MVU18-4FL thru MVU10-14FL
Part | Datasheet |
---|---|
![]() |
MVU10-6FLK (pdf) |
Related Parts | Information |
---|---|
![]() |
MVU14-14FLK |
![]() |
MVU14-4FLK |
![]() |
MVU14-6FLK |
![]() |
MVU14-8FLK |
![]() |
MVU10-14FLK |
![]() |
MVU14-10FLK |
![]() |
MVU10-8FLK |
![]() |
MVU10-10FLK |
PDF Datasheet Preview |
---|
Scotchlok Terminals MVU18-4FL thru MVU10-14FL Locking Fork, Vinyl Insulated, Butted Seam Data Sheet Wire Maximum Product Range Stud Lock Barrel Insulation Number AWG Size Width W E Thickness Length I.D. Diameter MVU18-4FL 22-18 4 MVU18-6FL 22-18 6 MVU18-8FL 22-18 8 MVU18-10FL 22-18 10 MVU14-4FL 16-14 4 MVU14-6FL 16-14 6 MVU14-8FL 16-14 8 MVU14-10FL 16-14 10 MVU14-14FL 16-14 1/4 MVU10-6FL 12-10 6 MVU10-8FL 12-10 8 MVU10-10FL 12-10 MVU10-14FL 12-10 1/4 Installation Information LISTED 314R UNDERWRITERS LABORATORIES STANDARD NO. UL 486A 3M FILE NO. E23438 CANADIAN STANDARDS ASSOCIATION STANDARD NO. C22.2 NO. 65 3M FILE NO. LR22190 Specifications Wire Size Barrel Seam Max. Voltage Rating: Max. Temperature Rating Max. Current Insulator Material Terminal Material Plating: See Table Above Butted 600 V Building Wire 1000 V Signs, Fixtures and Luminaires Same as Wire Vinyl ETP Copper Tin WARNING Turn power off before installing or removing terminal. All electrical work should be done according to appropriate electrical codes. UL Listed and CSA Certified for use on stranded copper AWG wire only. Strip away the end 3/8 inch of wire insulation. Make the crimp in the proper station of a recommended 3M crimp tool TH-440, TH-450 scissor style , or TR-490 ratchet style hand tools. Barrel Crimp Electrical Engineering Specification Crimp-type terminals shall, electrically and mechanically, connect to a pre-stripped end of a stranded copper wire and have a flat tongue portion with a central opening for mounting around a screw or stud. The terminal line shall offer tongue variations in hole stud size 6, 8 10, etc. and configuration ring, fork, block fork, flanged block fork, locking fork, etc. and barrel variations in wire AWG size 22-18, 16-14, 12-10, etc. and construction non-insulated brazed seam, vinyl insulated butted seam, nylon insulated with insulation grip, etc. . The terminal line shall have regulatory agency coverage UL Listing, CSA Certification . The terminal tongue shall be marked with the wire range and manufacturer’s symbol The vinyl-insulated, butted seam locking fork terminal shall be tin-plated, annealed copper, with the tongue having a specified stud slot size 4 thru 1/4 in. and a butted seam barrel covered by a molded vinyl funnel entry sleeve, color coded and sized, for a specified AWG wire range 22-18, 16-14, Insulated terminals shall be UL Listed and CSA Certified for 600 Volts maximum building wire 1000 Volts maximum in signs, fixtures and luminaries and have a maximum operating temperature of 221°F 105°C . 3M and Scotchlok are trademarks of 3M |
More datasheets: DM74AS244WM | DM74AS244N | DM74AS240N | DM74AS240WM | DM74AS244SJ | DM74AS244SJX | DM74AS240WMX | AK93C41AV | MVU14-14FLK | MVU14-4FLK |
Notice: we do not provide any warranties that information, datasheets, application notes, circuit diagrams, or software stored on this website are up-to-date or error free. The archived MVU10-6FLK Datasheet file may be downloaded here without warranties.