BL1R16MV1

BL1R16MV1 Datasheet


BL1R Timers

Part Datasheet
BL1R16MV1 BL1R16MV1 BL1R16MV1 (pdf)
PDF Datasheet Preview
BL1R Timers

Syrline mm - 1 Relay 16A
›› Multi-function or mono-function ›› Multi-range 12 function ›› Multi-voltage 12 V AC/DC ›› LED status indicator relay version ›› of external load connection in parallel to the
control input ›› 3-wire PNP sensor compatible

Specifications

Functions Delay

L - Li
0,1 s days

Output 1 changeover relay

Nominal rating 8A

Connections Screw terminals

Supply voltage 12 V

Code BL1R16MV1

Output relay Contact arrangement Maximum switching voltage Switching current rate resistive

Minimum switching contact Maximum switching power resistive Electrical life Maximum rate at max switching power Mechanical life Rated impulse voltage Dielectric strength between coil / contacts Dielectric strength between open contacts

Timing ranges 7 ranges

Minimum pulse duration typically relay version Maximum reset time by de-energisation typically relay version Repeatability Repetition accuracy with constant parameters Drift Temperature Voltage-dependent drift

Supply Multi-voltage power supply Operating range Operating frequency Hz
1 CO SPDT ChangeOver -Simple Pole Double Throw- 250 VAC/ 16 A resistive / 250 VDC / A resistive NO / NC 16 A 250 V AC / 16 A 30 VDC 25°C NO / NC 8 A 250 V AC / 8 A 30 VDC 60°C 10 mA / 5 VDC 4000 VA / 90 W 25°C 30x103 cycles NO at 250 VAC/ 16 A resistive 360 cycles /hour 30 x 106 cycles 5 kV 1.2/50µs IEC 60664-1 5 kV /1 min / 1 mA / 50 Hz 1 kV /1 min / 1 mA / 50 Hz

IEC 1812-1 30 ms / 100 ms with load IEC 1812-1 120 ms IEC 1812-1 ± IEC 1812-1 ± ± / °C ± / V
50 / 60 Hz ±

I Timers

I 02 I

Supply Galvanic isolation Max. absorbed power Immunity from micro power cuts General characteristics Insulation voltage, IEC 60664-1 Installation category acc. to IEC/EN 60664-1 Impulse voltage CEI/EN 60664-1 Clearance / Creepage distances Breakdown voltage Insulation resistance Status indication

Casing Fixing Symmetrical DIN rail Mounting position Housing material Protection IEC/EN 60529 Terminal capacity Single-wire without ferrule

Max. tightening torque Nm

Operating temperature range °C Storage temperature range °C Relative humidity no condensation acc. to IEC/EN 60068-2-30 Vibration resistance according to IEC/EN 60068-2-6 Impact resistance

Drop to concrete floor

Weight casing 17,5 mm

Directives

Certifications Conformity to standards

Conformity with environmental directives

Electromagnetic compatibility IEC 61000-6-2, IEC 61000-6-3, IEC 61000-6-4

Electromagnetic compatibility - Immunity to electrostatic discharges acc to IEC/EN 61000-4-2 Immunity to radiated, radio-frequency, electromagnetic field acc. IEC/EN 61000-4-3

No Approx. 3 VA W 10 ms
300 V Overvoltage category pollution degree 2 4 kV 1,2 / 50 us IEC 60664-1 3 mm / mm EN-61812-1 2,5 kV / 1 min / 1 mA / 50 Hz NFC > 500 MΩ / 250 / 1min Un green LED blinks when count, continuous ON when supplied R yellow LED continuous ON when the relay is ON DIN 43880 17,5 mm EN 50022 35 mm All positions Enclosure plastic type UL94 - V0 Housing IP40 / Terminal block IP20 IEC 60947-1 x AWG 20 12 2 x AWG 20 16 IEC 60947-1 0,5 N.m / 4,4 lbf.in IEC 60068-2 -20 °C °C IEC 60068-2 -40 °C °C without condensation ± mm from 10 Hz 2g from 60 Hz IEC 60068-2-27 15gn - 3 x 6 axis output OFF 5gn - 3 x 6 axis Output ON IEC 60068-2-32 High 0.75m 70 g 80 g with packaging 2014/30/EU EMC 2014/35/EU low voltage CE - cULus Listed Industrial Control Equipment - CCC CEI 60664-1 Insulation coordination for equipment within low-voltage systems CEI 61812-1/ Specified time relays for industrial use UL 60947-4-1/ Industrial Control Equipment NRNT- Industrial Control Switches 2015/863/UE RoHS 1907/2006 Reach 2012/19/UE WEEE Immunity for industrial environment Emission residential environment Emission industrial environment Level III Air ± 8 KV / Contact ± 6 KV

Level III 10 V/m 80 M Hz to 1 G Hz AM 1 k Hz 3 V/m 1,4 G Hz AM 1K Hz 1V/m 2 G Hz AM 1K Hz

I Timers

I 03 I

General characteristics Immunity to rapid transient bursts acc. to IEC/EN 61000-4-4 Immunity to shock waves on power supply acc. to IEC/EN 61000-4-5 Immunity to radio frequency in common mode acc. to IEC/EN 61000-4-6 Immunity to voltage dips and breaks acc. to IEC/EN 61000-4-11

Mains-borne and radiated emissions acc. to EN 55022 CISPR22 , EN55011 CISPR11 Dimensions
More datasheets: L36SA3R315NRFA | 101675-HMC221A | HMC221AE | CS4353-CZZR | CS4353-DNZ | CS4353-DZZ | CS4353-DZZR | CS4353-CZZ | BMA250 | BMA250 SHUTL


Notice: we do not provide any warranties that information, datasheets, application notes, circuit diagrams, or software stored on this website are up-to-date or error free. The archived BL1R16MV1 Datasheet file may be downloaded here without warranties.

Datasheet ID: BL1R16MV1 507146