Embedded Power for Business-Critical Continuity

DS1200HE
1200 Watts

Distributed Power System

Front-end Bulk Power Total Output Power 180 to 264Vac 1200W continuous 90 to 140Vac 1000W/1200W1 continuous

Special Features
• 1200W output power
• High-power
• 1U x 2U power supply
• High-density design 21.66W/in3
• Active Power Factor Correction
• EN61000-3-2 Harmonic compliance
• Inrush current control
• 80plus Platinum Efficiency
• N+1 or N+N Redundant
• Hot plug operation
• N + 1 redundant
• Active current sharing
• Full Digital control
• PMBus Compliant
• Input power reporting
• Compatible with Emerson’s Universal

Compliance
• Conducted/Radiated EMI Class B
• ROHS

Electrical Specifications

Input Voltage range:
90-140Vac 1000W / 1200W1 180-264Vac 1200W

Frequency:
47Hz - 63 Hz

Efficiency Max Input Current Inrush Current:
peak 15 Arms 55Apk at 240Vac, cold start

Conducted EMI:

Class B

Radiated EMI:

Class B

Power Factor:
typical

ITHD:

Leakage Current:
1.4mA

Hold-up Time:
12ms
Ordering Information DS1200-3 DS1200-3-002 DS1200-3-003 DS1200-3-004

Safety
• UL/cUL 60950 UL Recognized
• NEMKO+ CB Report EN60950
• CE Mark
• China CCC

Embedded Power for Business-Critical Continuity

Electrical Specifications

OUTPUTS

Main DC Output Nominal Setting:

Total Output Regulation Range Dynamic Load Regulation Range:

Output Ripple Output Current:

MIN 11.4V 11.4V

Current Sharing:

Within +/-5% of full load rating

Capacitive Loading Start-up from AC to Output:

Output Rise Time Standby DC Output VSB

Output Setpoint Range Total Output Regulation Range Dynamic Load Regulation Range:

Output Ripple Output Current Sharing Capacitive Loading Start-up from AC to Output Rise Time:

PROTECTIONS Main Output

Over-Current Protection2 Over-Voltage Protection1 Under-Voltage Protection Over-Temperature Protection:

Fan Fault Protection Standby Output

Over-Current Protection3 Over-Voltage Protection3:
2,000uF 5ms
-1% +5% +5%
120% 13.5V 10.5V
1Latch mode 2Autorecovery if the overcurrent is less than 130% and last only for <1000ms. Otherwise, latch mode 3Standby protection is auto-recovery 4For output transient testing, the minimum load shall be at 10A

NOM 12
3.3V 5.0V N/A

MAX 12.6V 12.6V 120mVp-p 100.0A
40,000uF 2000ms
50ms
1% -5% -5% 50mVp-p 6.0A 4A
680uF 1000ms
50ms
150% 15.0V 11.0V

Embedded Power for Business-Critical Continuity

Electrical Specifications

CONTROL AND STATUS SIGNALS

Input Signals

PSON_L

Active LOW signal which enables/disables the main output. Pulling this signal LOW will turn-on the main output. A 100pF decoupling capacitor is recommended at the system side.

VIL Input logic level LOW

VIH Input logiv level HIGH
More datasheets: QT100A-ISMG | AS4C32M16D2-25BCN | AS4C32M16D2-25BCNTR | AS4C32M16D2-25BINTR | AS4C32M16D2-25BIN | FJN4301RBU | DNLS412E-13 | CPH38W23MARARK9X | 50739180931600F | DS1200HE-3-002


Notice: we do not provide any warranties that information, datasheets, application notes, circuit diagrams, or software stored on this website are up-to-date or error free. The archived DS1200HE-3-004 Datasheet file may be downloaded here without warranties.

Datasheet ID: DS1200HE-3-004 511098