IRKU/V41, 56 SERIES
Part | Datasheet |
---|---|
![]() |
IRKU41/08A (pdf) |
Related Parts | Information |
---|---|
![]() |
IRKU41/16A |
![]() |
IRKU56/16A |
![]() |
IRKU56/12A |
![]() |
IRKU56/08A |
![]() |
IRKU56/04A |
PDF Datasheet Preview |
---|
THYRISTOR/ THYRISTOR High Voltage Industrial Standard Package Thick Al metal die and double stick bonding Thick copper baseplate UL E78996 approved 3500VRMS isolating voltage IRKU/V41, 56 SERIES ADD-A-pakTM GEN V Power Modules Up to 1600V Full compatible TO-240AA High Surge capability Easy Mounting on heatsink Al203 DBC insulator Heatsink grounded 45 A 60 A Mechanical Description The Generation V of Add-A-pak module combine the excellent thermal performance obtained by the usage of Direct Bonded Copper substrate with superior mechanical ruggedness, thanks to the insertion of a solid Copper baseplate at the bottom side of the device. The Cu baseplate allow an easier mounting on the majority of heatsink with increased tolerance of surface roughness and improve thermal spread. The Generation V of AAP module is manufactured without hard mold, eliminating in this way any possible direct stress on the leads. The electrical terminals are secured against axial pull-out they are fixed to the module housing via a click-stop feature already tested and proved as reliable on other IR modules. Electrical Description These modules are intended for general purpose high voltage applications such as high voltage regulated power supplies, lighting circuits, temperature and motor speed control circuits, UPS and battery charger. Major Ratings and Characteristics Parameters IRKU/V41 IRKU/V56 Units IT AV 85°C IT RMS ITSM 50Hz 60Hz I2t 50Hz 60Hz 45 70 850 890 60 95 1310 1370 A KA2s VRRM range 400 to 1600 TSTG - 40 to 125 - 40 to125 IRKU/V41, 56 Series ELECTRICAL SPECIFICATIONS Voltage Ratings Type number Voltage Code VRRM , maximum repetitive VRSM , maximum VDRM , max. repetitive non-repetitive peak off-state voltage, IRKU/V41, 56 400 800 1200 1600 500 900 1300 1700 400 800 1200 1600 IRRM IDRM 125°C mA On-state Conduction Parameters IT AV Max. average on-state current IT RMS Max. RMS on-state current ITSM Max. peak, one cycle non-repetitive on-state Ordering Information Table Device Code IRK U 56 / 16 A S90 IRK.57 types With no auxiliary cathode 1 - Module type 2 - Circuit configuration See Circuit Configuration table below 3 - Current code * * 4 - Voltage code See Voltage Ratings table 5 - A Gen V 6 - dv/dt code S90 = dv/dt 1000 V/µs No letter = dv/dt 500 Vµs Outline Table * * Available with no auxiliary cathode. To specify change 56 to 57 41 to 42 e.g. IRKU57/16A etc. IRKU Dimensions are in millimeters and [inches] IRKV G1 K1 K2 G2 4 5 7 6 G1 K1 K2 G2 4 5 7 6 NOTE To order the Optional Hardware see Bulletin I27900 4 Maximum Allowable Case Temperature °C 130 IRK.41.. Series R thJC DC = K/W Maximum Average On-state Power Loss W 110 Conduction Angle 30° 60° 90° 120° 180° Average On-state Current A Fig. 1 - Current Ratings Characteristics 180° 120° 90° 60° 30° RMS Limit 30 Conduction Angle IRK.41.. Series Per Junction T J = 125°C Average On-state Current A Fig. 3 - On-state Power Loss Characteristics 800 At Any Rated Load Condition And With Rated VRRM Applied Following Surge. Initial TJ = 125°C 60 Hz s 50 Hz s Peak Half Sine Wave On-state Current A IRK.41.. Series Per Junction |
More datasheets: BGF 108L E6328 | DBMY5W5P | TDA46052HKLA1 | NG88CO196EC40 | TG88CO196EC40 | IRKU41/16A | IRKU56/16A | IRKU56/12A | IRKU56/08A | IRKU56/04A |
Notice: we do not provide any warranties that information, datasheets, application notes, circuit diagrams, or software stored on this website are up-to-date or error free. The archived IRKU41/08A Datasheet file may be downloaded here without warranties.