Electrical and Electronics Industry Association ZVEI . Page 15 of 16 Important notes The trade names EPCOS, Alu-X, CeraDiode, CeraLink, CeraPad, CeraPlas, CSMP, CSSP, CTVS, DeltaCap, DigiSiMic, DSSP, ExoCore, FilterCap, FormFit, LeaXield, MiniBlue, MiniCell, MKD, MKK, MotorCap, PCC, PhaseCap, PhaseCube, PhaseMod, PhiCap, PQSine, SIFERRIT, SIFI, SIKOREL, SilverCap, SIMDAD, SiMic, SIMID, SineFormer, SIOV, SIP5D, SIP5K, TFAP, ThermoFuse, WindCap are trademarks registered or pending in Europe and in other countries. Further information will be found on the Internet at Page 16 of 16 |
More datasheets: L6R48D-120-C14 | L6R48D-090-C14 | KFF6666A | IMT4-7-F | IRM-8608S | FDC697P_F077 | FDC697P | NTCS0805E4474JXT | NTCS0805E4104JMT | NTCS0805E4334JXT |
Notice: we do not provide any warranties that information, datasheets, application notes, circuit diagrams, or software stored on this website are up-to-date or error free. The archived B59940C0120A070 Datasheet file may be downloaded here without warranties.