RMX-350
Part | Datasheet |
---|---|
![]() |
RMX-354-1212G (pdf) |
Related Parts | Information |
---|---|
![]() |
RMX-354-1205G |
![]() |
RMX-354-1224G |
PDF Datasheet Preview |
---|
RMX-350 350 WATTS POWER FACTOR CORRECTED MULTIPLE OUTPUT, HOT SWAP Featuring: • Diode isolated outputs for hot swap • ÒZero slope program current sharing for redundancy • Self-aligning connector with solid metal machined contacts • Universal AC input • typical power factor • Dual converter design eliminates interaction between logic and auxiliary outputs • Low ripple and noise on all outputs • DC power good and AC power fail signals • True remote inhibit • Monotonic turn-on and turn-off STANDARD RMX SERIES MODEL PWR OUTPUT #1 OUTPUT #2 OUTPUT #3 RMX-353-0512 350 +5V 50A +12V 8/12A pk RMX-354-1205 350 +5V 50A +12V 8/12A pk RMX-354-1212 350 +5V 50A +12V 8/12A pk RMX-354-1224 350 +5V 50A +12V 8/12A pk RMX-354-1512 350 +5V 50A +15V 4A RMX-354-1524 350 +5V 50A +15V 4A Maximum power from outputs #2, #3 and #4 to be less than 170W -12V 4A -12V 4A -12V 4A -12V 4A -15V 4A -15V 4A OUTPUT #4 5.2V 5A 12V 5A 24V 3A 12V 5A 24V 3A RMX Series 350-watt power supplies provide new and increased flexibility for configuring redundant Òhot power systems using a standard product. The RMX-350 Series eliminates the need for external sheet metal sleds, OR-ing diodes, and a high current interface. These switching power supplies are power factor corrected, multiple-output units which contain built-in Schottky ORing diodes and a high current connector interface. RMX 350 SEE FOEQRUDIVCAINLEPNUTT Condor D.C. Power Supplies, Inc., A subsidiary of SL Industries, Inc. 805-486-4565 800 235-5929 Fax 805 487-8911 RMX-350 lbs - kgs 350 WATTS 10.75”x 4.8”x RMX-350 Dimensions Inches Millimeters SPECIFICATIONS ALL MODELS INPUT AC Input 90-264 Vac continuous range, 47 to 63 Hz. Internally fused for 7A. Power Factor typical at full load. Meets EN61000-3-2. Inrush Cold startAC current is less than 30 A at 115 Vac and 60 A at 230 Vac. Limited by thermistor. Brownout Protection Holds regulation to 85 Vac. Holdup Time 20 ms minimum after removal of power at full load. Efficiency 70% typical. AC Power Fail Provides TTL “0” 5 ms before output voltage goes out of regulation band upon loss of AC power. OUTPUT Adjustability Outputs #1 and 2, and 4 factory adjusted to nominal Output #3 tracks #2 initial accuracy Line & Load Reg Outputs #1, 2, and 4 hold ±2% over AC input range and 0 to 100% load ENVIRONMENTAL Thermal Protection Shuts down power supply if overheated. Automatic recovery. Temperature Range 0°to 50°Catfullratings. Safety Agencies Most models are approved to UL1950 CSA #234 IEC 950 and TÜV EN60950, Class 1 SELV., CE 72/23/EEC/93/68EEC low voltage directive . Conducted RFI Meets FCC Part 15, Subpart J, Class A EN55022 Class B CISPR 22 Class B. Output Isolation Isolatedfrom ground 50 Vdc. Cooling Self-cooled by internal ball-bearing fan. OPTIONS Consult factory for available options. AC INPUT 90-264 VAC Continuous Range FUNCTION 115 VAC 230 VAC J1-21 |
More datasheets: 335104-12-0150 | 335104-12-0050 | KSM1131 | KSM1131ZLFG | RC1083BWHTWHTEF | RC1083BBLKBLKAF | 100ELT22MX | 100ELT22M | RMX-354-1205G | RMX-354-1224G |
Notice: we do not provide any warranties that information, datasheets, application notes, circuit diagrams, or software stored on this website are up-to-date or error free. The archived RMX-354-1212G Datasheet file may be downloaded here without warranties.