AA60A-036L-050D033H

AA60A-036L-050D033H Datasheet


Technical Reference Notes AA60A-036L-050D033H Series

Part Datasheet
AA60A-036L-050D033H AA60A-036L-050D033H AA60A-036L-050D033H (pdf)
PDF Datasheet Preview
Technical Reference Notes AA60A-036L-050D033H Series
5V / 3V3 Dual Output Half Brick

AA60A-036L-050D033H SERIES

This specification covers the requirement for a wide input voltage range 18V to 60V half brick - baseplate design, 60W power - dual output high efficiency DC/DC converter.

MODEL NAME AA60A-036L-050D033H AA60A-036L-050D033HN AA60A-036L-050D033H-6 AA60A-036L-050D033HN-6 AA60A-036L-050D033H-8 AA60A-036L-050D033HN-8 AA60A-036L-050D033H-6M3 AA60A-036L-050D033H-8M3 AA60A-036L-050D033H-6M4 AA60A-036L-050D033H-8M4 AA60A-036L-050D033H-6M9

VIN nominal 36V

VOUT / IOUT 5V, 12A / 3.3V, 15A 5V, 12A / 3.3V, 15A 5V, 12A / 3.3V, 15A 5V, 12A / 3.3V, 15A 5V, 12A / 3.3V, 15A 5V, 12A / 3.3V, 15A 5V, 12A / 3.3V, 15A 5V, 12A / 3.3V, 15A 5V, 12A / 3.3V, 15A 5V, 12A / 3.3V, 15A 5V, 12A / 3.3V, 15A

OPTIONS:

Negative Enable Positive Enable 3.7mm nom Pin Length:
2.8mm nom Pin Length 0.45"H - Transverse Heatsink 0.45"H - Longitudinal Heatsink

Non-threaded baseplate stand-off

SUFFIX
"N" No suffix “N” "-6"
"-8" M3 M4

SHEET 1 OF 12

Technical Reference Notes AA60A-036L-050D033H Series
5V / 3V3 Dual Output Half Brick

Electrical Specifications

STANDARD TEST CONDITION on a single module unless otherwise specified.
- VIN Case Enable:
+ VIN + VOUT2 - VOUT2 Trim2 + VOUT1 - VOUT1 Trim1:

PIN 1 PIN 2 PIN 3

PIN 4 PIN 5 PIN 6

PIN 7 PIN 8 PIN 9

PIN 10
25ºC Ambient Air

Return Pin for +VIN Case Ground - OPEN Dependent on model series1
48 VDC 3.3V Load 3.3V Load Return
3.3V Trim - Open 5V Load 5V Load Return
5V trim - Open

Note For Negative Enable series "N" suffix , Enable pin should be connected to -Vin to allow module to turnon. For Positive Enable series no "N" suffix , Enable pin should be connected to + Vin.

ABSOLUTE MAXIMUM RATINGS

Stresses in excess of the absolute maximum ratings can cause permanent damage to the converter. Functional operation of the device is converter is not implied at these or any other conditions in excess of those given in the
operational section of the specs. Exposure to absolute maximum ratings for extended period can adversely affect device reliability.

Parameter Input Voltage:

Continuous Transient 100ms :

Operating Ambient Temperature Operating Baseplate Temp erature

Storage Temperature

Operating Humidity

I/O Isolation Input to Output Input to Case Output to Case

Device Symbol
More datasheets: CS42416-DQZ | CS42416-CQZR | CS42416-DQZR | CS42416-CQZ | A8732EEETR-T | AON6786_001 | MSA-0386-BLK | MSA-0386-BLKG | MSA-0386-TR1G | MSA-0386-TR2G


Notice: we do not provide any warranties that information, datasheets, application notes, circuit diagrams, or software stored on this website are up-to-date or error free. The archived AA60A-036L-050D033H Datasheet file may be downloaded here without warranties.

Datasheet ID: AA60A-036L-050D033H 518799