EXB30 Series Dual positive output
Part | Datasheet |
---|---|
![]() |
EXB30-24D05-3V3 (pdf) |
Related Parts | Information |
---|---|
![]() |
EXB30-48D05-3V3 |
![]() |
EXB30-48D3V3-2V5 |
PDF Datasheet Preview |
---|
EXB30 Series Dual positive output DC/DC CONVERTERS 30W High Efficiency DC/DC Converters • Two independent positive outputs • Output voltage tracking • High efficiency • Approved to EN60950, UL1950, CSA C22.2 No. 950 • Operating ambient temperature of -40°C to +70°C natural convection • Up to 100% load imbalance • Separate trim on each output • No minimum load • Complies with ETS 300 019-1-3/2-3 • Fully compliant with ETS 300 386-1 The EXB30 Dual series are isolated dual positive-output DC/DC converters. The products are designed using a high-efficiency synchronous rectification topology. They feature two independent fully regulated outputs, which are individually trimmable. The EXB30 Dual employs Dynamic Current Allocation such that maximum current can be drawn from either output with a total output current capability of 6A. No minimum load is required for either output. In addition, these products incorporate a tracking feature such that both outputs rise together with their output differential never exceeding Volts during start-up. A remote on/off and latching overvoltage protection for both outputs are included as standard. These latches are enabled by default, but can be disabled by the user. All specifications are typical at nominal input, full load at 25°C unless otherwise stated 2 YEAR WARRANTY SPECIFICATIONS OUTPUT SPECIFICATIONS Voltage adjustability Both outputs ±11% min. Voltage accuracy Both outputs max. Line regulation Low line to high line Low line to high line Vout1 Vout2 Load regulation Full load to no load Minimum load Both outputs Ripple and noise 20MHz bandwidth 150mV pk-pk max. 30mV rms max. Temperature coefficient ±0.02%/°C Transient response 50% to 75% and back peak dev. settling time to no external cap. 150mV 400µs Short circuit protection Both outputs Isc 8A rms See Note 3 Continuous automatic recovery Tracking Max. differential 0.7V during start-up and in operation INPUT SPECIFICATIONS Input voltage range 24Vin nominal 48Vin nominal 18 to 36VDC 36 to 75VDC Input current No load Remote OFF 150mA max. 4mA max. |
More datasheets: 74ACTQ74SJX | 74ACTQ74SC | FDS7088SN3 | A2D200-AA02-01 | 3128 | EKI-1526T-VDC-BE | EKI-1526-BE | EKI-1528-BE | EKI-1528T-VDC-BE | PC3566 |
Notice: we do not provide any warranties that information, datasheets, application notes, circuit diagrams, or software stored on this website are up-to-date or error free. The archived EXB30-24D05-3V3 Datasheet file may be downloaded here without warranties.