TSL2572 EVM
Part | Datasheet |
---|---|
![]() |
TSL2572EVM (pdf) |
PDF Datasheet Preview |
---|
TSL2572 EVM USER’S GUIDE TSL2572 LIGHT-TO-DIGITAL AMBIENT LIGHT SENSOR EVALUATION SYSTEM October 2012 ESTABLISHING BASIC FUNCTIONALITY 3 TSL2572 EVM GRAPHICAL USER INTERFACE GUI 4 SOFTWARE OVERVIEW 4 INPUT SIDE, “FUNCTIONAL” TAB 6 INPUT SIDE, “REGISTER” TAB 7 OUTPUT SIDE, “REGISTER” TAB 10 OUTPUT SIDE, “FUNCTIONAL” TAB 10 OUTPUT SIDE, “PLOT” 11 “LUXEQ” AND “LUXEQPLOT” TABS 12 RESOURCES 12 ams PROVIDES CUSTOMER SUPPORT IN VARIED TECHNICAL AREAS. SINCE ams DOES NOT POSSESS FULL ACCESS TO DATA CONCERNING ALL OF THE USES AND APPLICATIONS OF CUSTOMERS’ PRODUCTS, ams ASSUMES NO RESPONSIBILITY FOR CUSTOMER PRODUCT DESIGN OR THE USE OR APPLICATION OF CUSTOMERS’ PRODUCTS OR FOR ANY INFRINGEMENTS OF PATENTS OR RIGHTS OF OTHERS WHICH MAY RESULT FROM ams’ ASSISTANCE. 1 OF 12 Ambient Light Sensor INITIAL HARDWARE SETUP The software should be installed prior to connecting any hardware to the computer. Follow the instructions found in the Quick Start Guide QSG . This will load the required driver for the USB interface and also the control software and graphical user interface GUI . The hardware consists of the Controller EVM v2.1 motherboard, the TSL2572 evaluation daughterboard and a USB interface cable. When the USB cable is connected the green LED should light up indicating that power is being received via the USB interface, and the motherboard processor is running. If the green LED does not light up, check the USB cable connections unplug the USB cable and try again. If the green LED still does not light, check the PC for USB error messages. See the Resources section at the end of this document for additional assistance. ams PROVIDES CUSTOMER SUPPORT IN VARIED TECHNICAL AREAS. SINCE ams DOES NOT POSSESS FULL ACCESS TO DATA CONCERNING ALL OF THE USES AND APPLICATIONS OF CUSTOMERS’ PRODUCTS, ams ASSUMES NO RESPONSIBILITY FOR CUSTOMER PRODUCT DESIGN OR THE USE OR APPLICATION OF CUSTOMERS’ PRODUCTS OR FOR ANY INFRINGEMENTS OF PATENTS OR RIGHTS OF OTHERS WHICH MAY RESULT FROM ams’ ASSISTANCE. 2 OF 12 Ambient Light Sensor ESTABLISHING BASIC FUNCTIONALITY The software should be started using the desktop icon or by double clicking the DigitalLightSensor.exe file from the installation directory. The default installation directory, depending on the device and the operating system you are using, is: Files Windows 32 bit operating systems Windows 64 bit operating systems A different install path may be selected by the user. When started, two windows will open on the PC. The top window, or Parent Window PW , is not typically needed and may be placed out of the way. The bottom window, or Child Window CW , is the main user interface and should be positioned on the screen for easy access. Clicking on the red “X” on the PW will close both windows and terminate the application. Clicking on the red “X” on the CW will close only the CW. The “Functional” tabs on both the left and right side of the main display bottom window will be selected by default. On the right side, numbers should be changing, showing that the ALS function is operational. By changing the ambient light source or waving your hand over the sensor at <4 inch 100mm separation you should see the ALS readings change correspondingly. The balance of this document identifies and describes the controls available on the different tabs of the GUI. In combination with the TSL2572 datasheet, the QSG and application notes available on the ams website, there should be enough information to allow evaluation of the TSL2572 device. ams PROVIDES CUSTOMER SUPPORT IN VARIED TECHNICAL AREAS. SINCE ams DOES NOT POSSESS FULL ACCESS TO DATA CONCERNING ALL OF THE USES AND APPLICATIONS OF CUSTOMERS’ PRODUCTS, ams ASSUMES NO RESPONSIBILITY FOR CUSTOMER PRODUCT DESIGN OR THE USE OR APPLICATION OF CUSTOMERS’ PRODUCTS OR FOR ANY INFRINGEMENTS OF PATENTS OR RIGHTS OF OTHERS WHICH MAY RESULT FROM ams’ ASSISTANCE. 3 OF 12 Ambient Light Sensor TSL2572 EVM GRAPHICAL USER INTERFACE GUI SOFTWARE OVERVIEW On initialization the software displays two windows a smaller “Digital Light Sensor” window and a larger window containing controls pertinent to the device connected. If “No Devices” appears, verify that the daughterboard is connected to the motherboard properly. If “No_HID” appears, verify the USB cable is connected. A green LED on the motherboard indicates that the USB cable is connected and providing power to the system. The “Reset” button can be pressed, or the software can be restarted, to reinitialize the system. The larger window contains the user interface with control buttons, fields, selection boxes and output values for the identified device connected. Tabs are used to make control and evaluation of specific device functions easy. For the TSL2572 devices the initial display screen is shown: This window has inputs organized on the left, and outputs organized on the right. Values for register variables may be set using multiple techniques. The Functional tab is commonly used to quickly evaluate the device with nominal settings. The Input Register tab allows the register settings to be changed, and the Output Register tab allows registers to be viewed. Other tabs provide additional demonstration and test features for evaluation. By default the “Functional” tabs have the focus. The values shown in this document will not exactly match a users system but the basic window and controls should be identical. This document will identify the usage and operation of these items in detail. ams PROVIDES CUSTOMER SUPPORT IN VARIED TECHNICAL AREAS. SINCE ams DOES NOT POSSESS FULL ACCESS TO DATA CONCERNING ALL OF THE USES AND APPLICATIONS OF CUSTOMERS’ PRODUCTS, ams ASSUMES NO RESPONSIBILITY FOR CUSTOMER PRODUCT DESIGN OR THE USE OR APPLICATION OF CUSTOMERS’ PRODUCTS OR FOR ANY INFRINGEMENTS OF PATENTS OR RIGHTS OF OTHERS WHICH MAY RESULT FROM ams’ ASSISTANCE. 4 OF 12 Ambient Light Sensor Always visible along the bottom are the following controls • LED Off ON/OFF/ON toggle for the green motherboard LED. This LED is a good power-on indicator but can introduce errors in the optical tests. It is recommended for accurate measurements to turn the LED off. • A section containing logging controls and sampling status information: Toggles LED on the motherboard. Text entered here is appended to the default file name and stored in the log file. The file name contains the Part Name and address shown in the large “Digital Light Sensor” window, an underscore “_” and the text entered. The default if nothing is entered is a period Secondary comment box. Text entered here is also appended to the log file name and stored in the log. The default if nothing is entered is a period Sample: TMD25721Bx39 _ A-B-C _ 1-2-3 _ Log.csv |
More datasheets: 10250-55H3VC | 10226-55H3JL | D10220-55H3PC | D10220-55H3VC | DMP3120L-7 | CY7C1368C-166AXC | CY7C1368C-166AXCT | CDB1610-8W-Z | ROB0140 | AO4726 |
Notice: we do not provide any warranties that information, datasheets, application notes, circuit diagrams, or software stored on this website are up-to-date or error free. The archived TSL2572EVM Datasheet file may be downloaded here without warranties.