EXB30 Series Dual positive output

DC/DC CONVERTERS 30W High Efficiency DC/DC Converters
• Two independent positive outputs
• Output voltage tracking
• High efficiency
• Approved to EN60950, UL1950, CSA C22.2 No. 950
• Operating ambient temperature of -40°C to +70°C
natural convection
• Up to 100% load imbalance
• Separate trim on each output
• No minimum load
• Complies with ETS 300 019-1-3/2-3
• Fully compliant with ETS 300 386-1

The EXB30 Dual series are isolated dual positive-output DC/DC converters. The products are designed using a high-efficiency synchronous rectification topology. They feature two independent fully regulated outputs, which are individually trimmable. The EXB30 Dual employs Dynamic Current Allocation such that maximum current can be drawn from either output with a total output current capability of 6A. No minimum load is required for either output. In addition, these products incorporate a tracking feature such that both outputs rise together with their output differential never exceeding Volts during start-up. A remote on/off and latching overvoltage protection for both outputs are included as standard. These latches are enabled by default, but can be disabled by the user.

All specifications are typical at nominal input, full load at 25°C unless otherwise stated
2 YEAR WARRANTY

SPECIFICATIONS

OUTPUT SPECIFICATIONS

Voltage adjustability

Both outputs
±11% min.

Voltage accuracy

Both outputs
max.

Line regulation

Low line to high line Low line to high line

Vout1 Vout2

Load regulation

Full load to no load

Minimum load

Both outputs

Ripple and noise 20MHz bandwidth
150mV pk-pk max. 30mV rms max.

Temperature coefficient
±0.02%/°C

Transient response
50% to 75% and back
peak dev. settling time to no external cap.
150mV 400µs

Short circuit protection Both outputs Isc 8A rms See Note 3

Continuous automatic recovery

Tracking

Max. differential 0.7V during start-up and in operation

INPUT SPECIFICATIONS

Input voltage range
24Vin nominal 48Vin nominal
18 to 36VDC 36 to 75VDC

Input current

No load Remote OFF
150mA max. 4mA max.