ALQ25B50N

ALQ25B50N Datasheet


ALQ25B50

Part Datasheet
ALQ25B50N ALQ25B50N ALQ25B50N (pdf)
PDF Datasheet Preview
Astec Industry Standard
300 Watts

ALQ25B50

DC Transfromer

Total Power Input Voltages No. of Outputs:
300W 12V 25A 48V Single

Electrical Specs

Input

Input Range1 Efficiency Over Voltage Protection Input UVLO1
42 to 53 VDC Typ 60V 39V to 42V

Special Features
• High efficiency 96% Typical
• -40°C to +100°C Ambient Air Operation
• Industry standard package Qtr Brick
x
• High capacitive load limit on start-up
• 12V 25A Intermediate Bus Voltage for

DPA application
• Regulation to zero load
• Output Enable Pin
• Meets Basic Insulation
• Input UVLO and Overvoltage Protection
• Over Temperature Protection

Environmental

Ambient air operating temperature range -40°C to +100°C

Storage temperature -55°C to +125°C

Overtemperature protection 115°C typical

MTBF > 1 million hours

Output

Output Current Line Regulation

Load Regulation Noise/Ripple2 Transient Response

Over Current Limit1 Switching Frequency

Control

Enable

Isolation Voltage

Input to Output
0A to 25A max 300W output power 10.25V to 13.60V 8.50V to 13.60V for “-AL” option ±3% Vo Typical 100mV Typical 200mV typical deviation 50% to 75% Load Change 100µs max recovery time 115% IO,MAX typical latching 800kHz

TTL compatible Positive or Negative Enable Logic
2000Vdc max
* Specifications are subject to change without notice.

Safety

UL, cUL 60950 TUV EN60950

North America USA 1-888-41-ASTEC

Europe UK 44 1384 842-211Asia HK 852-2437-9662

ALQ25B50

AMERICAS
5810 Van Allen Way Carlsbad, CA 92008 Telephone 760-930-4600 Facsimile 760-930-0698

EUROPE

Astec House, Waterfront Business Park Merry Hill, Dudley

West Midlands, DY5 1LX, UK Telephone 44 1384 842-211 Facsimile 44 1384 843-355
Ordering Information

Input Voltage

Output Voltage

Output Current

Efficiency

Model Number
42V to 53V 42V to 53V 42V to 53V 42V to 53V 36V to 53V
12.0V 12.0V 12.0V 12.0V 12.0V
25A* 25A* 25A* 25A* 25A*
96% Typ 96% Typ 96% Typ 96% Typ 96% Typ

ALQ25B50-6 ALQ25B50N-6 ALQ25B50N-AL

OPTIONS Enable Function
"N" = negative logic enable without "N" = positive logic enable default

Pin Length Option “-6” = 3.7mm nominal Standard pin length is 5mm nominal

Others
“-AL” = Autorecovery mode and lower UVLO range 34V to 36Vdc
* Derating / airflow required at elevated ambient operating temperature, consult the Technical Rreference Notes

Pin Assignments

Single Output
+ Vin Enable - Vin - Vout + Vout

Notes Part number suffix “-AL” designates:
- 36V to 53V Input voltage range - lower UVLO range 34V to 36V - Autorecovery mode after fault protection
20MHz BW limited with external 10uF tantalum cap. + 0.1uF ceramic cap across the output. 220uF low ESR cap required across the input pins.

Output may need to be derated and airflow added when operating at elvetaed ambient temperature.

All specifications are typical at nominal line, full load and 25oC ambient temp unless otherwise noted.

Technical Reference Notes should be consulted for detailed information when available.

Warranty 1yr

PIN SIDE DOWN

PIN SIDE UP

SIDE VIEW

PIN ASSIGNMENT
1 + Vin
2 Enable On/Off
3 -VIN
4 - Vout
5+ Vout

ALL DIMENSIONS ARE IN INCHES MILLIMETERS PIN PLACEMENT TOLERANCE ± MECHANICAL TOLERANCE ±

Astec Industry Standard
More datasheets: 74LVTH2240WMX | 74LVTH2240SJ | AU-Y1005-2-R | FDD6676AS | 74ACT1284MSA | 74ACT1284MTCX | 74ACT1284MSAX | 74ACT1284SCX | 74ACT1284SC | 1852


Notice: we do not provide any warranties that information, datasheets, application notes, circuit diagrams, or software stored on this website are up-to-date or error free. The archived ALQ25B50N Datasheet file may be downloaded here without warranties.

Datasheet ID: ALQ25B50N 511076