RMX-354-1224G

RMX-354-1224G Datasheet


RMX-350

Part Datasheet
RMX-354-1224G RMX-354-1224G RMX-354-1224G (pdf)
Related Parts Information
RMX-354-1205G RMX-354-1205G RMX-354-1205G
RMX-354-1212G RMX-354-1212G RMX-354-1212G
PDF Datasheet Preview
RMX-350
350 WATTS POWER FACTOR CORRECTED MULTIPLE OUTPUT, HOT SWAP

Featuring:
• Diode isolated outputs for hot swap
• ÒZero slope program current
sharing for redundancy
• Self-aligning connector with solid
metal machined contacts
• Universal AC input
• typical power factor
• Dual converter design eliminates
interaction between logic and auxiliary outputs
• Low ripple and noise on all outputs
• DC power good and AC power fail signals
• True remote inhibit
• Monotonic turn-on and turn-off

STANDARD RMX SERIES

MODEL

PWR OUTPUT #1

OUTPUT #2

OUTPUT #3

RMX-353-0512 350 +5V 50A +12V 8/12A pk RMX-354-1205 350 +5V 50A +12V 8/12A pk RMX-354-1212 350 +5V 50A +12V 8/12A pk RMX-354-1224 350 +5V 50A +12V 8/12A pk RMX-354-1512 350 +5V 50A +15V 4A RMX-354-1524 350 +5V 50A +15V 4A

Maximum power from outputs #2, #3 and #4 to be less than 170W
-12V 4A -12V 4A -12V 4A -12V 4A -15V 4A -15V 4A

OUTPUT #4
5.2V 5A 12V 5A 24V 3A 12V 5A 24V 3A

RMX Series 350-watt power supplies provide new and increased flexibility for configuring redundant Òhot power systems using a standard product. The RMX-350 Series eliminates the need for external sheet metal sleds, OR-ing diodes, and a high current interface. These switching power supplies are power factor corrected, multiple-output units which contain built-in Schottky ORing diodes and a high current connector interface.

RMX 350 SEE

FOEQRUDIVCAINLEPNUTT

Condor D.C. Power Supplies, Inc., A subsidiary of SL Industries, Inc. 805-486-4565 800 235-5929 Fax 805 487-8911

RMX-350
lbs - kgs
350 WATTS 10.75”x 4.8”x RMX-350

Dimensions Inches Millimeters

SPECIFICATIONS ALL MODELS

INPUT AC Input 90-264 Vac continuous range, 47 to 63 Hz. Internally fused for 7A. Power Factor typical at full load. Meets EN61000-3-2. Inrush Cold startAC current is less than 30 A at 115 Vac and 60 A at 230 Vac. Limited by
thermistor. Brownout Protection Holds regulation to 85 Vac. Holdup Time 20 ms minimum after removal of power at full load. Efficiency 70% typical. AC Power Fail Provides TTL “0” 5 ms before output voltage goes out of regulation band
upon loss of AC power.

OUTPUT Adjustability Outputs #1 and 2, and 4 factory adjusted to nominal Output #3 tracks
#2 initial accuracy Line & Load Reg Outputs #1, 2, and 4 hold ±2% over AC input range and 0 to 100% load

ENVIRONMENTAL Thermal Protection Shuts down power supply if overheated. Automatic recovery. Temperature Range 0°to 50°Catfullratings. Safety Agencies Most models are approved to UL1950 CSA #234 IEC 950 and TÜV

EN60950, Class 1 SELV., CE 72/23/EEC/93/68EEC low voltage directive .

Conducted RFI Meets FCC Part 15, Subpart J, Class A EN55022 Class B CISPR 22 Class B. Output Isolation Isolatedfrom ground 50 Vdc. Cooling Self-cooled by internal ball-bearing fan.

OPTIONS

Consult factory for available options.

AC INPUT 90-264 VAC Continuous Range

FUNCTION
115 VAC
230 VAC

J1-21
More datasheets: 335104-12-0300 | 335104-12-0150 | 335104-12-0050 | KSM1131 | KSM1131ZLFG | RC1083BWHTWHTEF | RC1083BBLKBLKAF | 100ELT22MX | 100ELT22M | RMX-354-1205G


Notice: we do not provide any warranties that information, datasheets, application notes, circuit diagrams, or software stored on this website are up-to-date or error free. The archived RMX-354-1224G Datasheet file may be downloaded here without warranties.

Datasheet ID: RMX-354-1224G 506477