CT-1015

CT-1015 Datasheet


Part Datasheet
CT-1015 CT-1015 CT-1015 (pdf)
PDF Datasheet Preview
Product Type

AMGIS Part Number

Customer Part Number

Place of Manufacture

SCHEMATIC:

Current Transformer

Page 01/02

ELECTRICAL SPECIFICATION:

Volt/Amp at rated Ip for different loads

Rated input current
= 15Amps

Primary to Secondary isolation = 2500VAC

Operating Frequency Turns Ratio
= 50 / 60 Hz = 1 1000

DC Resistance

Output Voltage
= 1.5V 15A / 0.0230W

Io Vrms 1.99V
= 513µArms

Ratio Correction factor RCF* = 10% Multiply current reading by this factor to compensate for transformer losses

MECHANICAL SPECIFICAITON Pin Side View

OUTPUT RESPONSE vs INPUT CURRENT RATED BURDEN :

Front View
5±1

Marking Area

K 1 3 2
3xØ0.8

All dimensions are in mm Linear dimensional tolerance ±0.2mm

Note Un-Used pin #3

AMGIS, LLC * 10899 Kinghurst St. Ste. 220 Houston, TX 77099 Phone 832-775-1319 * Fax 832-775-1317* email:

Toll Free 877-762-6447 *

TYPICAL EXCITATION CURVE :

Page 02/02

RATIO ERROR % vs RATED BURDEN INPUT CURRENT :

TRAFO WEIGHT Approx. Weight = kg / pc

MARKING INFORMATION L01-6212 Ac yr / wk code

Dot mark for Start pin identification
-----------------Initial Issue-----------------

Balaji. R 18-Nov'2015

Changes

Issue Rev
More datasheets: AS1360-21-T | AS1360-18-T | AS1360-25-T | AS1360-50-T | AS1360-40-T | AS1360-30-T | AS1360-33_EK_ST | CY2CC810OXC | CY2CC810OXCT | 161A18299X


Notice: we do not provide any warranties that information, datasheets, application notes, circuit diagrams, or software stored on this website are up-to-date or error free. The archived CT-1015 Datasheet file may be downloaded here without warranties.

Datasheet ID: CT-1015 515972