Part | Datasheet |
---|---|
![]() |
CT-1025 (pdf) |
PDF Datasheet Preview |
---|
Product Type AMGIS Part Number Customer Part Number Place of Manufacture SCHEMATIC: Current Transformer Page 01/02 ELECTRICAL SPECIFICATION: Volt/Amp at rated Ip for different loads Rated input current = 25Amps Primary to Secondary isolation = 2500VAC Operating Frequency Turns Ratio = 50 / 60 Hz = 1 1000 DC Resistance Output Voltage = 2.5V 25A / 0.0630W Io Vrms 3.65V = 566µArms Ratio Correction factor RCF* = 10% Multiply current reading by this factor to compensate for transformer losses MECHANICAL SPECIFICAITON Pin Side View OUTPUT RESPONSE vs INPUT CURRENT RATED BURDEN : Front View 5±1 Marking Area K 1 3 2 3xØ1.0 All dimensions are in mm Linear dimensional tolerance ±0.2mm Note Un-Used pin #3 AMGIS, LLC * 10899 Kinghurst St. Ste. 220 Houston, TX 77099 Phone 832-775-1319 * Fax 281-933-9067* email: Toll Free 877-762-6447 * TYPICAL EXCITATION CURVE : Page 02/02 RATIO ERROR % vs RATED BURDEN INPUT CURRENT : TRAFO WEIGHT Approx. Weight = kg / pc MARKING INFORMATION L01-6214 Ac yr / wk code Dot mark for Start pin identification -----------------Initial Issue----------------Changes 10 Issue Rev Balaji. R Initial 18-Nov'2015 Date |
More datasheets: H1DXH-1636G | H1DXH-1036M | H1DXS-1436G | H1DXH-1036G | H3DWH-6036M | H3DWH-6436G | H3DWH-6418M | AK8812 | ACC012 | FIN212ACGFX |