GPC40 Commercial/GPM40 Medical
Part | Datasheet |
---|---|
![]() |
GPC40B (pdf) |
Related Parts | Information |
---|---|
![]() |
GPC40D |
![]() |
GPC40-24 |
![]() |
GPM40A |
![]() |
GPM40-5 |
![]() |
GPM40-28 |
![]() |
GPM40-24 |
![]() |
GPM40-15 |
![]() |
GPC40A |
![]() |
GPC40-9 |
![]() |
GPM40B |
![]() |
GPC40-3.3 |
![]() |
GPC40-12 |
![]() |
GPM40-12 |
![]() |
GPC40-5 |
![]() |
GPC40-48G |
![]() |
GPC40-28G |
![]() |
GPC40-15G |
![]() |
GPC40BG |
![]() |
GPM40-24G |
![]() |
GPC40-9G |
![]() |
GPC40AG |
![]() |
GPC40-5G |
![]() |
GPC40-3.3G |
![]() |
GPC40-12G |
![]() |
GPC40-24G |
![]() |
GPC40DG |
PDF Datasheet Preview |
---|
GPC40 Commercial/GPM40 Medical 40 WATT GLOBAL PERFORMANCE SWITCHERS GLOBAL PERFORMANCE SWITCHERS Summary: • Wide-range ac input 85-264 Vac • 2-year warranty • Conducted EMI exceeds FCC Class B and CISPR 22 Class B Commercial models and CISPR 11 Class B Medical models • Single and multiple outputs • Commercial Approved to UL1950, EN60950 E3:2000 and CSA-C22.2 No. 234 • Medical Approved to UL2601-1, EN60601-1 and CSA22.2 No. 601 • Single and multiple outputs • RoHS compliant models available G suffix • marked to LVD DC Power Supplies SPECIFICATIONS Ac Input 85-264 Vac, 47-63 Hz single phase. Input Current Maximum input current at 120 Vac, 60 Hz with full rated output load A Hold-Up Time 20 ms minimum from loss of ac input at full load, nominal line 115 Vac . Output Power 40 W continuous, 50 W peak. Peak ratings are for 60 s maximum duration, 10% duty cycle. During peak load condition, output regulation may exceed total regulation limits. Overload Protection Fully protected against short circuit and output overload. Short circuit protection is cycling type power limit on outputs 1 & 2 foldback type on output Recovery after fault is automatic. See output ratings chart for additional notes or conditions. Overvoltage Protection. Main outputs 124% ± Efficiency 70% at full rated load, nominal input voltage, depending on model and load distribution. Turn-on Time Less than 1 second at 120 Vac, 25°C inversely proportional to input voltage and thermistor temperature . Input Protection Internal ac fuse provided. Designed to blow only if a catastrophic failure occurs in the unit. Inrush Current Inrush is limited by internal thermistors. Inrush at 240 Vac under cold start conditions will not exceed 34 A. Temperature Coefficient 0.03%/°C typical on all outputs. Environmental Designed for 0 to 50°C operation at full rated output power derate output current and total output power by per °C above 50°C. Output Noise rms, 1% pk-pk, 20 MHz bandwidth, differential mode. Measured with noise probe directly across output terminals of the power supply. Transient Response Main us typical response time for return to within of final value for a 50% load step change. A/us. Maximum voltage deviation is Startup/ shutdown overshoot less than Remote Sense Provided as a standard feature on single-output models. Voltage Adjustment Built-in potentiometer adjusts main output voltage EMI/EMC Compliance All models include built-in EMI filtering to meet the following emissions requirements: EMI SPECIFICATIONS Conducted Emissions Conducted Emissions Static Discharge RF Field Susceptibility Fast Transients/Bursts Surge Susceptibility Line Frequency Harmonics COMPLIANCE LEVEL EN55022 Class B FCC Class B EN55011 Class B FCC Class B EN61000-4-2, 6 kV contact, 8 kV air EN61000-4-3, 3 V/meter EN61000-4-4, 2 kV, 5 kH EN61000-4-5, 1 kV diff., 2 kV com. EN61000-3-2 Commercial Safety Approved to UL1950, CSA22.2 No. 950, IEC950, EN60950. All dc outputs are SELV under normal and single fault conditions. Medical Leakage Current The maximum leakage current is as follows: Test Condition Normal Single 120 Vac 60 Hz input 25 uA 264 Vac 60 Hz input 40 uA Fault 35 uA 60 uA Medical Safety Approved to UL2601-1, CSA22.2 No. 601 Level 3 and EN60601-1. UL file E116994 CSA #LR46516. The output s are intended for safety earthed Signal Output and Intermediate Circuits only. The output s are not acceptable for patient connection without additional isolation. All dc outputs are SELV under normal and single fault conditions. All specifications are typical at nominal input, full load at 25OC unless otherwise stated Commercial Model Medical Model |
More datasheets: 74ACTQ843SC | BB-BONE-CAM3-01 | 41-00005 | GPC40D | GPC40-24 | GPM40A | GPM40-5 | GPM40-28 | GPM40-24 | GPM40-15 |
Notice: we do not provide any warranties that information, datasheets, application notes, circuit diagrams, or software stored on this website are up-to-date or error free. The archived GPC40B Datasheet file may be downloaded here without warranties.