EUL/EUH AC/DC voltage control EUH Part number 84872033
Part | Datasheet |
---|---|
![]() |
84872030 (pdf) |
Related Parts | Information |
---|---|
![]() |
84872031 |
![]() |
84872023 |
![]() |
84872034 |
![]() |
84872021 |
![]() |
84872024 |
![]() |
84872020 |
![]() |
84872033 |
PDF Datasheet Preview |
---|
22/10/2012 EUL/EUH AC/DC voltage control EUH Part number 84872033 Voltage monitoring 2 relays to cover 6 ranges of measurement 0.2V to 600V Automatic recognition AC/DC Frequency up to 500 Hz Part numbers Type 84 872 020 EUL 84 872 021 EUL 84 872 023 EUL 84 872 024 EUL 84 872 030 EUH 84 872 031 EUH 84 872 033 EUH 84 872 034 EUH Measurement range 0,2 V 0,2 V 0,2 V 0,2 V 15 V 15 V 15 V 15 V Specifications Supply voltage Un Operating range Maximum power consumption Frequency of measured signal Threshold Ue Hysteresis Display precision Delay on thresold crossing Tt Output relay Temperature Use °C Storage temperature 0C 0,85 1,15 Un 3 VA / 1 W 40 500 Hz Adjustment from 10 to 100 % of the measurement range Adjustment from 5 to 50 % of the displayed threshold ± 10 % of the full scale 0,1 3 s ±10 % 1 AgNi changeover, 8 A max -20 -30 Inputs Sensitivity Input resistance E1-M 15 to 150V E2-M 30 to 300V E3-M 60 to 600V E1-M 100kΩ E2-M 300kΩ E3-M 600kΩ Principles Supply voltage 24 V DC 24 V AC 120 V AC 230 V AC 24 V DC 24 V AC 120 V AC 230 V AC Unless otherwise specified, the characteristics given are applicable to all or part of the product range selected 22/10/2012 When the value of the controlled voltage, AC or DC, reaches the treshold Ue displayed on the front face, the output relay changes state at the end of a time delay T1, which can be set on the front face at between and 3s. Once the voltage drops below 5 to 50 % of the treshold hysteresis , the output relay changes state again instantly. Changing the hysteresis onthe front face does not therefore modify the value of the preset treshold. Legend Treshold Ue Hysteresis UPPER function UNDER function Unit power-up Controlled voltage *** TRADUCTION MANQUANTE *** Principles When the value of the controlled voltage, AC or DC, reaches the treshold Ue displayed on the front face, the output relay changes state at the end of a time delay T1, which can be set on the front face at between and 3s and remains latched in this position. Legend Treshold Ue Hysteresis UPPER function Unless otherwise specified, the characteristics given are applicable to all or part of the product range selected 22/10/2012 Dimensions mm EUL / EUH UNDER function Unit power-up Controlled voltage Connections CA EUHDU_C01 Connections CA EULH_C01 Legend *** TRADUCTION MANQUANTE *** Unless otherwise specified, the characteristics given are applicable to all or part of the product range selected 22/10/2012 |
More datasheets: 1800369 | 162C18709X | 132A15019X | 3553 | B000002 | 1802 | DM74ALS125N | DM74ALS125M | DM74ALS125MX | 84872031 |
Notice: we do not provide any warranties that information, datasheets, application notes, circuit diagrams, or software stored on this website are up-to-date or error free. The archived 84872030 Datasheet file may be downloaded here without warranties.