ED24D3 ED24C3 ED24F3
Part | Datasheet |
---|---|
![]() |
ED24D5 (pdf) |
Related Parts | Information |
---|---|
![]() |
ED24C3R |
![]() |
ED24B5R |
![]() |
ED24C5R |
![]() |
ED24C5 |
![]() |
ED24E5 |
![]() |
ED24D3 |
![]() |
ED24C3 |
![]() |
ED24E5R |
![]() |
ED24D3R |
![]() |
ED24B5 |
![]() |
ED24F3R |
![]() |
ED24F5R |
![]() |
ED24F5 |
![]() |
ED24F3 |
![]() |
ED24D5R |
PDF Datasheet Preview |
---|
ED Series • AC output Solid State Relay in an Industry standard EMR plug in package • Ratings of 3 & 5 Amps • Load voltage range of 24-280VAC • Fits standard DIN rail & PCB mountable sockets • LED input status indicator • AC or DC control • cUL Recognized, IEC Rated, CE & RoHS Compliant • Horsepower Rated PRODUCT SELECTION 3-15 VDC Control 18-32 VDC Control 48-72 VDC Control 18-36 VAC Control 90-140 VAC Control AVAILABLE OPTIONS ED24D3 ED24C3 ED24F3 ED24D5 ED24C5 ED24F5 ED24E5 ED24B5 OUTPUT SPECIFICATIONS AC Output 1 Operating Voltage 47-63Hz [Vrms] Transient Overvoltage [Vpk] Maximum Resistive Load Current UL 508/ IEC 62314 LC-A [Arms, FLA] 2 Minimum Load Current [Arms] Maximum Off-State Leakage Current Rated Voltage [mArms] Minimum Off-State dv/dt Maximum Rated Voltage [V/µsec] 3 Maximum On-State Voltage Drop Rated Current [Vpk] Maximum Surge Current 50/60 Hz, 1 cycle [Apk] Maximum for Fusing 50/60 HZ, 1/2 cycle sec] UL 508 HP/IEC 62314 LC-B Rating 240V, 40°C [HP/KW] Minimum Power Factor with Maximum Load 24-280 600 3 500 240/250 285/260 / 24-280 600 5 500 600/625 1780/1620 / INPUT SPECIFICATIONS 1 GENERAL SPECIFICATIONS 1 ED24Dx 3-15 VDC 3 VDC 6 VDC 500 ED24Cx 18-32 VDC 18 VDC 6 VDC 4.8K Dielectric Strength, Input/Output 50/60Hz Minimum Insulation Resistance 500 V DC Maximum Capacitance, Input/Output Ambient Operating Temperature Range Ambient Storage Temperature Range Weight typical Maximum Humidity Housing Material Terminals Material Parameters 3750 Vrms 109 Ohms 10 pF -30ºC to 80ºC -40ºC to 125ºC oz. 30 g 85% non-condensing Polyamide Class V0 UL94 Copper w/Sulfamet Nickel finish GENERAL NOTES 1 All parameters at 25°C unless otherwise specified. 2 Based on 17mm 5A model and 13mm 3A model spacing minimum between parts. 3 Off-State dv/dt test method per EIA/NARM standard RS-443, paragraph 4 Turn-On time for Random turn-on versions is 0.1ms for DC control and 5ms for AC control. MECHANICAL SPECIFICATIONS ED24Fx 48-72 VDC 48 VDC 24 VDC 6 VDC 12.5K ED24Ex 18-36 VAC 18 VAC 10 VAC N/A 4.5K 20 30 ED24Bx 90-140 VAC 90 VAC 48 VAC N/A 28K 20 30 WIRING DIAGRAM THERMAL DERATE INFORMATION AGENCY APPROVALS IEC 61000-4-2 Electrostatic Discharge IEC 61000-4-4 Electrically Fast Transients IEC 61000-4-5 Electrical Surges Level 3 Criteria A Level 3 Criteria B Level 3 Criteria A E 37 4474 ACCESSORIES |
More datasheets: 26700-203 | ED24C3R | ED24B5R | ED24C5R | ED24C5 | ED24E5 | ED24D3 | ED24C3 | ED24E5R | ED24D3R |
Notice: we do not provide any warranties that information, datasheets, application notes, circuit diagrams, or software stored on this website are up-to-date or error free. The archived ED24D5 Datasheet file may be downloaded here without warranties.