BXA10-48D12

BXA10-48D12 Datasheet


BXA10 Series Single and dual output

Part Datasheet
BXA10-48D12 BXA10-48D12 BXA10-48D12 (pdf)
Related Parts Information
BXA10-48D12-S BXA10-48D12-S BXA10-48D12-S
BXA10-12D05-S BXA10-12D05-S BXA10-12D05-S
BXA10-48D05 BXA10-48D05 BXA10-48D05
BXA10-48S05-S BXA10-48S05-S BXA10-48S05-S
BXA10-48D15 BXA10-48D15 BXA10-48D15
BXA10-12S05 BXA10-12S05 BXA10-12S05
BXA10-48S05 BXA10-48S05 BXA10-48S05
PDF Datasheet Preview
BXA10 Series Single and dual output

DC/DC CONVERTERS 8-10W Wide Input DC/DC Converters
• 1 x 2 x inch package with stand-offs
• Watts/in3 power density
• CISPR22 and EN55022 conducted emission level A
• UL, CSA and VDE approvals 48V input only
• Continuous short circuit protection
• Optional remote ON/OFF

The BXA10 series of DC/DC converters, comprising 7 different models, is designed for a wide range of applications including communications, industrial systems and mobile battery powered systems. Packing up to 10 Watts of power into a 2 x 1 x inch package, with efficiencies as high as 85%, the BXA10 has wide input ranges of 9-18VDC and 18-75VDC, and is available in single and dual output versions. Isolation of 1500VDC, approval to EN60950 2nd edition, coupled with reduced conducted noise for simplified compliance to FCC Part 15 level A and EN55022 level A, make the BXA10 ideal for telecommunications and distributed power applications. Other features include overvoltage protection, continuous short circuit protection with automatic recovery and remote on/off, all of which minimize the need for external circuitry and make the BXA10 a recommended component in distributed power systems.

All specifications are typical at nominal input, full load at 25°C unless otherwise stated
2 YEAR WARRANTY

SPECIFICATIONS

OUTPUT SPECIFICATIONS

Line regulation

LL to HL, single output LL to HL, dual output

Load regulation
10% to 100% FL See Note 4

Minimum load
48V models 12V models
10% full load No minimum load

Overshoot

At start-up
10% max.

Ripple and noise See Note 2
5Hz to 20MHz
100mV pk-pk, max. 20mV rms

Transient response
25% load step
max. dev., 250µs recovery to within

Temperature coefficient
±0.02%/°C max.

Overvoltage protection Clamp type

See table

Short circuit protection Hiccup

Continuous automatic recovery

INPUT SPECIFICATIONS

Input voltage range
12VDC See Note 6 48VDC
9 to 18VDC 18 to 75VDC

Input filter

Pi type

Start up surge current Resistive load
1.5A max.

Remote ON/OFF ON See Note 3 OFF idle current

Open collector compatible

High impedance Low impedance
More datasheets: B82462G2821M | B82462G2473M | B82462G2104M | B82462G2332M | B82462G2472M | B82462G2334M | 2979 | PWM1402B NC005 | FDPF7N50U-G | FJH1100_T50R


Notice: we do not provide any warranties that information, datasheets, application notes, circuit diagrams, or software stored on this website are up-to-date or error free. The archived BXA10-48D12 Datasheet file may be downloaded here without warranties.

Datasheet ID: BXA10-48D12 518420