THYRISTOR/ THYRISTOR

High Voltage Industrial Standard Package Thick Al metal die and double stick bonding Thick copper baseplate UL E78996 approved 3500VRMS isolating voltage

IRKU/V41, 56 SERIES

ADD-A-pakTM GEN V Power Modules

Up to 1600V Full compatible TO-240AA High Surge capability Easy Mounting on heatsink Al203 DBC insulator Heatsink grounded
45 A 60 A

Mechanical Description

The Generation V of Add-A-pak module combine the excellent thermal performance obtained by the usage of Direct Bonded Copper substrate with superior mechanical ruggedness, thanks to the insertion of a solid Copper baseplate at the bottom side of the device. The Cu baseplate allow an easier mounting on the majority of heatsink with increased tolerance of surface roughness and improve thermal spread. The Generation V of AAP module is manufactured without hard mold, eliminating in this way any possible direct stress on the leads.

The electrical terminals are secured against axial pull-out they are fixed to the module housing via a click-stop feature already tested and proved as reliable on other IR modules.

Electrical Description

These modules are intended for general purpose high voltage applications such as high voltage regulated power supplies, lighting circuits, temperature and motor speed control circuits, UPS and battery charger.

Major Ratings and Characteristics

Parameters IRKU/V41 IRKU/V56 Units

IT AV 85°C IT RMS ITSM 50Hz
60Hz I2t 50Hz
60Hz
45 70 850 890
60 95 1310 1370

A KA2s

VRRM range
400 to 1600

TSTG
- 40 to 125
- 40 to125

IRKU/V41, 56 Series

ELECTRICAL SPECIFICATIONS Voltage Ratings

Type number

Voltage Code

VRRM , maximum repetitive

VRSM , maximum VDRM , max. repetitive non-repetitive peak off-state voltage,

IRKU/V41, 56
400 800 1200 1600
500 900 1300 1700
400 800 1200 1600

IRRM IDRM 125°C mA

On-state Conduction

Parameters

IT AV Max. average on-state current

IT RMS Max. RMS on-state
current

ITSM Max. peak, one cycle non-repetitive on-state
Ordering Information Table

Device Code

IRK U 56 / 16 A S90

IRK.57 types With no auxiliary cathode
1 - Module type 2 - Circuit configuration See Circuit Configuration table below 3 - Current code * * 4 - Voltage code See Voltage Ratings table 5 - A Gen V 6 - dv/dt code S90 = dv/dt 1000 V/µs

No letter = dv/dt 500 Vµs

Outline Table
* * Available with no auxiliary cathode. To specify change 56 to 57 41 to 42 e.g. IRKU57/16A etc.

IRKU

Dimensions are in millimeters and [inches]

IRKV

G1 K1 K2 G2 4 5 7 6

G1 K1 K2 G2 4 5 7 6

NOTE To order the Optional Hardware see Bulletin I27900 4

Maximum Allowable Case Temperature °C
130 IRK.41.. Series R thJC DC = K/W

Maximum Average On-state Power Loss W
110 Conduction Angle
30° 60° 90° 120°
180°

Average On-state Current A

Fig. 1 - Current Ratings Characteristics
180°
120°
90°
60°
30°

RMS Limit
30 Conduction Angle

IRK.41.. Series

Per Junction

T J = 125°C

Average On-state Current A

Fig. 3 - On-state Power Loss Characteristics
800 At Any Rated Load Condition And With

Rated VRRM Applied Following Surge.

Initial TJ = 125°C 60 Hz s
50 Hz s

Peak Half Sine Wave On-state Current A

IRK.41.. Series

Per Junction