B59339A1201P020

B59339A1201P020 Datasheet


B593** March 2011

Part Datasheet
B59339A1201P020 B59339A1201P020 B59339A1201P020 (pdf)
PDF Datasheet Preview
PTC thermistors for switching applications

Plastic case, 110 V and 230 V

Series/Type Date:

B593** March 2011

EPCOS AG Reproduction, publication and dissemination of this publication, enclosures hereto and the information contained therein without EPCOS' prior express consent is prohibited.

Switching applications PTC thermistors in plastic case, 110 V and 230 V

Applications Delayed switching of loads For frequent switching Starting resistance in switch-mode power supplies

Features Encased thermistor disk with clamp contacts Flame-retardant plastic case material UL-listed Silver-plated lead-free solder pins Manufacturer's logo and type designation stamped on in white Stable performance throughout 100 000 switching cycles RoHS-compatible

Delivery mode Packed in blister trays

General technical data

Dimensional drawing Dimensions in mm

Switching cycles Tolerance of RR Operating temperature range Operating temperature range

V = 0 V = Vmax

N Top
±25
0/+60
Electrical specifications and ordering codes

Type RR

Rmin IR

Vmax = 160 V, VR = 110 V J282 80 50 48 100

Vmax = 265 V, VR = 230 V

J284 200 110 30

J285 320 200 24

J286 500 260 20

J289 2000 900 10

J29 5000 2000 14

J29 5000 3200 7

ISmax V = Vmax A

Ir V = Vmax mA

ISmax s

Tref typ. °C
120 190 115
Ordering code

B59339A1800P020

B59339A1201P020 B59339A1321P020 B59339A1501P020 B59339A1202P020 B59346A1502P020 B59339A1502P020

Please read Cautions and warnings and Important notes at the end of this document.

Page 2 of 12

Switching applications PTC thermistors in plastic case, 110 V and 230 V

Reliability data

Test Electrical endurance, cycling Electrical endurance, constant Damp heat

Standard IEC 60738-1

IEC 60738-1

IEC 60738-1

Rapid change of temperature

Vibration

IEC 60738-1 IEC 60738-1

Shock Climatic sequence

IEC 60738-1 IEC 60738-1

Test conditions

Room temperature, ISmax Vmax Number of cycles 50 000
< 25%

Storage at Vmax /Top,max Vmax Test duration 1000 h
< 25%

Temperature of air 40 °C Relative humidity of air 93%
< 10%

Duration 56 days

Test according to IEC 60068-2-78

T1 = Top,min 0 V , T2 = Top,max 0 V Number of cycles 5
< 10%

Test duration 30 min

Test according to IEC 60068-2-14, Test Na

Frequency range 10 to 55 Hz

Displacement amplitude mm Test duration 3 x 2 h Test according to IEC 60068-2-6, Test Fc

Acceleration 390 m/s2 Pulse duration 6 ms 6 x 4000 pulses

Dry heat T = Top,max 0 V Test duration 16 h
< 10%

Damp heat first cycle

Cold T = Top,min 0 V Test duration 2 h

Damp heat 5 cycles

Tests performed according to

IEC 60068-2-30

Please read Cautions and warnings and Important notes at the end of this document.

Page 3 of 12
Surface-mount devices * To be replaced by a number in ordering codes, type designations etc. + To be replaced by a letter All dimensions are given in mm. The commas used in numerical values denote decimal points.

Please read Cautions and warnings and Important notes at the end of this document.

Page 11 of 12

Important notes

The following applies to all products named in this publication:

Some parts of this publication contain statements about the suitability of our products for certain areas of application. These statements are based on our knowledge of typical requirements that are often placed on our products in the areas of application concerned. We nevertheless expressly point out that such statements cannot be regarded as binding statements about the suitability of our products for a particular customer application. As a rule, EPCOS is either unfamiliar with individual customer applications or less familiar with them than the customers themselves. For these reasons, it is always ultimately incumbent on the customer to check and decide whether an EPCOS product with the properties described in the product specification is suitable for use in a particular customer application.

We also point out that in individual cases, a malfunction of electronic components or failure before the end of their usual service life cannot be completely ruled out in the current state of the art, even if they are operated as specified. In customer applications requiring a very high level of operational safety and especially in customer applications in which the malfunction or failure of an electronic component could endanger human life or health e.g. in accident prevention or lifesaving systems , it must therefore be ensured by means of suitable design of the customer application or other action taken by the customer e.g. installation of protective circuitry or redundancy that no injury or damage is sustained by third parties in the event of malfunction or failure of an electronic component.

The warnings, cautions and product-specific notes must be observed. In order to satisfy certain technical requirements, some of the products described in this
publication may contain substances subject to restrictions in certain jurisdictions e.g. because they are classed as hazardous . Useful information on this will be found in our Material Data Sheets on the Internet Should you have any more detailed questions, please contact our sales offices. We constantly strive to improve our products. Consequently, the products described in this publication may change from time to time. The same is true of the corresponding product specifications. Please check therefore to what extent product descriptions and specifications contained in this publication are still applicable before or when you place an order. We also reserve the right to discontinue production and delivery of products. Consequently, we cannot guarantee that all products named in this publication will always be available. The aforementioned does not apply in the case of individual agreements deviating from the foregoing for customer-specific products. Unless otherwise agreed in individual contracts, all orders are subject to the current version of the "General Terms of Delivery for Products and Services in the Electrical Industry" published by the German Electrical and Electronics Industry Association ZVEI . The trade names EPCOS, BAOKE, Alu-X, CeraDiode, CSMP, CSSP, CTVS, DeltaCap, DigiSiMic, DSSP, FormFit, MiniBlue, MiniCell, MKK, MKD, MLSC, MotorCap, PCC, PhaseCap, PhaseCube, PhaseMod, PhiCap, SIFERRIT, SIFI, SIKOREL, SilverCap, SIMDAD, SiMic, SIMID, SineFormer, SIOV, SIP5D, SIP5K, ThermoFuse, WindCap are trademarks registered or pending in Europe and in other countries. Further information will be found on the Internet at

Page 12 of 12
More datasheets: AS1360-40-T | AS1360-30-T | AS1360-33_EK_ST | CY2CC810OXC | CY2CC810OXCT | 161A18299X | CT-1015 | BCM1122A4KEB | BCM1122A4KEBG | SK-35DT


Notice: we do not provide any warranties that information, datasheets, application notes, circuit diagrams, or software stored on this website are up-to-date or error free. The archived B59339A1201P020 Datasheet file may be downloaded here without warranties.

Datasheet ID: B59339A1201P020 511536