ED Series
• AC output Solid State Relay in an Industry standard EMR plug in package
• Ratings of 3 & 5 Amps
• Load voltage range of 24-280VAC
• Fits standard DIN rail & PCB mountable sockets
• LED input status indicator
• AC or DC control
• cUL Recognized, IEC Rated, CE & RoHS Compliant
• Horsepower Rated

PRODUCT SELECTION
3-15 VDC Control 18-32 VDC Control 48-72 VDC Control 18-36 VAC Control 90-140 VAC Control

AVAILABLE OPTIONS

ED24D3 ED24C3 ED24F3

ED24D5 ED24C5 ED24F5 ED24E5 ED24B5

OUTPUT SPECIFICATIONS AC Output 1

Operating Voltage 47-63Hz [Vrms] Transient Overvoltage [Vpk] Maximum Resistive Load Current UL 508/ IEC 62314 LC-A [Arms, FLA] 2 Minimum Load Current [Arms] Maximum Off-State Leakage Current Rated Voltage [mArms] Minimum Off-State dv/dt Maximum Rated Voltage [V/µsec] 3 Maximum On-State Voltage Drop Rated Current [Vpk] Maximum Surge Current 50/60 Hz, 1 cycle [Apk] Maximum for Fusing 50/60 HZ, 1/2 cycle sec] UL 508 HP/IEC 62314 LC-B Rating 240V, 40°C [HP/KW] Minimum Power Factor with Maximum Load
24-280 600 3 500
240/250 285/260 /
24-280 600 5 500
600/625 1780/1620 /

INPUT SPECIFICATIONS 1

GENERAL SPECIFICATIONS 1

ED24Dx
3-15 VDC 3 VDC 6 VDC 500

ED24Cx
18-32 VDC 18 VDC 6 VDC 4.8K

Dielectric Strength, Input/Output 50/60Hz Minimum Insulation Resistance 500 V DC Maximum Capacitance, Input/Output

Ambient Operating Temperature Range Ambient Storage Temperature Range Weight typical Maximum Humidity Housing Material Terminals Material

Parameters
3750 Vrms 109 Ohms
10 pF
-30ºC to 80ºC -40ºC to 125ºC oz. 30 g 85% non-condensing Polyamide Class V0 UL94 Copper w/Sulfamet Nickel finish

GENERAL NOTES
1 All parameters at 25°C unless otherwise specified. 2 Based on 17mm 5A model and 13mm 3A model spacing minimum between parts.
3 Off-State dv/dt test method per EIA/NARM standard RS-443, paragraph 4 Turn-On time for Random turn-on versions is 0.1ms for DC control and 5ms for AC control.

MECHANICAL SPECIFICATIONS

ED24Fx
48-72 VDC 48 VDC 24 VDC 6 VDC 12.5K

ED24Ex
18-36 VAC 18 VAC 10 VAC N/A 4.5K 20 30

ED24Bx
90-140 VAC 90 VAC 48 VAC N/A 28K 20 30

WIRING DIAGRAM THERMAL DERATE INFORMATION

AGENCY APPROVALS

IEC 61000-4-2 Electrostatic Discharge IEC 61000-4-4 Electrically Fast Transients IEC 61000-4-5 Electrical Surges

Level 3 Criteria A Level 3 Criteria B Level 3 Criteria A